Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry
A viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department o...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2014-01-01
|
Series: | International Journal of Analytical Chemistry |
Online Access: | http://dx.doi.org/10.1155/2014/247316 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832550646987882496 |
---|---|
author | Caroline E. West Blaine N. Rhodes |
author_facet | Caroline E. West Blaine N. Rhodes |
author_sort | Caroline E. West |
collection | DOAJ |
description | A viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department of Health, Public Health Laboratories (PHL). 50 µL of urine was mixed with a 1 : 1 acetonitrile/water solution containing deuterated creatinine as the internal standard and then analyzed by LC/MS/MS. Utilizing electrospray ionization (ESI) in positive mode, the transition ions for creatinine and creatinine-d3 were determined to be 114.0 to 44.1 (quantifier), 114.0 to 86.1 (qualifier), and 117.0 to 47.1 (creatinine-d3). The retention time for creatinine was 0.85 minutes. The linear calibration range was 20–4000 mg/L, with a limit of detection at 1.77 mg/L and a limit of quantitation at 5.91 mg/L. LC/MS/MS and the colorimetric Jaffé reaction were associated significantly (Pearson r=0.9898 and R2=0.9797, ρ≤0.0001). The LC/MS/MS method developed at the PHL to determine creatinine in the spot urine samples had shorter retention times, and was more sensitive, reliable, reproducible, and safer than other LC/MS/MS or commercial methods such as the Jaffé reaction or modified versions thereof. |
format | Article |
id | doaj-art-a38858e1191a4285b837626209470f83 |
institution | Kabale University |
issn | 1687-8760 1687-8779 |
language | English |
publishDate | 2014-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Analytical Chemistry |
spelling | doaj-art-a38858e1191a4285b837626209470f832025-02-03T06:06:21ZengWileyInternational Journal of Analytical Chemistry1687-87601687-87792014-01-01201410.1155/2014/247316247316Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass SpectrometryCaroline E. West0Blaine N. Rhodes1The Washington State Department of Health, Public Health Laboratories, 1610 NE 150th Street, Shoreline, WA 98155, USAThe Washington State Department of Health, Public Health Laboratories, 1610 NE 150th Street, Shoreline, WA 98155, USAA viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department of Health, Public Health Laboratories (PHL). 50 µL of urine was mixed with a 1 : 1 acetonitrile/water solution containing deuterated creatinine as the internal standard and then analyzed by LC/MS/MS. Utilizing electrospray ionization (ESI) in positive mode, the transition ions for creatinine and creatinine-d3 were determined to be 114.0 to 44.1 (quantifier), 114.0 to 86.1 (qualifier), and 117.0 to 47.1 (creatinine-d3). The retention time for creatinine was 0.85 minutes. The linear calibration range was 20–4000 mg/L, with a limit of detection at 1.77 mg/L and a limit of quantitation at 5.91 mg/L. LC/MS/MS and the colorimetric Jaffé reaction were associated significantly (Pearson r=0.9898 and R2=0.9797, ρ≤0.0001). The LC/MS/MS method developed at the PHL to determine creatinine in the spot urine samples had shorter retention times, and was more sensitive, reliable, reproducible, and safer than other LC/MS/MS or commercial methods such as the Jaffé reaction or modified versions thereof.http://dx.doi.org/10.1155/2014/247316 |
spellingShingle | Caroline E. West Blaine N. Rhodes Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry International Journal of Analytical Chemistry |
title | Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry |
title_full | Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry |
title_fullStr | Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry |
title_full_unstemmed | Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry |
title_short | Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry |
title_sort | determination of urinary creatinine in washington state residents via liquid chromatography tandem mass spectrometry |
url | http://dx.doi.org/10.1155/2014/247316 |
work_keys_str_mv | AT carolineewest determinationofurinarycreatinineinwashingtonstateresidentsvialiquidchromatographytandemmassspectrometry AT blainenrhodes determinationofurinarycreatinineinwashingtonstateresidentsvialiquidchromatographytandemmassspectrometry |