Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions

Indoor air quality (IAQ) in higher education institutions’ dormitories, without mechanical ventilation, is a significant concern for students’ health due to prolonged occupancy in cold regions. The present investigation assessed IAQ by measuring two dormitories’ CO<sub>2</sub>, temperatu...

Full description

Saved in:
Bibliographic Details
Main Authors: Irfan Nasir, Husnain Haider, Md. Shafiquzzaman, Majed Alinizzi, Guangji Hu, Abdul Razzaq Ghumman
Format: Article
Language:English
Published: MDPI AG 2025-03-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/15/6/896
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849342306927247360
author Irfan Nasir
Husnain Haider
Md. Shafiquzzaman
Majed Alinizzi
Guangji Hu
Abdul Razzaq Ghumman
author_facet Irfan Nasir
Husnain Haider
Md. Shafiquzzaman
Majed Alinizzi
Guangji Hu
Abdul Razzaq Ghumman
author_sort Irfan Nasir
collection DOAJ
description Indoor air quality (IAQ) in higher education institutions’ dormitories, without mechanical ventilation, is a significant concern for students’ health due to prolonged occupancy in cold regions. The present investigation assessed IAQ by measuring two dormitories’ CO<sub>2</sub>, temperature, and relative humidity with the presence of one, two, three, and four occupants in the United Kingdom. Considering the possibility of natural ventilation by opening the windows in the summer, IAQ was monitored using two sensors located at 1 m and 2 m heights from the floor level of the dormitories in July. The tracer mass balance model showed close agreement with the monitored IAQ levels, with a direct relationship observed between occupant numbers and CO<sub>2</sub> build-up. CO<sub>2</sub> levels exceeded 1000 ppm within an hour during occupancy and closed ventilation, with air exchange rates between 0.12 and 0.2 h<sup>−1</sup>, increasing to 1334, 1259, 1884, and 2064 ppm after 30 min with one, two, three, and four occupants, respectively. Desired IAQ standards (1000 ppm) were achieved in 13, 33, 80, and 86 min for one, two, three, and four occupants after starting natural ventilation by opening 20% of the windows. The analysis of variance affirmed the effect of occupancy on IAQ, while the impact of height (1 m and 2 m) on CO<sub>2</sub> levels was insignificant. This study underscores the need to effectively ventilate the partial opening of windows in dormitories to mitigate CO<sub>2</sub> build-up, ensuring the desired ambient environment within dormitory rooms during summers in cold regions.
format Article
id doaj-art-a34f276b05dc4df9ba2532c1df39608b
institution Kabale University
issn 2075-5309
language English
publishDate 2025-03-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj-art-a34f276b05dc4df9ba2532c1df39608b2025-08-20T03:43:26ZengMDPI AGBuildings2075-53092025-03-0115689610.3390/buildings15060896Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold RegionsIrfan Nasir0Husnain Haider1Md. Shafiquzzaman2Majed Alinizzi3Guangji Hu4Abdul Razzaq Ghumman5Department of Civil Engineering, School of Engineering, University of Birmingham, Edgbaston, Birmingham B152TT, UKDepartment of Civil Engineering, College of Engineering, Qassim University, Buraydah 51452, Qassim, Saudi ArabiaDepartment of Civil Engineering, College of Engineering, Qassim University, Buraydah 51452, Qassim, Saudi ArabiaDepartment of Civil Engineering, College of Engineering, Qassim University, Buraydah 51452, Qassim, Saudi ArabiaSchool of Environment and Geography, Qingdao University, Qingdao 266071, ChinaDepartment of Civil Engineering, College of Engineering, Qassim University, Buraydah 51452, Qassim, Saudi ArabiaIndoor air quality (IAQ) in higher education institutions’ dormitories, without mechanical ventilation, is a significant concern for students’ health due to prolonged occupancy in cold regions. The present investigation assessed IAQ by measuring two dormitories’ CO<sub>2</sub>, temperature, and relative humidity with the presence of one, two, three, and four occupants in the United Kingdom. Considering the possibility of natural ventilation by opening the windows in the summer, IAQ was monitored using two sensors located at 1 m and 2 m heights from the floor level of the dormitories in July. The tracer mass balance model showed close agreement with the monitored IAQ levels, with a direct relationship observed between occupant numbers and CO<sub>2</sub> build-up. CO<sub>2</sub> levels exceeded 1000 ppm within an hour during occupancy and closed ventilation, with air exchange rates between 0.12 and 0.2 h<sup>−1</sup>, increasing to 1334, 1259, 1884, and 2064 ppm after 30 min with one, two, three, and four occupants, respectively. Desired IAQ standards (1000 ppm) were achieved in 13, 33, 80, and 86 min for one, two, three, and four occupants after starting natural ventilation by opening 20% of the windows. The analysis of variance affirmed the effect of occupancy on IAQ, while the impact of height (1 m and 2 m) on CO<sub>2</sub> levels was insignificant. This study underscores the need to effectively ventilate the partial opening of windows in dormitories to mitigate CO<sub>2</sub> build-up, ensuring the desired ambient environment within dormitory rooms during summers in cold regions.https://www.mdpi.com/2075-5309/15/6/896sensorsair qualitynumerical methodscarbon dioxidethermal stratificationcold regions
spellingShingle Irfan Nasir
Husnain Haider
Md. Shafiquzzaman
Majed Alinizzi
Guangji Hu
Abdul Razzaq Ghumman
Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions
Buildings
sensors
air quality
numerical methods
carbon dioxide
thermal stratification
cold regions
title Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions
title_full Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions
title_fullStr Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions
title_full_unstemmed Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions
title_short Investigating the Effects of Occupancy and Natural Ventilation on the Indoor Air Quality of Dormitories in Cold Regions
title_sort investigating the effects of occupancy and natural ventilation on the indoor air quality of dormitories in cold regions
topic sensors
air quality
numerical methods
carbon dioxide
thermal stratification
cold regions
url https://www.mdpi.com/2075-5309/15/6/896
work_keys_str_mv AT irfannasir investigatingtheeffectsofoccupancyandnaturalventilationontheindoorairqualityofdormitoriesincoldregions
AT husnainhaider investigatingtheeffectsofoccupancyandnaturalventilationontheindoorairqualityofdormitoriesincoldregions
AT mdshafiquzzaman investigatingtheeffectsofoccupancyandnaturalventilationontheindoorairqualityofdormitoriesincoldregions
AT majedalinizzi investigatingtheeffectsofoccupancyandnaturalventilationontheindoorairqualityofdormitoriesincoldregions
AT guangjihu investigatingtheeffectsofoccupancyandnaturalventilationontheindoorairqualityofdormitoriesincoldregions
AT abdulrazzaqghumman investigatingtheeffectsofoccupancyandnaturalventilationontheindoorairqualityofdormitoriesincoldregions