Simulation Analysis of Control Strategy for Three-phase Grid-connected Inverter Based on LLCL Filter
An active damping control strategy which formed current feedback of filter branch was proposed to effectively suppress the resonance of three-phase grid-connected inverter caused by LLCL filter. Compared with the simulative analysis of L filter and LCL filter, the superiority of LLCL filter and the...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Office of Control and Information Technology
2015-01-01
|
| Series: | Kongzhi Yu Xinxi Jishu |
| Subjects: | |
| Online Access: | http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2015.03.004 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849224817402707968 |
|---|---|
| author | LIU Haitao TANG Long |
| author_facet | LIU Haitao TANG Long |
| author_sort | LIU Haitao |
| collection | DOAJ |
| description | An active damping control strategy which formed current feedback of filter branch was proposed to effectively suppress
the resonance of three-phase grid-connected inverter caused by LLCL filter. Compared with the simulative analysis of L filter and LCL
filter, the superiority of LLCL filter and the effectiveness of its control strategy were proved. |
| format | Article |
| id | doaj-art-a2f0567d30ed477dac8490b91654d7f6 |
| institution | Kabale University |
| issn | 2096-5427 |
| language | zho |
| publishDate | 2015-01-01 |
| publisher | Editorial Office of Control and Information Technology |
| record_format | Article |
| series | Kongzhi Yu Xinxi Jishu |
| spelling | doaj-art-a2f0567d30ed477dac8490b91654d7f62025-08-25T06:54:13ZzhoEditorial Office of Control and Information TechnologyKongzhi Yu Xinxi Jishu2096-54272015-01-01151882327030Simulation Analysis of Control Strategy for Three-phase Grid-connected Inverter Based on LLCL FilterLIU HaitaoTANG LongAn active damping control strategy which formed current feedback of filter branch was proposed to effectively suppress the resonance of three-phase grid-connected inverter caused by LLCL filter. Compared with the simulative analysis of L filter and LCL filter, the superiority of LLCL filter and the effectiveness of its control strategy were proved.http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2015.03.004LLCL filtergrid-connected inverteractive damping |
| spellingShingle | LIU Haitao TANG Long Simulation Analysis of Control Strategy for Three-phase Grid-connected Inverter Based on LLCL Filter Kongzhi Yu Xinxi Jishu LLCL filter grid-connected inverter active damping |
| title | Simulation Analysis of Control Strategy for Three-phase
Grid-connected Inverter Based on LLCL Filter |
| title_full | Simulation Analysis of Control Strategy for Three-phase
Grid-connected Inverter Based on LLCL Filter |
| title_fullStr | Simulation Analysis of Control Strategy for Three-phase
Grid-connected Inverter Based on LLCL Filter |
| title_full_unstemmed | Simulation Analysis of Control Strategy for Three-phase
Grid-connected Inverter Based on LLCL Filter |
| title_short | Simulation Analysis of Control Strategy for Three-phase
Grid-connected Inverter Based on LLCL Filter |
| title_sort | simulation analysis of control strategy for three phase grid connected inverter based on llcl filter |
| topic | LLCL filter grid-connected inverter active damping |
| url | http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2015.03.004 |
| work_keys_str_mv | AT liuhaitao simulationanalysisofcontrolstrategyforthreephasegridconnectedinverterbasedonllclfilter AT tanglong simulationanalysisofcontrolstrategyforthreephasegridconnectedinverterbasedonllclfilter |