Adhesion test – testing of selected adhesives on fired clay

The following paper deals with the comparison of adhesion of specimens made of fired clay and selected adhesives. The adhesion was tested on specimens at the age of one, two and three days in order to determine the parameters of young masonry. Nine different adhesives (adhesives intended for masonry...

Full description

Saved in:
Bibliographic Details
Main Authors: Kristýna Richterová, Pavel Heinrich, Petr Bílý
Format: Article
Language:English
Published: Czech Technical University in Prague 2022-03-01
Series:Acta Polytechnica CTU Proceedings
Subjects:
Online Access:https://ojs.cvut.cz/ojs/index.php/APP/article/view/8114
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849408240331259904
author Kristýna Richterová
Pavel Heinrich
Petr Bílý
author_facet Kristýna Richterová
Pavel Heinrich
Petr Bílý
author_sort Kristýna Richterová
collection DOAJ
description The following paper deals with the comparison of adhesion of specimens made of fired clay and selected adhesives. The adhesion was tested on specimens at the age of one, two and three days in order to determine the parameters of young masonry. Nine different adhesives (adhesives intended for masonry and adhesives for others material) were tested in total. The above mentioned test is not standardized. The obtained results from the adhesion test determine the tensile strength between the adhesive and the fired clay and the adhesion of selected adhesive to the fired clay. The small specimens were made of two ceramic plates and an adhesive. Selected adhesives were applied to ceramic plates according to the usual standards. Eighty-one small specimens were produced in total – twenty-seven specimens for the adhesion test at each defined age of the specimens (one day, two days, three days). The produced specimens were cured in the climatic chamber with set laboratory conditions until the time of the test. The specimens were tested in the laboratory of the Heluz brick plant in Dolní Bukovsko. This paper deals with the procedure of preparation of the specimens, the course of the test and the comparison of gained results.
format Article
id doaj-art-a1d8ce6057d04c91bca152a5394f8698
institution Kabale University
issn 2336-5382
language English
publishDate 2022-03-01
publisher Czech Technical University in Prague
record_format Article
series Acta Polytechnica CTU Proceedings
spelling doaj-art-a1d8ce6057d04c91bca152a5394f86982025-08-20T03:35:50ZengCzech Technical University in PragueActa Polytechnica CTU Proceedings2336-53822022-03-0134859310.14311/APP.2022.34.00855354Adhesion test – testing of selected adhesives on fired clayKristýna Richterová0Pavel Heinrich1Petr Bílý2Czech Technical University in Prague, Faculty of Civil Engineering, Department of Concrete and Masonry Structures, Thákurova 7, 166 29 Prague 6, Czech RepublicCzech Technical University in Prague, Faculty of Civil Engineering, Department of Concrete and Masonry Structures, Thákurova 7, 166 29 Prague 6, Czech RepublicCzech Technical University in Prague, Faculty of Civil Engineering, Department of Concrete and Masonry Structures, Thákurova 7, 166 29 Prague 6, Czech RepublicThe following paper deals with the comparison of adhesion of specimens made of fired clay and selected adhesives. The adhesion was tested on specimens at the age of one, two and three days in order to determine the parameters of young masonry. Nine different adhesives (adhesives intended for masonry and adhesives for others material) were tested in total. The above mentioned test is not standardized. The obtained results from the adhesion test determine the tensile strength between the adhesive and the fired clay and the adhesion of selected adhesive to the fired clay. The small specimens were made of two ceramic plates and an adhesive. Selected adhesives were applied to ceramic plates according to the usual standards. Eighty-one small specimens were produced in total – twenty-seven specimens for the adhesion test at each defined age of the specimens (one day, two days, three days). The produced specimens were cured in the climatic chamber with set laboratory conditions until the time of the test. The specimens were tested in the laboratory of the Heluz brick plant in Dolní Bukovsko. This paper deals with the procedure of preparation of the specimens, the course of the test and the comparison of gained results.https://ojs.cvut.cz/ojs/index.php/APP/article/view/8114fired clayadhesion testadhesive
spellingShingle Kristýna Richterová
Pavel Heinrich
Petr Bílý
Adhesion test – testing of selected adhesives on fired clay
Acta Polytechnica CTU Proceedings
fired clay
adhesion test
adhesive
title Adhesion test – testing of selected adhesives on fired clay
title_full Adhesion test – testing of selected adhesives on fired clay
title_fullStr Adhesion test – testing of selected adhesives on fired clay
title_full_unstemmed Adhesion test – testing of selected adhesives on fired clay
title_short Adhesion test – testing of selected adhesives on fired clay
title_sort adhesion test testing of selected adhesives on fired clay
topic fired clay
adhesion test
adhesive
url https://ojs.cvut.cz/ojs/index.php/APP/article/view/8114
work_keys_str_mv AT kristynarichterova adhesiontesttestingofselectedadhesivesonfiredclay
AT pavelheinrich adhesiontesttestingofselectedadhesivesonfiredclay
AT petrbily adhesiontesttestingofselectedadhesivesonfiredclay