Micro-Angiographic Studies of End-to End Anastomosis of Femoral Artery in Rats*
Fifteen albino rats each weighing 300 to 400 gms were selected for micro angiographic studies. Microsurgical end-to-end femoral vein anastomosis was carried out and cream-o-bar 50% aqueous suspension was injected with the help of a D.K. Injector. A patency rate of 73% was achieved in the six week fo...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Thieme Medical and Scientific Publishers Pvt. Ltd.
1990-02-01
|
| Series: | Indian Journal of Plastic Surgery |
| Online Access: | http://www.thieme-connect.de/DOI/DOI?10.1055/s-0043-1774362 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850244129412349952 |
|---|---|
| author | F.M. Tripathi A.K. Chaudhury D.K. Rai |
| author_facet | F.M. Tripathi A.K. Chaudhury D.K. Rai |
| author_sort | F.M. Tripathi |
| collection | DOAJ |
| description | Fifteen albino rats each weighing 300 to 400 gms were selected for micro angiographic studies. Microsurgical end-to-end femoral vein anastomosis was carried out and cream-o-bar 50% aqueous suspension was injected with the help of a D.K. Injector. A patency rate of 73% was achieved in the six week follow up study. Results of angiographic changes observed in the vascular lumen following anastomosis have been analysed and are being presented. |
| format | Article |
| id | doaj-art-a1d23a9b1a094ba7ac4ed0fb514fa140 |
| institution | OA Journals |
| issn | 0970-0358 1998-376X |
| language | English |
| publishDate | 1990-02-01 |
| publisher | Thieme Medical and Scientific Publishers Pvt. Ltd. |
| record_format | Article |
| series | Indian Journal of Plastic Surgery |
| spelling | doaj-art-a1d23a9b1a094ba7ac4ed0fb514fa1402025-08-20T01:59:48ZengThieme Medical and Scientific Publishers Pvt. Ltd.Indian Journal of Plastic Surgery0970-03581998-376X1990-02-01230100901610.1055/s-0043-1774362Micro-Angiographic Studies of End-to End Anastomosis of Femoral Artery in Rats*F.M. TripathiA.K. ChaudhuryD.K. RaiFifteen albino rats each weighing 300 to 400 gms were selected for micro angiographic studies. Microsurgical end-to-end femoral vein anastomosis was carried out and cream-o-bar 50% aqueous suspension was injected with the help of a D.K. Injector. A patency rate of 73% was achieved in the six week follow up study. Results of angiographic changes observed in the vascular lumen following anastomosis have been analysed and are being presented.http://www.thieme-connect.de/DOI/DOI?10.1055/s-0043-1774362 |
| spellingShingle | F.M. Tripathi A.K. Chaudhury D.K. Rai Micro-Angiographic Studies of End-to End Anastomosis of Femoral Artery in Rats* Indian Journal of Plastic Surgery |
| title | Micro-Angiographic Studies of End-to End Anastomosis of Femoral Artery in Rats* |
| title_full | Micro-Angiographic Studies of End-to End Anastomosis of Femoral Artery in Rats* |
| title_fullStr | Micro-Angiographic Studies of End-to End Anastomosis of Femoral Artery in Rats* |
| title_full_unstemmed | Micro-Angiographic Studies of End-to End Anastomosis of Femoral Artery in Rats* |
| title_short | Micro-Angiographic Studies of End-to End Anastomosis of Femoral Artery in Rats* |
| title_sort | micro angiographic studies of end to end anastomosis of femoral artery in rats |
| url | http://www.thieme-connect.de/DOI/DOI?10.1055/s-0043-1774362 |
| work_keys_str_mv | AT fmtripathi microangiographicstudiesofendtoendanastomosisoffemoralarteryinrats AT akchaudhury microangiographicstudiesofendtoendanastomosisoffemoralarteryinrats AT dkrai microangiographicstudiesofendtoendanastomosisoffemoralarteryinrats |