Research on the Impact of Particulate Fouling Outdoor Heat Exchanger on the System Performance of the Residential Air Conditioner
This paper focused on the impact of outdoor heat exchanger polluted by atmospheric particulates on the system performance with the study object of 1.5 HP residential split-type air conditioner, and the fouling processes of copper tube-aluminum fin and aluminous microchannel heat exchangers were comp...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2016-01-01
|
| Series: | Zhileng xuebao |
| Subjects: | |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2016.05.087 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849707533735821312 |
|---|---|
| author | Shi Junye Chen Xiaoning Lu Bingqing Cai Bowei Xu Bo Chen Jiangping |
| author_facet | Shi Junye Chen Xiaoning Lu Bingqing Cai Bowei Xu Bo Chen Jiangping |
| author_sort | Shi Junye |
| collection | DOAJ |
| description | This paper focused on the impact of outdoor heat exchanger polluted by atmospheric particulates on the system performance with the study object of 1.5 HP residential split-type air conditioner, and the fouling processes of copper tube-aluminum fin and aluminous microchannel heat exchangers were compared. Two sets of units assembled with different outdoor heat exchangers were continuously running in the same atmospheric environment. Capacity, power consumption, discharge temperature ,condensing temperature and plugging ratio were tested to analyze the influence of atmospheric particulate pollution on the long-time performance. The results show that the plugging ratio of outdoor heat exchangers grows exponentially , the refrigerating capacity of the air conditioners assembled with cooper tube-aluminum fin and aluminous microchannel heat exchangers is decreased by 2.1% and 23.2%, power consumption is jumped by 6.2% and 34.6% and COP is decreased by 7.8% and 43.1%. Research problems and direction of long-term performance of aluminous microchannel heat exchangers in air conditioners are pointed out. |
| format | Article |
| id | doaj-art-a17590df27ec4ae3bf48d65eb8aa3f2b |
| institution | DOAJ |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2016-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-a17590df27ec4ae3bf48d65eb8aa3f2b2025-08-20T03:15:54ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392016-01-013766513266Research on the Impact of Particulate Fouling Outdoor Heat Exchanger on the System Performance of the Residential Air ConditionerShi JunyeChen XiaoningLu BingqingCai BoweiXu BoChen JiangpingThis paper focused on the impact of outdoor heat exchanger polluted by atmospheric particulates on the system performance with the study object of 1.5 HP residential split-type air conditioner, and the fouling processes of copper tube-aluminum fin and aluminous microchannel heat exchangers were compared. Two sets of units assembled with different outdoor heat exchangers were continuously running in the same atmospheric environment. Capacity, power consumption, discharge temperature ,condensing temperature and plugging ratio were tested to analyze the influence of atmospheric particulate pollution on the long-time performance. The results show that the plugging ratio of outdoor heat exchangers grows exponentially , the refrigerating capacity of the air conditioners assembled with cooper tube-aluminum fin and aluminous microchannel heat exchangers is decreased by 2.1% and 23.2%, power consumption is jumped by 6.2% and 34.6% and COP is decreased by 7.8% and 43.1%. Research problems and direction of long-term performance of aluminous microchannel heat exchangers in air conditioners are pointed out.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2016.05.087heat exchangerlong-term performanceatmospheric particulatesplugging |
| spellingShingle | Shi Junye Chen Xiaoning Lu Bingqing Cai Bowei Xu Bo Chen Jiangping Research on the Impact of Particulate Fouling Outdoor Heat Exchanger on the System Performance of the Residential Air Conditioner Zhileng xuebao heat exchanger long-term performance atmospheric particulates plugging |
| title | Research on the Impact of Particulate Fouling Outdoor Heat Exchanger on the System Performance of the Residential Air Conditioner |
| title_full | Research on the Impact of Particulate Fouling Outdoor Heat Exchanger on the System Performance of the Residential Air Conditioner |
| title_fullStr | Research on the Impact of Particulate Fouling Outdoor Heat Exchanger on the System Performance of the Residential Air Conditioner |
| title_full_unstemmed | Research on the Impact of Particulate Fouling Outdoor Heat Exchanger on the System Performance of the Residential Air Conditioner |
| title_short | Research on the Impact of Particulate Fouling Outdoor Heat Exchanger on the System Performance of the Residential Air Conditioner |
| title_sort | research on the impact of particulate fouling outdoor heat exchanger on the system performance of the residential air conditioner |
| topic | heat exchanger long-term performance atmospheric particulates plugging |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2016.05.087 |
| work_keys_str_mv | AT shijunye researchontheimpactofparticulatefoulingoutdoorheatexchangeronthesystemperformanceoftheresidentialairconditioner AT chenxiaoning researchontheimpactofparticulatefoulingoutdoorheatexchangeronthesystemperformanceoftheresidentialairconditioner AT lubingqing researchontheimpactofparticulatefoulingoutdoorheatexchangeronthesystemperformanceoftheresidentialairconditioner AT caibowei researchontheimpactofparticulatefoulingoutdoorheatexchangeronthesystemperformanceoftheresidentialairconditioner AT xubo researchontheimpactofparticulatefoulingoutdoorheatexchangeronthesystemperformanceoftheresidentialairconditioner AT chenjiangping researchontheimpactofparticulatefoulingoutdoorheatexchangeronthesystemperformanceoftheresidentialairconditioner |