Features of Accounting for Geometric and Physical Nonlinearities in Long-Span Pneumatic Membrane Systems

Objective. The purpose of the study is to substantiate the need to take into account the geometric and physical nonlinearities in large-span membrane-pneumatic systems.Method. The study is based on the application of the parameter variation method; method of successive loadings; the iterative method...

Full description

Saved in:
Bibliographic Details
Main Authors: A. Yu. Kim, S. V. Polnikov, M. F. Amoyan
Format: Article
Language:Russian
Published: Dagestan State Technical University 2023-02-01
Series:Вестник Дагестанского государственного технического университета: Технические науки
Subjects:
Online Access:https://vestnik.dgtu.ru/jour/article/view/1189
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849250180114677760
author A. Yu. Kim
S. V. Polnikov
M. F. Amoyan
author_facet A. Yu. Kim
S. V. Polnikov
M. F. Amoyan
author_sort A. Yu. Kim
collection DOAJ
description Objective. The purpose of the study is to substantiate the need to take into account the geometric and physical nonlinearities in large-span membrane-pneumatic systems.Method. The study is based on the application of the parameter variation method; method of successive loadings; the iterative method of parameter increments using the third Euler-Cauchy numerical procedure or the Runge-Kutta method of a higher order of accuracy.Result. It has been established that the geometric non-linearity can be from 5 to 10% if the structure has a small or medium span, and the load on the structure is not very large, especially when it comes to section load. If the span of the structure is 120150 meters, and the load and deflections are large enough, then the geometric nonlinearity can be 20% or more. It was revealed that the physical nonlinearity, which we took into account by the standard Euler-Cauchy procedure of the third order of accuracy, with a large span of the structure and a large load is approximately 13-21%, and the part of the physical nonlinearity of the air pumped between the hermetic membranes of the structure is determined using an improved formula Euler-Cauchy with the number of iterations 20-25, i.e. "aftereffect", according to the results of the study, ranges from 2-7%.Conclusion. A structure consisting of light metal structures can be erected within a few months on a finished pile or strip foundation. Such structures can easily withstand many types of dynamic loads, namely wind, seismic, vibration, and are one-third cheaper than buildings made from traditional materials.
format Article
id doaj-art-a158f660b3624a8bb2be660d3bf3a86b
institution Kabale University
issn 2073-6185
2542-095X
language Russian
publishDate 2023-02-01
publisher Dagestan State Technical University
record_format Article
series Вестник Дагестанского государственного технического университета: Технические науки
spelling doaj-art-a158f660b3624a8bb2be660d3bf3a86b2025-08-20T03:57:21ZrusDagestan State Technical UniversityВестник Дагестанского государственного технического университета: Технические науки2073-61852542-095X2023-02-0149415216110.21822/2073-6185-2022-49-4-152-161747Features of Accounting for Geometric and Physical Nonlinearities in Long-Span Pneumatic Membrane SystemsA. Yu. Kim0S. V. Polnikov1M. F. Amoyan2Yu.A. Gagarin Saratov State Technical UniversityYu.A. Gagarin Saratov State Technical UniversityYu.A. Gagarin Saratov State Technical UniversityObjective. The purpose of the study is to substantiate the need to take into account the geometric and physical nonlinearities in large-span membrane-pneumatic systems.Method. The study is based on the application of the parameter variation method; method of successive loadings; the iterative method of parameter increments using the third Euler-Cauchy numerical procedure or the Runge-Kutta method of a higher order of accuracy.Result. It has been established that the geometric non-linearity can be from 5 to 10% if the structure has a small or medium span, and the load on the structure is not very large, especially when it comes to section load. If the span of the structure is 120150 meters, and the load and deflections are large enough, then the geometric nonlinearity can be 20% or more. It was revealed that the physical nonlinearity, which we took into account by the standard Euler-Cauchy procedure of the third order of accuracy, with a large span of the structure and a large load is approximately 13-21%, and the part of the physical nonlinearity of the air pumped between the hermetic membranes of the structure is determined using an improved formula Euler-Cauchy with the number of iterations 20-25, i.e. "aftereffect", according to the results of the study, ranges from 2-7%.Conclusion. A structure consisting of light metal structures can be erected within a few months on a finished pile or strip foundation. Such structures can easily withstand many types of dynamic loads, namely wind, seismic, vibration, and are one-third cheaper than buildings made from traditional materials.https://vestnik.dgtu.ru/jour/article/view/1189non-linear building mechanicsstep-by-step methods for solving problemscalculation of a structure taking into account geometric and physical nonlinearityiterative euler-cauchy method of the third order of accuracy
spellingShingle A. Yu. Kim
S. V. Polnikov
M. F. Amoyan
Features of Accounting for Geometric and Physical Nonlinearities in Long-Span Pneumatic Membrane Systems
Вестник Дагестанского государственного технического университета: Технические науки
non-linear building mechanics
step-by-step methods for solving problems
calculation of a structure taking into account geometric and physical nonlinearity
iterative euler-cauchy method of the third order of accuracy
title Features of Accounting for Geometric and Physical Nonlinearities in Long-Span Pneumatic Membrane Systems
title_full Features of Accounting for Geometric and Physical Nonlinearities in Long-Span Pneumatic Membrane Systems
title_fullStr Features of Accounting for Geometric and Physical Nonlinearities in Long-Span Pneumatic Membrane Systems
title_full_unstemmed Features of Accounting for Geometric and Physical Nonlinearities in Long-Span Pneumatic Membrane Systems
title_short Features of Accounting for Geometric and Physical Nonlinearities in Long-Span Pneumatic Membrane Systems
title_sort features of accounting for geometric and physical nonlinearities in long span pneumatic membrane systems
topic non-linear building mechanics
step-by-step methods for solving problems
calculation of a structure taking into account geometric and physical nonlinearity
iterative euler-cauchy method of the third order of accuracy
url https://vestnik.dgtu.ru/jour/article/view/1189
work_keys_str_mv AT ayukim featuresofaccountingforgeometricandphysicalnonlinearitiesinlongspanpneumaticmembranesystems
AT svpolnikov featuresofaccountingforgeometricandphysicalnonlinearitiesinlongspanpneumaticmembranesystems
AT mfamoyan featuresofaccountingforgeometricandphysicalnonlinearitiesinlongspanpneumaticmembranesystems