Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis Approach

Total hip arthroplasty (THA) is a widely performed procedure to restore hip function in patients with degenerative joint diseases. Traditional “press-fit” fixation methods rely on sufficient bone quality for stability, but additional screw fixation is often necessary for patients with suboptimal bon...

Full description

Saved in:
Bibliographic Details
Main Authors: Jacob Stroud, Emily T. Yan, Jacob Anthony, Kyle Walker, Chung-Hyun Goh
Format: Article
Language:English
Published: MDPI AG 2025-03-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/15/7/3722
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850212912736501760
author Jacob Stroud
Emily T. Yan
Jacob Anthony
Kyle Walker
Chung-Hyun Goh
author_facet Jacob Stroud
Emily T. Yan
Jacob Anthony
Kyle Walker
Chung-Hyun Goh
author_sort Jacob Stroud
collection DOAJ
description Total hip arthroplasty (THA) is a widely performed procedure to restore hip function in patients with degenerative joint diseases. Traditional “press-fit” fixation methods rely on sufficient bone quality for stability, but additional screw fixation is often necessary for patients with suboptimal bone conditions. However, comprehensive studies utilizing predictive modeling to optimize screw placement strategies in THA remain limited. This study integrates finite element analysis (FEA) with deep learning (DL) to optimize screw fixation strategies, enhancing implant stability and reducing revision rates. The design optimization process was conducted to refine key implant parameters before training the deep learning surrogate model. By utilizing advanced simulation techniques—including Goodness of Fit analysis, Response Graphs, Local Sensitivity Analysis, and Spider Charts—critical factors influencing stress distribution and fixation stability were identified. The optimization process ensured that the dataset used for deep learning training consisted of well-validated simulations, thereby improving the predictive accuracy of stress–strain responses. The findings indicate that optimized screw placement significantly improves load distribution, reducing stress concentrations and enhancing long-term implant stability. The comparative analysis of FEA and DL results showed that the DL-FEA surrogate model successfully replicated deformation patterns, though with a mean squared error (MSE) of 24.06%. While this suggests room for improvement, the model demonstrates potential for streamlining surgical planning. A comparative assessment with traditional methods highlights the advantages of DL-FEA in reducing computational time while maintaining precision. Future improvements will focus on refining the DL model, increasing the dataset size, and incorporating clinical validation. These findings contribute to developing a computational protocol for personalized acetabular cup fixation, with implications for reducing revision rates and improving surgical outcomes.
format Article
id doaj-art-a09f6502dcf54783baad8d8001d8cb5b
institution OA Journals
issn 2076-3417
language English
publishDate 2025-03-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj-art-a09f6502dcf54783baad8d8001d8cb5b2025-08-20T02:09:14ZengMDPI AGApplied Sciences2076-34172025-03-01157372210.3390/app15073722Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis ApproachJacob Stroud0Emily T. Yan1Jacob Anthony2Kyle Walker3Chung-Hyun Goh4Department of Mechanical Engineering, University of Texas at Tyler, Tyler, TX 75799, USACalifornia Health Sciences University College of Osteopathic Medicine, Clovis, CA 93611, USADepartment of Mechanical Engineering, University of Texas at Tyler, Tyler, TX 75799, USADepartment of Orthopaedic Surgery, University of California-Davis, Sacramento, CA 95817, USADepartment of Mechanical Engineering, University of Texas at Tyler, Tyler, TX 75799, USATotal hip arthroplasty (THA) is a widely performed procedure to restore hip function in patients with degenerative joint diseases. Traditional “press-fit” fixation methods rely on sufficient bone quality for stability, but additional screw fixation is often necessary for patients with suboptimal bone conditions. However, comprehensive studies utilizing predictive modeling to optimize screw placement strategies in THA remain limited. This study integrates finite element analysis (FEA) with deep learning (DL) to optimize screw fixation strategies, enhancing implant stability and reducing revision rates. The design optimization process was conducted to refine key implant parameters before training the deep learning surrogate model. By utilizing advanced simulation techniques—including Goodness of Fit analysis, Response Graphs, Local Sensitivity Analysis, and Spider Charts—critical factors influencing stress distribution and fixation stability were identified. The optimization process ensured that the dataset used for deep learning training consisted of well-validated simulations, thereby improving the predictive accuracy of stress–strain responses. The findings indicate that optimized screw placement significantly improves load distribution, reducing stress concentrations and enhancing long-term implant stability. The comparative analysis of FEA and DL results showed that the DL-FEA surrogate model successfully replicated deformation patterns, though with a mean squared error (MSE) of 24.06%. While this suggests room for improvement, the model demonstrates potential for streamlining surgical planning. A comparative assessment with traditional methods highlights the advantages of DL-FEA in reducing computational time while maintaining precision. Future improvements will focus on refining the DL model, increasing the dataset size, and incorporating clinical validation. These findings contribute to developing a computational protocol for personalized acetabular cup fixation, with implications for reducing revision rates and improving surgical outcomes.https://www.mdpi.com/2076-3417/15/7/3722deep learningmachine learningfinite element analysisdesign optimizationtotal hip arthroplastyjoint
spellingShingle Jacob Stroud
Emily T. Yan
Jacob Anthony
Kyle Walker
Chung-Hyun Goh
Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis Approach
Applied Sciences
deep learning
machine learning
finite element analysis
design optimization
total hip arthroplasty
joint
title Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis Approach
title_full Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis Approach
title_fullStr Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis Approach
title_full_unstemmed Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis Approach
title_short Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis Approach
title_sort optimizing screw fixation in total hip arthroplasty a deep learning and finite element analysis approach
topic deep learning
machine learning
finite element analysis
design optimization
total hip arthroplasty
joint
url https://www.mdpi.com/2076-3417/15/7/3722
work_keys_str_mv AT jacobstroud optimizingscrewfixationintotalhiparthroplastyadeeplearningandfiniteelementanalysisapproach
AT emilytyan optimizingscrewfixationintotalhiparthroplastyadeeplearningandfiniteelementanalysisapproach
AT jacobanthony optimizingscrewfixationintotalhiparthroplastyadeeplearningandfiniteelementanalysisapproach
AT kylewalker optimizingscrewfixationintotalhiparthroplastyadeeplearningandfiniteelementanalysisapproach
AT chunghyungoh optimizingscrewfixationintotalhiparthroplastyadeeplearningandfiniteelementanalysisapproach