The Development and Application of a Three-Dimensional Corona Discharge Numerical Model Considering the Thunderstorm Electric Field Polarity Reversal Process

The study of the ground tip corona discharge is an important part of the lightning strike mechanism and lightning warning research. Because the characteristics of the corona charge distribution are difficult to observe directly, simulation research is indispensable. However, most of the previous mod...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhaoxia Wang, Bin Wu, Xiufeng Guo, Nian Zhao, He Zhang, Yubin Zhao, Yuhang Zheng
Format: Article
Language:English
Published: MDPI AG 2025-05-01
Series:Atmosphere
Subjects:
Online Access:https://www.mdpi.com/2073-4433/16/5/612
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The study of the ground tip corona discharge is an important part of the lightning strike mechanism and lightning warning research. Because the characteristics of the corona charge distribution are difficult to observe directly, simulation research is indispensable. However, most of the previous models have been unipolar models, which cannot reflect the characteristics of the tip corona discharge under electric field reversal during real thunderstorms. Therefore, the development of three-dimensional positive and negative corona discharge models is of great significance. In this study, a three-dimensional corona discharge numerical model considering the polarity reversal process of the electric field was developed with or without a wind field and simulated the tip corona discharge characteristics under this reversal. The reliability of the model was verified by comparing the observed results. Compared with the unipolar corona discharge model, this model could effectively evaluate the impact of the first half-cycle corona discharge on the second half-cycle opposite-polarity corona discharge and invert the spatial separation distribution characteristics of different polar corona charges released in both cycles under the influence of wind and the spatial electric field distribution characteristics generated by the corresponding corona charges. Comparing unipolar corona discharges under the same wave pattern and amplitude of the background electric field, it was assumed that the unipolar corona discharge occurred in the half cycle after the polarity reversal of an electric field, and there was also an opposite-polarity corona discharge process before it. Due to the influence of the first half cycle, the background electric field required for a corona discharge was smaller, and the corona current was generated earlier, but the end time was equivalent. At the same time, due to the neutralization effect of positive and negative corona charges, the peak value of the total corona charge in the second half cycle was significantly smaller than that of the unipolar model. At different building heights, the peak difference in the corona current and the peak difference in the corona charge between the two models increased linearly with an increase in height. It could be seen that this model had better simulation results and wider application value.
ISSN:2073-4433