EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT

The prosthesis ON-X carcas has advantages in implantation commodity and safety, effective orifice area. We pe- sent results of this prosthesis usage during perioud of 2006–2009 years. This time 792 operations with AC were completed. In mitral position were implanted 132 (91,7%) prostheses ON-X. Of t...

Full description

Saved in:
Bibliographic Details
Main Authors: M. A. Sazonenkov, D. A. Basarab, S. S. Krivorot, M. N. Korneluk
Format: Article
Language:Russian
Published: Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov 2010-06-01
Series:Вестник трансплантологии и искусственных органов
Subjects:
Online Access:https://journal.transpl.ru/vtio/article/view/343
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849691139549954048
author M. A. Sazonenkov
D. A. Basarab
S. S. Krivorot
M. N. Korneluk
author_facet M. A. Sazonenkov
D. A. Basarab
S. S. Krivorot
M. N. Korneluk
author_sort M. A. Sazonenkov
collection DOAJ
description The prosthesis ON-X carcas has advantages in implantation commodity and safety, effective orifice area. We pe- sent results of this prosthesis usage during perioud of 2006–2009 years. This time 792 operations with AC were completed. In mitral position were implanted 132 (91,7%) prostheses ON-X. Of them 80 (60,6%) valves were sutured with complete or partial preservation of posterior leaflet and 26 (19,7%) valves – with total MV preser- vation. In aortic position we implanted 76 (53,9%) valves ON-X. Only 3 cases needed posterior aortoplasty for the N 23 prosthesis implantation. In perioperative and late postoperative periods we didn’t meet prostheses thrombosis or dysfunction. Reoperati- ons for high prosthesis gradients didn’t occur in postoperative period. Late postoperatively there were 3 (1,1%) cases of embolic events related to the incorrect anticoagulant treatment.
format Article
id doaj-art-9f7cdda7dcc84360bebce7f018d2ced8
institution DOAJ
issn 1995-1191
language Russian
publishDate 2010-06-01
publisher Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
record_format Article
series Вестник трансплантологии и искусственных органов
spelling doaj-art-9f7cdda7dcc84360bebce7f018d2ced82025-08-20T03:21:07ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.ShumakovВестник трансплантологии и искусственных органов1995-11912010-06-01124394310.15825/1995-1191-2010-4-39-43286EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENTM. A. Sazonenkov0D. A. Basarab1S. S. Krivorot2M. N. Korneluk3Regional clinical Hospital, BelgorodRegional clinical Hospital, BelgorodRegional clinical Hospital, BelgorodRegional clinical Hospital, BelgorodThe prosthesis ON-X carcas has advantages in implantation commodity and safety, effective orifice area. We pe- sent results of this prosthesis usage during perioud of 2006–2009 years. This time 792 operations with AC were completed. In mitral position were implanted 132 (91,7%) prostheses ON-X. Of them 80 (60,6%) valves were sutured with complete or partial preservation of posterior leaflet and 26 (19,7%) valves – with total MV preser- vation. In aortic position we implanted 76 (53,9%) valves ON-X. Only 3 cases needed posterior aortoplasty for the N 23 prosthesis implantation. In perioperative and late postoperative periods we didn’t meet prostheses thrombosis or dysfunction. Reoperati- ons for high prosthesis gradients didn’t occur in postoperative period. Late postoperatively there were 3 (1,1%) cases of embolic events related to the incorrect anticoagulant treatment.https://journal.transpl.ru/vtio/article/view/343mechanic heart valve prostheseslate resultsvalve on-x.
spellingShingle M. A. Sazonenkov
D. A. Basarab
S. S. Krivorot
M. N. Korneluk
EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT
Вестник трансплантологии и искусственных органов
mechanic heart valve prostheses
late results
valve on-x.
title EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT
title_full EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT
title_fullStr EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT
title_full_unstemmed EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT
title_short EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT
title_sort experience with in on x prosthesis in heart valve replacement
topic mechanic heart valve prostheses
late results
valve on-x.
url https://journal.transpl.ru/vtio/article/view/343
work_keys_str_mv AT masazonenkov experiencewithinonxprosthesisinheartvalvereplacement
AT dabasarab experiencewithinonxprosthesisinheartvalvereplacement
AT sskrivorot experiencewithinonxprosthesisinheartvalvereplacement
AT mnkorneluk experiencewithinonxprosthesisinheartvalvereplacement