EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT
The prosthesis ON-X carcas has advantages in implantation commodity and safety, effective orifice area. We pe- sent results of this prosthesis usage during perioud of 2006–2009 years. This time 792 operations with AC were completed. In mitral position were implanted 132 (91,7%) prostheses ON-X. Of t...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | Russian |
| Published: |
Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
2010-06-01
|
| Series: | Вестник трансплантологии и искусственных органов |
| Subjects: | |
| Online Access: | https://journal.transpl.ru/vtio/article/view/343 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849691139549954048 |
|---|---|
| author | M. A. Sazonenkov D. A. Basarab S. S. Krivorot M. N. Korneluk |
| author_facet | M. A. Sazonenkov D. A. Basarab S. S. Krivorot M. N. Korneluk |
| author_sort | M. A. Sazonenkov |
| collection | DOAJ |
| description | The prosthesis ON-X carcas has advantages in implantation commodity and safety, effective orifice area. We pe- sent results of this prosthesis usage during perioud of 2006–2009 years. This time 792 operations with AC were completed. In mitral position were implanted 132 (91,7%) prostheses ON-X. Of them 80 (60,6%) valves were sutured with complete or partial preservation of posterior leaflet and 26 (19,7%) valves – with total MV preser- vation. In aortic position we implanted 76 (53,9%) valves ON-X. Only 3 cases needed posterior aortoplasty for the N 23 prosthesis implantation. In perioperative and late postoperative periods we didn’t meet prostheses thrombosis or dysfunction. Reoperati- ons for high prosthesis gradients didn’t occur in postoperative period. Late postoperatively there were 3 (1,1%) cases of embolic events related to the incorrect anticoagulant treatment. |
| format | Article |
| id | doaj-art-9f7cdda7dcc84360bebce7f018d2ced8 |
| institution | DOAJ |
| issn | 1995-1191 |
| language | Russian |
| publishDate | 2010-06-01 |
| publisher | Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov |
| record_format | Article |
| series | Вестник трансплантологии и искусственных органов |
| spelling | doaj-art-9f7cdda7dcc84360bebce7f018d2ced82025-08-20T03:21:07ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.ShumakovВестник трансплантологии и искусственных органов1995-11912010-06-01124394310.15825/1995-1191-2010-4-39-43286EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENTM. A. Sazonenkov0D. A. Basarab1S. S. Krivorot2M. N. Korneluk3Regional clinical Hospital, BelgorodRegional clinical Hospital, BelgorodRegional clinical Hospital, BelgorodRegional clinical Hospital, BelgorodThe prosthesis ON-X carcas has advantages in implantation commodity and safety, effective orifice area. We pe- sent results of this prosthesis usage during perioud of 2006–2009 years. This time 792 operations with AC were completed. In mitral position were implanted 132 (91,7%) prostheses ON-X. Of them 80 (60,6%) valves were sutured with complete or partial preservation of posterior leaflet and 26 (19,7%) valves – with total MV preser- vation. In aortic position we implanted 76 (53,9%) valves ON-X. Only 3 cases needed posterior aortoplasty for the N 23 prosthesis implantation. In perioperative and late postoperative periods we didn’t meet prostheses thrombosis or dysfunction. Reoperati- ons for high prosthesis gradients didn’t occur in postoperative period. Late postoperatively there were 3 (1,1%) cases of embolic events related to the incorrect anticoagulant treatment.https://journal.transpl.ru/vtio/article/view/343mechanic heart valve prostheseslate resultsvalve on-x. |
| spellingShingle | M. A. Sazonenkov D. A. Basarab S. S. Krivorot M. N. Korneluk EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT Вестник трансплантологии и искусственных органов mechanic heart valve prostheses late results valve on-x. |
| title | EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT |
| title_full | EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT |
| title_fullStr | EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT |
| title_full_unstemmed | EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT |
| title_short | EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT |
| title_sort | experience with in on x prosthesis in heart valve replacement |
| topic | mechanic heart valve prostheses late results valve on-x. |
| url | https://journal.transpl.ru/vtio/article/view/343 |
| work_keys_str_mv | AT masazonenkov experiencewithinonxprosthesisinheartvalvereplacement AT dabasarab experiencewithinonxprosthesisinheartvalvereplacement AT sskrivorot experiencewithinonxprosthesisinheartvalvereplacement AT mnkorneluk experiencewithinonxprosthesisinheartvalvereplacement |