Determination of Antioxidant 264 in the Butyl Rubber Stopper and the Compatibility with Recombinant Potent Antitumor and Antivirus Protein Injection

Objective. To establish a method for extraction and determination of antioxidant 264 (2,6-di-tert-butyl-4-methylphenol) in the brominated butyl rubber stopper for injection and migration study in recombinant potent antitumor and antivirus protein injection (Novaferon). Methods. Dichloromethane-ethan...

Full description

Saved in:
Bibliographic Details
Main Authors: Min Zhao, Xianhui Li, Di Zhang, Longshan Zhao
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Journal of Analytical Methods in Chemistry
Online Access:http://dx.doi.org/10.1155/2020/8827925
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832566425635520512
author Min Zhao
Xianhui Li
Di Zhang
Longshan Zhao
author_facet Min Zhao
Xianhui Li
Di Zhang
Longshan Zhao
author_sort Min Zhao
collection DOAJ
description Objective. To establish a method for extraction and determination of antioxidant 264 (2,6-di-tert-butyl-4-methylphenol) in the brominated butyl rubber stopper for injection and migration study in recombinant potent antitumor and antivirus protein injection (Novaferon). Methods. Dichloromethane-ethanol was adopted as the extraction solvent during the process of reflux extraction of antioxidant 264 in the brominated butyl rubber stopper. High-performance liquid chromatography (HPLC) was used for the determination of the migration of antioxidant 264 to Novaferon. The mobile phase consisted of acetonitrile-water (80 : 20, v/v). The flow rate was 1.5 mL/min. The detection wavelength was 280 nm. Results. The linearity range was from 4.003 to 200.150 μg/mL (r2 = 0.99996), and the average recovery of antioxidant 264 was 97.8%. The applicability of the methodology was good, which can be used for the determination of antioxidant 264. The results indicated that antioxidant 264 was not detected in Novaferon after the accelerated test and three months of long-term test. Conclusion. The established validated method in this study can be used for the determination of antioxidant 264 in the rubber stopper, and the brominated butyl rubber stopper has good compatibility with Novaferon.
format Article
id doaj-art-9dd07cdea6b64d21ae9b4e949cce028a
institution Kabale University
issn 2090-8865
2090-8873
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series Journal of Analytical Methods in Chemistry
spelling doaj-art-9dd07cdea6b64d21ae9b4e949cce028a2025-02-03T01:04:08ZengWileyJournal of Analytical Methods in Chemistry2090-88652090-88732020-01-01202010.1155/2020/88279258827925Determination of Antioxidant 264 in the Butyl Rubber Stopper and the Compatibility with Recombinant Potent Antitumor and Antivirus Protein InjectionMin Zhao0Xianhui Li1Di Zhang2Longshan Zhao3School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, ChinaSchool of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, ChinaShenyang Wellwolf Pharmaceutical Science and Technology Co. Ltd., Shenyang 110022, ChinaSchool of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, ChinaObjective. To establish a method for extraction and determination of antioxidant 264 (2,6-di-tert-butyl-4-methylphenol) in the brominated butyl rubber stopper for injection and migration study in recombinant potent antitumor and antivirus protein injection (Novaferon). Methods. Dichloromethane-ethanol was adopted as the extraction solvent during the process of reflux extraction of antioxidant 264 in the brominated butyl rubber stopper. High-performance liquid chromatography (HPLC) was used for the determination of the migration of antioxidant 264 to Novaferon. The mobile phase consisted of acetonitrile-water (80 : 20, v/v). The flow rate was 1.5 mL/min. The detection wavelength was 280 nm. Results. The linearity range was from 4.003 to 200.150 μg/mL (r2 = 0.99996), and the average recovery of antioxidant 264 was 97.8%. The applicability of the methodology was good, which can be used for the determination of antioxidant 264. The results indicated that antioxidant 264 was not detected in Novaferon after the accelerated test and three months of long-term test. Conclusion. The established validated method in this study can be used for the determination of antioxidant 264 in the rubber stopper, and the brominated butyl rubber stopper has good compatibility with Novaferon.http://dx.doi.org/10.1155/2020/8827925
spellingShingle Min Zhao
Xianhui Li
Di Zhang
Longshan Zhao
Determination of Antioxidant 264 in the Butyl Rubber Stopper and the Compatibility with Recombinant Potent Antitumor and Antivirus Protein Injection
Journal of Analytical Methods in Chemistry
title Determination of Antioxidant 264 in the Butyl Rubber Stopper and the Compatibility with Recombinant Potent Antitumor and Antivirus Protein Injection
title_full Determination of Antioxidant 264 in the Butyl Rubber Stopper and the Compatibility with Recombinant Potent Antitumor and Antivirus Protein Injection
title_fullStr Determination of Antioxidant 264 in the Butyl Rubber Stopper and the Compatibility with Recombinant Potent Antitumor and Antivirus Protein Injection
title_full_unstemmed Determination of Antioxidant 264 in the Butyl Rubber Stopper and the Compatibility with Recombinant Potent Antitumor and Antivirus Protein Injection
title_short Determination of Antioxidant 264 in the Butyl Rubber Stopper and the Compatibility with Recombinant Potent Antitumor and Antivirus Protein Injection
title_sort determination of antioxidant 264 in the butyl rubber stopper and the compatibility with recombinant potent antitumor and antivirus protein injection
url http://dx.doi.org/10.1155/2020/8827925
work_keys_str_mv AT minzhao determinationofantioxidant264inthebutylrubberstopperandthecompatibilitywithrecombinantpotentantitumorandantivirusproteininjection
AT xianhuili determinationofantioxidant264inthebutylrubberstopperandthecompatibilitywithrecombinantpotentantitumorandantivirusproteininjection
AT dizhang determinationofantioxidant264inthebutylrubberstopperandthecompatibilitywithrecombinantpotentantitumorandantivirusproteininjection
AT longshanzhao determinationofantioxidant264inthebutylrubberstopperandthecompatibilitywithrecombinantpotentantitumorandantivirusproteininjection