The Clinical Utility of the Seated Wall Angel as a Test with Scoring

# Background The seated wall angel (SWA) is an intervention to improve upper quarter mobility but has not been described as a clinical test with scoring. # Hypothesis/ Purpose To explore the clinical utility of the SWA as a test with scoring. The authors hypothesized that SWA test scores would b...

Full description

Saved in:
Bibliographic Details
Main Authors: Chad Kofoed, Allison Palmsten, Jonathon Diercks, Michael Obermeier, Marc Tompkins, Terese L Chmielewski
Format: Article
Language:English
Published: North American Sports Medicine Institute 2024-10-01
Series:International Journal of Sports Physical Therapy
Online Access:https://doi.org/10.26603/001c.123512
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1825139395340009472
author Chad Kofoed
Allison Palmsten
Jonathon Diercks
Michael Obermeier
Marc Tompkins
Terese L Chmielewski
author_facet Chad Kofoed
Allison Palmsten
Jonathon Diercks
Michael Obermeier
Marc Tompkins
Terese L Chmielewski
author_sort Chad Kofoed
collection DOAJ
description # Background The seated wall angel (SWA) is an intervention to improve upper quarter mobility but has not been described as a clinical test with scoring. # Hypothesis/ Purpose To explore the clinical utility of the SWA as a test with scoring. The authors hypothesized that SWA test scores would be lower on the injured than uninjured side, improve over time, and show stronger association with patient-reported shoulder function than shoulder mobility tests. # Study Design Prospective cohort. # Methods Patients diagnosed with anterior shoulder instability and referred to physical therapy participated. Testing occurred after physical therapy examination (initial) and six weeks later (follow-up). Rehabilitation was not controlled. Testing included clinical tests (SWA, passive shoulder external rotation range of motion, total arc of motion) and patient-reported outcomes including the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, (ASES) and the Western Ontario Shoulder Instability Index (WOSI). The SWA test was scored 0 to 3 points bilaterally based on number of body contacts with the wall (i.e., elbows and fingertips, posterior fingers, posterior forearm). Passive range of motion was measured with a standard goniometer. SWA scores were compared between sides at initial testing and compared between testing timepoints on the injured side. Associations among injured side clinical test values and patient-reported outcome scores were examined. # Results Mean (SD) SWA score on the injured side was significantly lower than the uninjured side at initial testing \[1.6 (1.0) vs 2.2 (1.1), p = 0.045] and significantly increased at follow-up testing \[2.4 (1.0), p = 0.041]. Only SWA test score was significantly correlated with ASES (r=0.597) and WOSI (r=-0.648) scores at initial testing, and SWA test score was significantly correlated with WOSI score at follow-up testing (r=-0.611). # Conclusions The clinical utility of the SWA test is supported by distinguishing the injured and uninjured sides and having stronger associations with patient-reported shoulder function than shoulder mobility tests.
format Article
id doaj-art-9c7b8a8c5a6a402c8805bd1bdfec772c
institution Kabale University
issn 2159-2896
language English
publishDate 2024-10-01
publisher North American Sports Medicine Institute
record_format Article
series International Journal of Sports Physical Therapy
spelling doaj-art-9c7b8a8c5a6a402c8805bd1bdfec772c2025-02-11T20:29:59ZengNorth American Sports Medicine InstituteInternational Journal of Sports Physical Therapy2159-28962024-10-011910The Clinical Utility of the Seated Wall Angel as a Test with ScoringChad KofoedAllison PalmstenJonathon DiercksMichael ObermeierMarc TompkinsTerese L Chmielewski# Background The seated wall angel (SWA) is an intervention to improve upper quarter mobility but has not been described as a clinical test with scoring. # Hypothesis/ Purpose To explore the clinical utility of the SWA as a test with scoring. The authors hypothesized that SWA test scores would be lower on the injured than uninjured side, improve over time, and show stronger association with patient-reported shoulder function than shoulder mobility tests. # Study Design Prospective cohort. # Methods Patients diagnosed with anterior shoulder instability and referred to physical therapy participated. Testing occurred after physical therapy examination (initial) and six weeks later (follow-up). Rehabilitation was not controlled. Testing included clinical tests (SWA, passive shoulder external rotation range of motion, total arc of motion) and patient-reported outcomes including the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, (ASES) and the Western Ontario Shoulder Instability Index (WOSI). The SWA test was scored 0 to 3 points bilaterally based on number of body contacts with the wall (i.e., elbows and fingertips, posterior fingers, posterior forearm). Passive range of motion was measured with a standard goniometer. SWA scores were compared between sides at initial testing and compared between testing timepoints on the injured side. Associations among injured side clinical test values and patient-reported outcome scores were examined. # Results Mean (SD) SWA score on the injured side was significantly lower than the uninjured side at initial testing \[1.6 (1.0) vs 2.2 (1.1), p = 0.045] and significantly increased at follow-up testing \[2.4 (1.0), p = 0.041]. Only SWA test score was significantly correlated with ASES (r=0.597) and WOSI (r=-0.648) scores at initial testing, and SWA test score was significantly correlated with WOSI score at follow-up testing (r=-0.611). # Conclusions The clinical utility of the SWA test is supported by distinguishing the injured and uninjured sides and having stronger associations with patient-reported shoulder function than shoulder mobility tests.https://doi.org/10.26603/001c.123512
spellingShingle Chad Kofoed
Allison Palmsten
Jonathon Diercks
Michael Obermeier
Marc Tompkins
Terese L Chmielewski
The Clinical Utility of the Seated Wall Angel as a Test with Scoring
International Journal of Sports Physical Therapy
title The Clinical Utility of the Seated Wall Angel as a Test with Scoring
title_full The Clinical Utility of the Seated Wall Angel as a Test with Scoring
title_fullStr The Clinical Utility of the Seated Wall Angel as a Test with Scoring
title_full_unstemmed The Clinical Utility of the Seated Wall Angel as a Test with Scoring
title_short The Clinical Utility of the Seated Wall Angel as a Test with Scoring
title_sort clinical utility of the seated wall angel as a test with scoring
url https://doi.org/10.26603/001c.123512
work_keys_str_mv AT chadkofoed theclinicalutilityoftheseatedwallangelasatestwithscoring
AT allisonpalmsten theclinicalutilityoftheseatedwallangelasatestwithscoring
AT jonathondiercks theclinicalutilityoftheseatedwallangelasatestwithscoring
AT michaelobermeier theclinicalutilityoftheseatedwallangelasatestwithscoring
AT marctompkins theclinicalutilityoftheseatedwallangelasatestwithscoring
AT tereselchmielewski theclinicalutilityoftheseatedwallangelasatestwithscoring
AT chadkofoed clinicalutilityoftheseatedwallangelasatestwithscoring
AT allisonpalmsten clinicalutilityoftheseatedwallangelasatestwithscoring
AT jonathondiercks clinicalutilityoftheseatedwallangelasatestwithscoring
AT michaelobermeier clinicalutilityoftheseatedwallangelasatestwithscoring
AT marctompkins clinicalutilityoftheseatedwallangelasatestwithscoring
AT tereselchmielewski clinicalutilityoftheseatedwallangelasatestwithscoring