Sutureless Intrascleral Haptic-Hook Lens Implantation Using 25-Gauge Trocars
Purpose. To report a new technique for sutureless intrascleral fixation of three-piece foldable intraocular lenses (IOLs) using 25-gauge trocars. Methods. We performed this technique on patients with insufficient posterior capsule support. Seventeen eyes from 15 patients with aphakia, dislocated IOL...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2018-01-01
|
Series: | Journal of Ophthalmology |
Online Access: | http://dx.doi.org/10.1155/2018/9250425 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832553348750901248 |
---|---|
author | Zhi-Xiang Hu HaiShuang Lin Lingying Ye Zhong Lin Tianyu Chen Ke Lin Rong-Han Wu |
author_facet | Zhi-Xiang Hu HaiShuang Lin Lingying Ye Zhong Lin Tianyu Chen Ke Lin Rong-Han Wu |
author_sort | Zhi-Xiang Hu |
collection | DOAJ |
description | Purpose. To report a new technique for sutureless intrascleral fixation of three-piece foldable intraocular lenses (IOLs) using 25-gauge trocars. Methods. We performed this technique on patients with insufficient posterior capsule support. Seventeen eyes from 15 patients with aphakia, dislocated IOL, or subluxated crystalline lens undergoing posterior chamber sutureless implantation of an IOL were studied. The haptics of the IOL were externalized using two 25-gauge forceps. The haptics were bended back (hook-like) into the vitreous cavity through a scleral incision made by using a 25-gauge trocar. And, IOL tilt was determined by using a slit lamp and UBM, and complications were recorded. Results. The IOLs were fixed with exact centration and axial stability. No wound leakage was reported even without the use of sutures. The mean best-corrected visual acuity (BCVA) was 0.82 logarithm of the minimum angle of resolution (logMAR) units preoperatively, and the mean BCVA was 0.44 logMAR units at the 6-month follow-up visit. No postoperative retinal detachment, endophthalmitis, IOL tilt or dislocation, or vitreous hemorrhage was noted. Conclusion. Sutureless intrascleral haptic-hook posterior chamber IOL implantation using 25-gauge trocars provides good IOL fixation with reliable wound closure without the use of sutures. This trial is registered with ChiCTR1800017436. |
format | Article |
id | doaj-art-9bd5d76a34934d469b561ba61bd8f0dc |
institution | Kabale University |
issn | 2090-004X 2090-0058 |
language | English |
publishDate | 2018-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Ophthalmology |
spelling | doaj-art-9bd5d76a34934d469b561ba61bd8f0dc2025-02-03T05:54:11ZengWileyJournal of Ophthalmology2090-004X2090-00582018-01-01201810.1155/2018/92504259250425Sutureless Intrascleral Haptic-Hook Lens Implantation Using 25-Gauge TrocarsZhi-Xiang Hu0HaiShuang Lin1Lingying Ye2Zhong Lin3Tianyu Chen4Ke Lin5Rong-Han Wu6Eye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, 270 Xueyuan Road, Wenzhou, Zhejiang Province 325027, ChinaEye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, 270 Xueyuan Road, Wenzhou, Zhejiang Province 325027, ChinaEye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, 270 Xueyuan Road, Wenzhou, Zhejiang Province 325027, ChinaEye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, 270 Xueyuan Road, Wenzhou, Zhejiang Province 325027, ChinaEye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, 270 Xueyuan Road, Wenzhou, Zhejiang Province 325027, ChinaEye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, 270 Xueyuan Road, Wenzhou, Zhejiang Province 325027, ChinaEye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, 270 Xueyuan Road, Wenzhou, Zhejiang Province 325027, ChinaPurpose. To report a new technique for sutureless intrascleral fixation of three-piece foldable intraocular lenses (IOLs) using 25-gauge trocars. Methods. We performed this technique on patients with insufficient posterior capsule support. Seventeen eyes from 15 patients with aphakia, dislocated IOL, or subluxated crystalline lens undergoing posterior chamber sutureless implantation of an IOL were studied. The haptics of the IOL were externalized using two 25-gauge forceps. The haptics were bended back (hook-like) into the vitreous cavity through a scleral incision made by using a 25-gauge trocar. And, IOL tilt was determined by using a slit lamp and UBM, and complications were recorded. Results. The IOLs were fixed with exact centration and axial stability. No wound leakage was reported even without the use of sutures. The mean best-corrected visual acuity (BCVA) was 0.82 logarithm of the minimum angle of resolution (logMAR) units preoperatively, and the mean BCVA was 0.44 logMAR units at the 6-month follow-up visit. No postoperative retinal detachment, endophthalmitis, IOL tilt or dislocation, or vitreous hemorrhage was noted. Conclusion. Sutureless intrascleral haptic-hook posterior chamber IOL implantation using 25-gauge trocars provides good IOL fixation with reliable wound closure without the use of sutures. This trial is registered with ChiCTR1800017436.http://dx.doi.org/10.1155/2018/9250425 |
spellingShingle | Zhi-Xiang Hu HaiShuang Lin Lingying Ye Zhong Lin Tianyu Chen Ke Lin Rong-Han Wu Sutureless Intrascleral Haptic-Hook Lens Implantation Using 25-Gauge Trocars Journal of Ophthalmology |
title | Sutureless Intrascleral Haptic-Hook Lens Implantation Using 25-Gauge Trocars |
title_full | Sutureless Intrascleral Haptic-Hook Lens Implantation Using 25-Gauge Trocars |
title_fullStr | Sutureless Intrascleral Haptic-Hook Lens Implantation Using 25-Gauge Trocars |
title_full_unstemmed | Sutureless Intrascleral Haptic-Hook Lens Implantation Using 25-Gauge Trocars |
title_short | Sutureless Intrascleral Haptic-Hook Lens Implantation Using 25-Gauge Trocars |
title_sort | sutureless intrascleral haptic hook lens implantation using 25 gauge trocars |
url | http://dx.doi.org/10.1155/2018/9250425 |
work_keys_str_mv | AT zhixianghu suturelessintrascleralhaptichooklensimplantationusing25gaugetrocars AT haishuanglin suturelessintrascleralhaptichooklensimplantationusing25gaugetrocars AT lingyingye suturelessintrascleralhaptichooklensimplantationusing25gaugetrocars AT zhonglin suturelessintrascleralhaptichooklensimplantationusing25gaugetrocars AT tianyuchen suturelessintrascleralhaptichooklensimplantationusing25gaugetrocars AT kelin suturelessintrascleralhaptichooklensimplantationusing25gaugetrocars AT ronghanwu suturelessintrascleralhaptichooklensimplantationusing25gaugetrocars |