THREE-STAGE SYNCHRONOUS OVERMODULATION CONTROL OF FIVE-PHASE INVERTERS

Novel three-stage algorithm of synchronous PWM control of five-phase inverter in the zone of overmodulation has been proposed and investigated. It provides smooth transition from linear modulation range to the ten-step operation mode of five-phase system at the maximum fundamental frequency, with fu...

Full description

Saved in:
Bibliographic Details
Main Authors: Oleschuk V., Griva R., Prudeak R., Sizov A.
Format: Article
Language:English
Published: Academy of Sciences of Moldova 2010-04-01
Series:Problems of the Regional Energetics
Subjects:
Online Access:http://journal.ie.asm.md/assets/files/m71_2_130.doc
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849250862048739328
author Oleschuk V.
Griva R.
Prudeak R.
Sizov A.
author_facet Oleschuk V.
Griva R.
Prudeak R.
Sizov A.
author_sort Oleschuk V.
collection DOAJ
description Novel three-stage algorithm of synchronous PWM control of five-phase inverter in the zone of overmodulation has been proposed and investigated. It provides smooth transition from linear modulation range to the ten-step operation mode of five-phase system at the maximum fundamental frequency, with full DC-bus voltage utilization. Simulations give the behavior of five-phase system during synchronous PWM control in the zone of overmodulation.
format Article
id doaj-art-9bb34ebdde15446dabcbe90e4bcd1a56
institution Kabale University
issn 1857-0070
language English
publishDate 2010-04-01
publisher Academy of Sciences of Moldova
record_format Article
series Problems of the Regional Energetics
spelling doaj-art-9bb34ebdde15446dabcbe90e4bcd1a562025-08-20T03:57:08ZengAcademy of Sciences of MoldovaProblems of the Regional Energetics1857-00702010-04-012010-11(12)2840THREE-STAGE SYNCHRONOUS OVERMODULATION CONTROL OF FIVE-PHASE INVERTERSOleschuk V. 0Griva R.1Prudeak R.2Sizov A.3Institute of Power Engineering of the ASMUniversity of PadovaInstitute of Power Engineering of the ASMInstitute of Power Engineering of the ASMNovel three-stage algorithm of synchronous PWM control of five-phase inverter in the zone of overmodulation has been proposed and investigated. It provides smooth transition from linear modulation range to the ten-step operation mode of five-phase system at the maximum fundamental frequency, with full DC-bus voltage utilization. Simulations give the behavior of five-phase system during synchronous PWM control in the zone of overmodulation.http://journal.ie.asm.md/assets/files/m71_2_130.docfive-phase voltage source inverter
spellingShingle Oleschuk V.
Griva R.
Prudeak R.
Sizov A.
THREE-STAGE SYNCHRONOUS OVERMODULATION CONTROL OF FIVE-PHASE INVERTERS
Problems of the Regional Energetics
five-phase voltage source inverter
title THREE-STAGE SYNCHRONOUS OVERMODULATION CONTROL OF FIVE-PHASE INVERTERS
title_full THREE-STAGE SYNCHRONOUS OVERMODULATION CONTROL OF FIVE-PHASE INVERTERS
title_fullStr THREE-STAGE SYNCHRONOUS OVERMODULATION CONTROL OF FIVE-PHASE INVERTERS
title_full_unstemmed THREE-STAGE SYNCHRONOUS OVERMODULATION CONTROL OF FIVE-PHASE INVERTERS
title_short THREE-STAGE SYNCHRONOUS OVERMODULATION CONTROL OF FIVE-PHASE INVERTERS
title_sort three stage synchronous overmodulation control of five phase inverters
topic five-phase voltage source inverter
url http://journal.ie.asm.md/assets/files/m71_2_130.doc
work_keys_str_mv AT oleschukv threestagesynchronousovermodulationcontroloffivephaseinverters
AT grivar threestagesynchronousovermodulationcontroloffivephaseinverters
AT prudeakr threestagesynchronousovermodulationcontroloffivephaseinverters
AT sizova threestagesynchronousovermodulationcontroloffivephaseinverters