Smartwatches in the assessment of heart failure patients in epidemiology and pathophysiology studies: A scoping review

Abstract A limited number of studies with smartwatches (SWs) investigated their potential in the field of heart failure (HF). The aim of this scoping review is to understand the extent of current literature on SWs in the HF population and the device's potential to improve disease management. Th...

Full description

Saved in:
Bibliographic Details
Main Authors: Solenn Fabien, Sandra Waechter, Gbenga A. Kayode, Berno Müller, Marietta Roth, Friedrich Koehler
Format: Article
Language:English
Published: Wiley 2025-06-01
Series:ESC Heart Failure
Subjects:
Online Access:https://doi.org/10.1002/ehf2.15226
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850191973849235456
author Solenn Fabien
Sandra Waechter
Gbenga A. Kayode
Berno Müller
Marietta Roth
Friedrich Koehler
author_facet Solenn Fabien
Sandra Waechter
Gbenga A. Kayode
Berno Müller
Marietta Roth
Friedrich Koehler
author_sort Solenn Fabien
collection DOAJ
description Abstract A limited number of studies with smartwatches (SWs) investigated their potential in the field of heart failure (HF). The aim of this scoping review is to understand the extent of current literature on SWs in the HF population and the device's potential to improve disease management. The literature search was performed on PubMed and Embase in March 2024. Inclusion criteria included the use of commercialized SWs, HF diagnosis and peer‐reviewed publications. Articles were excluded if the SW was not the study intervention or was part of a broader intervention programme. Reviews, case reports and study protocols were excluded. Of 1200 identified articles, 13 were included in the scoping review, encompassing 1171 patients with HF, and findings were presented in a descriptive summary table. Validity of several SW‐collected physiological metrics was assessed against established technologies. Heart rate and step count measures were deemed moderately accurate in the HF population with Fitbit trackers (n = 5 patients, r = 0.54) and Garmin watches [n = 15 patients (mean age: 65.5 ± 12.6 years), concordance correlation coefficient (CCC) = 0.89 for Vivofit 1 and CCC = 0.92 for Vivofit 3], respectively, while calorimetry was the least reliable measurement [n = 19 patients (mean age: 65.1 ± 6.6 years), mean difference to indirect calorimeter: P = 0.01 for Fitbit Charge 2, P = 0.02 for Mio Slice]. Wrist‐worn activity trackers were positively received by patients with HF [91.3% of adherence in research setting (n = 70 patients, median age (IQR): 79 years (76–82)), and 64% in real‐world environment (n = 14 patients)] and their health‐care providers (six cardiologists out of six acknowledged the data's usefulness), although device ownership ranged from 10 to 50% among the HF population. Physical activity information collected from SWs was found to be valuable in assisting cardiologists with their New York Heart Association (NYHA) functional class assessment, which is known for its limited objectivity and reproducibility. Multiple studies found that SWs, especially Fitbit devices, successfully identified a pattern where the degree of exercise intolerance increased with higher NYHA classes. These findings suggested that activity trackers can objectively evaluate the severity of physical activity limitations. As the functional classification of patients influences treatment strategies, SWs could serve as a valuable tool to facilitate and optimize outpatient disease management. SWs could be used as a complement to standard monitoring in HF. With continuous technological advances, it will be valuable to follow the deployment of SWs and to investigate their contribution to increased patient safety and consequently to health care cost reductions.
format Article
id doaj-art-9b7f09def8314e7fa11ceb8bbe71a622
institution OA Journals
issn 2055-5822
language English
publishDate 2025-06-01
publisher Wiley
record_format Article
series ESC Heart Failure
spelling doaj-art-9b7f09def8314e7fa11ceb8bbe71a6222025-08-20T02:14:43ZengWileyESC Heart Failure2055-58222025-06-011231727173810.1002/ehf2.15226Smartwatches in the assessment of heart failure patients in epidemiology and pathophysiology studies: A scoping reviewSolenn Fabien0Sandra Waechter1Gbenga A. Kayode2Berno Müller3Marietta Roth4Friedrich Koehler5CSL Vifor Glattbrugg SwitzerlandCSL Vifor Glattbrugg SwitzerlandCSL Behring King of Prussia Pennsylvania United StatesCSL Vifor Munich GermanyDepartment of Pharmaceutical Sciences University of Basel Basel SwitzerlandDepartment of Cardiology, Angiology and Intensive Care Medicine, Centre for Cardiovascular Telemedicine Deutsches Herzzentrum der Charité (DHZC) Berlin GermanyAbstract A limited number of studies with smartwatches (SWs) investigated their potential in the field of heart failure (HF). The aim of this scoping review is to understand the extent of current literature on SWs in the HF population and the device's potential to improve disease management. The literature search was performed on PubMed and Embase in March 2024. Inclusion criteria included the use of commercialized SWs, HF diagnosis and peer‐reviewed publications. Articles were excluded if the SW was not the study intervention or was part of a broader intervention programme. Reviews, case reports and study protocols were excluded. Of 1200 identified articles, 13 were included in the scoping review, encompassing 1171 patients with HF, and findings were presented in a descriptive summary table. Validity of several SW‐collected physiological metrics was assessed against established technologies. Heart rate and step count measures were deemed moderately accurate in the HF population with Fitbit trackers (n = 5 patients, r = 0.54) and Garmin watches [n = 15 patients (mean age: 65.5 ± 12.6 years), concordance correlation coefficient (CCC) = 0.89 for Vivofit 1 and CCC = 0.92 for Vivofit 3], respectively, while calorimetry was the least reliable measurement [n = 19 patients (mean age: 65.1 ± 6.6 years), mean difference to indirect calorimeter: P = 0.01 for Fitbit Charge 2, P = 0.02 for Mio Slice]. Wrist‐worn activity trackers were positively received by patients with HF [91.3% of adherence in research setting (n = 70 patients, median age (IQR): 79 years (76–82)), and 64% in real‐world environment (n = 14 patients)] and their health‐care providers (six cardiologists out of six acknowledged the data's usefulness), although device ownership ranged from 10 to 50% among the HF population. Physical activity information collected from SWs was found to be valuable in assisting cardiologists with their New York Heart Association (NYHA) functional class assessment, which is known for its limited objectivity and reproducibility. Multiple studies found that SWs, especially Fitbit devices, successfully identified a pattern where the degree of exercise intolerance increased with higher NYHA classes. These findings suggested that activity trackers can objectively evaluate the severity of physical activity limitations. As the functional classification of patients influences treatment strategies, SWs could serve as a valuable tool to facilitate and optimize outpatient disease management. SWs could be used as a complement to standard monitoring in HF. With continuous technological advances, it will be valuable to follow the deployment of SWs and to investigate their contribution to increased patient safety and consequently to health care cost reductions.https://doi.org/10.1002/ehf2.15226Disease managementHeart failureMobile healthSmartwatchesWearable devices
spellingShingle Solenn Fabien
Sandra Waechter
Gbenga A. Kayode
Berno Müller
Marietta Roth
Friedrich Koehler
Smartwatches in the assessment of heart failure patients in epidemiology and pathophysiology studies: A scoping review
ESC Heart Failure
Disease management
Heart failure
Mobile health
Smartwatches
Wearable devices
title Smartwatches in the assessment of heart failure patients in epidemiology and pathophysiology studies: A scoping review
title_full Smartwatches in the assessment of heart failure patients in epidemiology and pathophysiology studies: A scoping review
title_fullStr Smartwatches in the assessment of heart failure patients in epidemiology and pathophysiology studies: A scoping review
title_full_unstemmed Smartwatches in the assessment of heart failure patients in epidemiology and pathophysiology studies: A scoping review
title_short Smartwatches in the assessment of heart failure patients in epidemiology and pathophysiology studies: A scoping review
title_sort smartwatches in the assessment of heart failure patients in epidemiology and pathophysiology studies a scoping review
topic Disease management
Heart failure
Mobile health
Smartwatches
Wearable devices
url https://doi.org/10.1002/ehf2.15226
work_keys_str_mv AT solennfabien smartwatchesintheassessmentofheartfailurepatientsinepidemiologyandpathophysiologystudiesascopingreview
AT sandrawaechter smartwatchesintheassessmentofheartfailurepatientsinepidemiologyandpathophysiologystudiesascopingreview
AT gbengaakayode smartwatchesintheassessmentofheartfailurepatientsinepidemiologyandpathophysiologystudiesascopingreview
AT bernomuller smartwatchesintheassessmentofheartfailurepatientsinepidemiologyandpathophysiologystudiesascopingreview
AT mariettaroth smartwatchesintheassessmentofheartfailurepatientsinepidemiologyandpathophysiologystudiesascopingreview
AT friedrichkoehler smartwatchesintheassessmentofheartfailurepatientsinepidemiologyandpathophysiologystudiesascopingreview