Finite Difference Computation of Au-Cu/Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis Artery

The present study addresses the fluid transport behaviour of the flow of gold (Au)-copper (Cu)/biomagnetic blood hybrid nanofluid in an inclined irregular stenosis artery as a consequence of varying viscosity and Lorentz force. The nonlinear flow equations are transformed into dimensionless form by...

Full description

Saved in:
Bibliographic Details
Main Authors: H. Thameem Basha, Karthikeyan Rajagopal, N. Ameer Ahammad, S. Sathish, Sreedhara Rao Gunakala
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Complexity
Online Access:http://dx.doi.org/10.1155/2022/2078372
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832548339883704320
author H. Thameem Basha
Karthikeyan Rajagopal
N. Ameer Ahammad
S. Sathish
Sreedhara Rao Gunakala
author_facet H. Thameem Basha
Karthikeyan Rajagopal
N. Ameer Ahammad
S. Sathish
Sreedhara Rao Gunakala
author_sort H. Thameem Basha
collection DOAJ
description The present study addresses the fluid transport behaviour of the flow of gold (Au)-copper (Cu)/biomagnetic blood hybrid nanofluid in an inclined irregular stenosis artery as a consequence of varying viscosity and Lorentz force. The nonlinear flow equations are transformed into dimensionless form by using nonsimilar variables. The finite-difference technique (FTCS) is involved in computing the nonlinear transport dimensionless equations. The significant parameters like angle parameter, the Hartmann number, changing viscosity, constant heat source, the Reynolds number, and nanoparticle volume fraction on the flow field are exhibited through figures. Present results disclose that the Lorentz force strongly lessens the hybrid nanofluid velocity. Elevating the Grashof number values enhances the rate of blood flow. Growing values of the angle parameter cause to reduce the resistance impedance on the wall. Hybrid nanoparticles have a superior wall shear stress than copper nanoparticles. The heat transfer rate is amplifying at the axial direction with the growing values of nanoparticles concentration. The applied Lorentz force significantly reduces the hybrid and unitary nanofluid flow rate in the axial direction. The hybrid nanoparticles expose a supreme rate of heat transfer than the copper nanoparticles in a blood base fluid. Compared to hybrid and copper nanofluid, the blood base fluid has a lower temperature.
format Article
id doaj-art-9aa0ae8ea4714ad48cd694645701e39f
institution Kabale University
issn 1099-0526
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Complexity
spelling doaj-art-9aa0ae8ea4714ad48cd694645701e39f2025-02-03T06:14:20ZengWileyComplexity1099-05262022-01-01202210.1155/2022/2078372Finite Difference Computation of Au-Cu/Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis ArteryH. Thameem Basha0Karthikeyan Rajagopal1N. Ameer Ahammad2S. Sathish3Sreedhara Rao Gunakala4Centre for Nonlinear SystemsCentre for Nonlinear SystemsDepartment of MathematicsSchool of Mathematics and StatisticsDepartment of Mathematics and StatisticsThe present study addresses the fluid transport behaviour of the flow of gold (Au)-copper (Cu)/biomagnetic blood hybrid nanofluid in an inclined irregular stenosis artery as a consequence of varying viscosity and Lorentz force. The nonlinear flow equations are transformed into dimensionless form by using nonsimilar variables. The finite-difference technique (FTCS) is involved in computing the nonlinear transport dimensionless equations. The significant parameters like angle parameter, the Hartmann number, changing viscosity, constant heat source, the Reynolds number, and nanoparticle volume fraction on the flow field are exhibited through figures. Present results disclose that the Lorentz force strongly lessens the hybrid nanofluid velocity. Elevating the Grashof number values enhances the rate of blood flow. Growing values of the angle parameter cause to reduce the resistance impedance on the wall. Hybrid nanoparticles have a superior wall shear stress than copper nanoparticles. The heat transfer rate is amplifying at the axial direction with the growing values of nanoparticles concentration. The applied Lorentz force significantly reduces the hybrid and unitary nanofluid flow rate in the axial direction. The hybrid nanoparticles expose a supreme rate of heat transfer than the copper nanoparticles in a blood base fluid. Compared to hybrid and copper nanofluid, the blood base fluid has a lower temperature.http://dx.doi.org/10.1155/2022/2078372
spellingShingle H. Thameem Basha
Karthikeyan Rajagopal
N. Ameer Ahammad
S. Sathish
Sreedhara Rao Gunakala
Finite Difference Computation of Au-Cu/Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis Artery
Complexity
title Finite Difference Computation of Au-Cu/Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis Artery
title_full Finite Difference Computation of Au-Cu/Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis Artery
title_fullStr Finite Difference Computation of Au-Cu/Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis Artery
title_full_unstemmed Finite Difference Computation of Au-Cu/Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis Artery
title_short Finite Difference Computation of Au-Cu/Magneto-Bio-Hybrid Nanofluid Flow in an Inclined Uneven Stenosis Artery
title_sort finite difference computation of au cu magneto bio hybrid nanofluid flow in an inclined uneven stenosis artery
url http://dx.doi.org/10.1155/2022/2078372
work_keys_str_mv AT hthameembasha finitedifferencecomputationofaucumagnetobiohybridnanofluidflowinaninclinedunevenstenosisartery
AT karthikeyanrajagopal finitedifferencecomputationofaucumagnetobiohybridnanofluidflowinaninclinedunevenstenosisartery
AT nameerahammad finitedifferencecomputationofaucumagnetobiohybridnanofluidflowinaninclinedunevenstenosisartery
AT ssathish finitedifferencecomputationofaucumagnetobiohybridnanofluidflowinaninclinedunevenstenosisartery
AT sreedhararaogunakala finitedifferencecomputationofaucumagnetobiohybridnanofluidflowinaninclinedunevenstenosisartery