Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller

As key equipment in nuclear power plant, the reactor power control system is adopted to strictly control and regulate the reactor power of a PWR (pressurized water reactor) in a nuclear power plant. A well-optimized predictive control algorithm based on SDMC (stepped dynamic matrix controller) is de...

Full description

Saved in:
Bibliographic Details
Main Authors: Xu Zhang, Zhiguang Deng, Jun Li, Youwei Yang, Quan Ma, Mingming Liu
Format: Article
Language:English
Published: Wiley 2019-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2019/4973120
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849404213208023040
author Xu Zhang
Zhiguang Deng
Jun Li
Youwei Yang
Quan Ma
Mingming Liu
author_facet Xu Zhang
Zhiguang Deng
Jun Li
Youwei Yang
Quan Ma
Mingming Liu
author_sort Xu Zhang
collection DOAJ
description As key equipment in nuclear power plant, the reactor power control system is adopted to strictly control and regulate the reactor power of a PWR (pressurized water reactor) in a nuclear power plant. A well-optimized predictive control algorithm based on SDMC (stepped dynamic matrix controller) is developed and introduced in this paper and applied to the power regulation of a reactor power model. In addition, the test and verification of this application is conducted by two different methods and devices: the virtual verification platform and the physical DCS (digital control system). The result of the verification suggests that the application of SDMC gains a better performance in the maximum dynamic deviation, adjustment time, overshoot, and so on.
format Article
id doaj-art-995faf4a40754b05a6169bc876ea2a68
institution Kabale University
issn 1687-6075
1687-6083
language English
publishDate 2019-01-01
publisher Wiley
record_format Article
series Science and Technology of Nuclear Installations
spelling doaj-art-995faf4a40754b05a6169bc876ea2a682025-08-20T03:37:03ZengWileyScience and Technology of Nuclear Installations1687-60751687-60832019-01-01201910.1155/2019/49731204973120Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix ControllerXu Zhang0Zhiguang Deng1Jun Li2Youwei Yang3Quan Ma4Mingming Liu5Nuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaAs key equipment in nuclear power plant, the reactor power control system is adopted to strictly control and regulate the reactor power of a PWR (pressurized water reactor) in a nuclear power plant. A well-optimized predictive control algorithm based on SDMC (stepped dynamic matrix controller) is developed and introduced in this paper and applied to the power regulation of a reactor power model. In addition, the test and verification of this application is conducted by two different methods and devices: the virtual verification platform and the physical DCS (digital control system). The result of the verification suggests that the application of SDMC gains a better performance in the maximum dynamic deviation, adjustment time, overshoot, and so on.http://dx.doi.org/10.1155/2019/4973120
spellingShingle Xu Zhang
Zhiguang Deng
Jun Li
Youwei Yang
Quan Ma
Mingming Liu
Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller
Science and Technology of Nuclear Installations
title Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller
title_full Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller
title_fullStr Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller
title_full_unstemmed Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller
title_short Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller
title_sort design and verification of reactor power control based on stepped dynamic matrix controller
url http://dx.doi.org/10.1155/2019/4973120
work_keys_str_mv AT xuzhang designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller
AT zhiguangdeng designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller
AT junli designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller
AT youweiyang designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller
AT quanma designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller
AT mingmingliu designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller