Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller
As key equipment in nuclear power plant, the reactor power control system is adopted to strictly control and regulate the reactor power of a PWR (pressurized water reactor) in a nuclear power plant. A well-optimized predictive control algorithm based on SDMC (stepped dynamic matrix controller) is de...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2019-01-01
|
| Series: | Science and Technology of Nuclear Installations |
| Online Access: | http://dx.doi.org/10.1155/2019/4973120 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849404213208023040 |
|---|---|
| author | Xu Zhang Zhiguang Deng Jun Li Youwei Yang Quan Ma Mingming Liu |
| author_facet | Xu Zhang Zhiguang Deng Jun Li Youwei Yang Quan Ma Mingming Liu |
| author_sort | Xu Zhang |
| collection | DOAJ |
| description | As key equipment in nuclear power plant, the reactor power control system is adopted to strictly control and regulate the reactor power of a PWR (pressurized water reactor) in a nuclear power plant. A well-optimized predictive control algorithm based on SDMC (stepped dynamic matrix controller) is developed and introduced in this paper and applied to the power regulation of a reactor power model. In addition, the test and verification of this application is conducted by two different methods and devices: the virtual verification platform and the physical DCS (digital control system). The result of the verification suggests that the application of SDMC gains a better performance in the maximum dynamic deviation, adjustment time, overshoot, and so on. |
| format | Article |
| id | doaj-art-995faf4a40754b05a6169bc876ea2a68 |
| institution | Kabale University |
| issn | 1687-6075 1687-6083 |
| language | English |
| publishDate | 2019-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | Science and Technology of Nuclear Installations |
| spelling | doaj-art-995faf4a40754b05a6169bc876ea2a682025-08-20T03:37:03ZengWileyScience and Technology of Nuclear Installations1687-60751687-60832019-01-01201910.1155/2019/49731204973120Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix ControllerXu Zhang0Zhiguang Deng1Jun Li2Youwei Yang3Quan Ma4Mingming Liu5Nuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaNuclear Power Institute of China, Science and Technology on Reactor System Design Technology Laboratory, Chengdu 610213, ChinaAs key equipment in nuclear power plant, the reactor power control system is adopted to strictly control and regulate the reactor power of a PWR (pressurized water reactor) in a nuclear power plant. A well-optimized predictive control algorithm based on SDMC (stepped dynamic matrix controller) is developed and introduced in this paper and applied to the power regulation of a reactor power model. In addition, the test and verification of this application is conducted by two different methods and devices: the virtual verification platform and the physical DCS (digital control system). The result of the verification suggests that the application of SDMC gains a better performance in the maximum dynamic deviation, adjustment time, overshoot, and so on.http://dx.doi.org/10.1155/2019/4973120 |
| spellingShingle | Xu Zhang Zhiguang Deng Jun Li Youwei Yang Quan Ma Mingming Liu Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller Science and Technology of Nuclear Installations |
| title | Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller |
| title_full | Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller |
| title_fullStr | Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller |
| title_full_unstemmed | Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller |
| title_short | Design and Verification of Reactor Power Control Based on Stepped Dynamic Matrix Controller |
| title_sort | design and verification of reactor power control based on stepped dynamic matrix controller |
| url | http://dx.doi.org/10.1155/2019/4973120 |
| work_keys_str_mv | AT xuzhang designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller AT zhiguangdeng designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller AT junli designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller AT youweiyang designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller AT quanma designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller AT mingmingliu designandverificationofreactorpowercontrolbasedonsteppeddynamicmatrixcontroller |