Reliability and validity of the six-minute step test in assessing the functional capacity of hemodialysis patients

Purpose Hemodialysis patients often experience functional limitations that are challenging to assess due to equipment and space constraints. The 6-min step test (6MST) requires little space and a small standardized ergometer, making it more accessible and feasible in various healthcare settings, whe...

Full description

Saved in:
Bibliographic Details
Main Authors: Carla Cristina Lima, Maria Eduarda Godoy, Débora Kellen Ferreira Fratoni, Elaine Paulin
Format: Article
Language:English
Published: PeerJ Inc. 2025-07-01
Series:PeerJ
Subjects:
Online Access:https://peerj.com/articles/19157.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849319939857448960
author Carla Cristina Lima
Maria Eduarda Godoy
Débora Kellen Ferreira Fratoni
Elaine Paulin
author_facet Carla Cristina Lima
Maria Eduarda Godoy
Débora Kellen Ferreira Fratoni
Elaine Paulin
author_sort Carla Cristina Lima
collection DOAJ
description Purpose Hemodialysis patients often experience functional limitations that are challenging to assess due to equipment and space constraints. The 6-min step test (6MST) requires little space and a small standardized ergometer, making it more accessible and feasible in various healthcare settings, when compared to the cardiopulmonary exercise test (CPET) and the 6-min walk test (6MWT). Thus, the aim of this study is to evaluate the test-retest reliability and concurrent validity of the 6MST for assessing the functional capacity of hemodialysis patients. Methods Assessments conducted included anthropometry, spirometry, 6MWT, and 6MST. These two tests were randomized and performed on alternate days. Two 6MSTs and two 6MWTs were conducted with a minimum interval of 30 min between them. Results The study involved 32 participants, 67% men (n = 22) and 33% women (n = 10), with an average age of 57 ± 13 years and body mass index (BMI) of 28.6 ± 5.2 kg/m2. The 6MST demonstrated high test-retest reliability (ICC = 0.94 (95% CI [0.85–0.97]; p < 0.001)) and a strong correlation between the number of steps performed in the 6MST and the distance covered in the 6MWT (r = 0.87; p < 0.001). A learning effect was observed, with a 7% improvement on retesting. Conclusion The 6MST provides a feasible, reliable assessment option for hemodialysis patients and could be easily implemented in clinics lacking space and specialized equipment. Limitation of the present study are being a single-center investigation with a small sample size, thus limiting generalizability, and the variability of patient conditions, which may have influenced the results. Future research should explore the 6’ long-term stability, responsiveness, and impact on patient-centered outcomes, as well as its applicability across different hemodialysis populations and clinical settings, to improve its clinical usefulness.
format Article
id doaj-art-995e112b34414cc09664d02a80d4f44c
institution Kabale University
issn 2167-8359
language English
publishDate 2025-07-01
publisher PeerJ Inc.
record_format Article
series PeerJ
spelling doaj-art-995e112b34414cc09664d02a80d4f44c2025-08-20T03:50:16ZengPeerJ Inc.PeerJ2167-83592025-07-0113e1915710.7717/peerj.19157Reliability and validity of the six-minute step test in assessing the functional capacity of hemodialysis patientsCarla Cristina LimaMaria Eduarda GodoyDébora Kellen Ferreira FratoniElaine PaulinPurpose Hemodialysis patients often experience functional limitations that are challenging to assess due to equipment and space constraints. The 6-min step test (6MST) requires little space and a small standardized ergometer, making it more accessible and feasible in various healthcare settings, when compared to the cardiopulmonary exercise test (CPET) and the 6-min walk test (6MWT). Thus, the aim of this study is to evaluate the test-retest reliability and concurrent validity of the 6MST for assessing the functional capacity of hemodialysis patients. Methods Assessments conducted included anthropometry, spirometry, 6MWT, and 6MST. These two tests were randomized and performed on alternate days. Two 6MSTs and two 6MWTs were conducted with a minimum interval of 30 min between them. Results The study involved 32 participants, 67% men (n = 22) and 33% women (n = 10), with an average age of 57 ± 13 years and body mass index (BMI) of 28.6 ± 5.2 kg/m2. The 6MST demonstrated high test-retest reliability (ICC = 0.94 (95% CI [0.85–0.97]; p < 0.001)) and a strong correlation between the number of steps performed in the 6MST and the distance covered in the 6MWT (r = 0.87; p < 0.001). A learning effect was observed, with a 7% improvement on retesting. Conclusion The 6MST provides a feasible, reliable assessment option for hemodialysis patients and could be easily implemented in clinics lacking space and specialized equipment. Limitation of the present study are being a single-center investigation with a small sample size, thus limiting generalizability, and the variability of patient conditions, which may have influenced the results. Future research should explore the 6’ long-term stability, responsiveness, and impact on patient-centered outcomes, as well as its applicability across different hemodialysis populations and clinical settings, to improve its clinical usefulness.https://peerj.com/articles/19157.pdfHemodialysisFunctional capacityReliabilityValidityKidney disease
spellingShingle Carla Cristina Lima
Maria Eduarda Godoy
Débora Kellen Ferreira Fratoni
Elaine Paulin
Reliability and validity of the six-minute step test in assessing the functional capacity of hemodialysis patients
PeerJ
Hemodialysis
Functional capacity
Reliability
Validity
Kidney disease
title Reliability and validity of the six-minute step test in assessing the functional capacity of hemodialysis patients
title_full Reliability and validity of the six-minute step test in assessing the functional capacity of hemodialysis patients
title_fullStr Reliability and validity of the six-minute step test in assessing the functional capacity of hemodialysis patients
title_full_unstemmed Reliability and validity of the six-minute step test in assessing the functional capacity of hemodialysis patients
title_short Reliability and validity of the six-minute step test in assessing the functional capacity of hemodialysis patients
title_sort reliability and validity of the six minute step test in assessing the functional capacity of hemodialysis patients
topic Hemodialysis
Functional capacity
Reliability
Validity
Kidney disease
url https://peerj.com/articles/19157.pdf
work_keys_str_mv AT carlacristinalima reliabilityandvalidityofthesixminutesteptestinassessingthefunctionalcapacityofhemodialysispatients
AT mariaeduardagodoy reliabilityandvalidityofthesixminutesteptestinassessingthefunctionalcapacityofhemodialysispatients
AT deborakellenferreirafratoni reliabilityandvalidityofthesixminutesteptestinassessingthefunctionalcapacityofhemodialysispatients
AT elainepaulin reliabilityandvalidityofthesixminutesteptestinassessingthefunctionalcapacityofhemodialysispatients