Comparative Analysis of Irrigation Mist and CO<sub>2</sub> vs. Direct CO<sub>2</sub> Blower in On-Pump Coronary Artery Bypass Grafting Anastomosis: Efficacy, Efficiency, and Fibrillation upon De-Clamping and Micro-Embolic Gas Activity Incidence

<i>Background and Objectives:</i> In coronary artery bypass grafting (CABG) on pump, achieving optimal visualization is critical for surgical precision and safety. The use of blowers to clear the CABG anastomosis poses risks, including the formation of micro-embolic gas bubbles, which ca...

Full description

Saved in:
Bibliographic Details
Main Authors: Ignazio Condello, Giuseppe Speziale, Flavio Fiore, Giuseppe Nasso
Format: Article
Language:English
Published: MDPI AG 2024-12-01
Series:Medicina
Subjects:
Online Access:https://www.mdpi.com/1648-9144/60/12/2035
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850085759628869632
author Ignazio Condello
Giuseppe Speziale
Flavio Fiore
Giuseppe Nasso
author_facet Ignazio Condello
Giuseppe Speziale
Flavio Fiore
Giuseppe Nasso
author_sort Ignazio Condello
collection DOAJ
description <i>Background and Objectives:</i> In coronary artery bypass grafting (CABG) on pump, achieving optimal visualization is critical for surgical precision and safety. The use of blowers to clear the CABG anastomosis poses risks, including the formation of micro-embolic gas bubbles, which can be insidious and increase the risk of cerebral or myocardial complications. This retrospective study compares the effectiveness of the use of irrigation mist and CO<sub>2</sub> versus a direct CO<sub>2</sub> blower without irrigation in terms of visualization, postoperative fibrillation, and micro-embolic gas activity. <i>Materials and Methods:</i> The study involved 40 patients who underwent on-pump CABG, with 20 patients assigned to the irrigation mist and CO<sub>2</sub> group (ClearView™) and 20 to the direct CO<sub>2</sub> blower group. Primary outcomes included the quality of intraoperative visualization, the incidence of fibrillation at aortic de-clamping, and the presence of micro-embolic gas activity detected via transesophageal echocardiography (TEE) in the cardiac chambers. <i>Results:</i> Patients in the irrigation mist and CO<sub>2</sub> group experienced superior visualization and reduced tissue desiccation. Fibrillation at the time of aortic de-clamping occurred in two patients (10%) using the irrigation mist and CO<sub>2</sub>, compared to eight patients (40%) using the direct CO<sub>2</sub> blower. Additionally, TEE monitoring revealed lower levels of micro-embolic gas activity in the irrigation mist and CO<sub>2</sub> group, indicating a potential reduction in gas embolization risk. <i>Conclusions:</i> The irrigation mist and CO<sub>2</sub> system not only provides enhanced visualization during CABG but also significantly reduces the incidence of fibrillation during aortic de-clamping and micro-embolic gas activity. These findings suggest improved patient safety and outcomes, highlighting the irrigation mist and CO<sub>2</sub> system as a potentially safer alternative to direct CO<sub>2</sub> blowing in the context of myocardial revascularization.
format Article
id doaj-art-9948cbeef1c94a5f86bc24b2f131cdb1
institution DOAJ
issn 1010-660X
1648-9144
language English
publishDate 2024-12-01
publisher MDPI AG
record_format Article
series Medicina
spelling doaj-art-9948cbeef1c94a5f86bc24b2f131cdb12025-08-20T02:43:38ZengMDPI AGMedicina1010-660X1648-91442024-12-016012203510.3390/medicina60122035Comparative Analysis of Irrigation Mist and CO<sub>2</sub> vs. Direct CO<sub>2</sub> Blower in On-Pump Coronary Artery Bypass Grafting Anastomosis: Efficacy, Efficiency, and Fibrillation upon De-Clamping and Micro-Embolic Gas Activity IncidenceIgnazio Condello0Giuseppe Speziale1Flavio Fiore2Giuseppe Nasso3Department of Cardiac Surgery, Anthea Hospital GVM Care and Research, Via Camillo Rosalba 35/37, 70124 Bari, ItalyDepartment of Cardiac Surgery, Anthea Hospital GVM Care and Research, Via Camillo Rosalba 35/37, 70124 Bari, ItalyDepartment of Cardiac Surgery, Anthea Hospital GVM Care and Research, Via Camillo Rosalba 35/37, 70124 Bari, ItalyDepartment of Cardiac Surgery, Anthea Hospital GVM Care and Research, Via Camillo Rosalba 35/37, 70124 Bari, Italy<i>Background and Objectives:</i> In coronary artery bypass grafting (CABG) on pump, achieving optimal visualization is critical for surgical precision and safety. The use of blowers to clear the CABG anastomosis poses risks, including the formation of micro-embolic gas bubbles, which can be insidious and increase the risk of cerebral or myocardial complications. This retrospective study compares the effectiveness of the use of irrigation mist and CO<sub>2</sub> versus a direct CO<sub>2</sub> blower without irrigation in terms of visualization, postoperative fibrillation, and micro-embolic gas activity. <i>Materials and Methods:</i> The study involved 40 patients who underwent on-pump CABG, with 20 patients assigned to the irrigation mist and CO<sub>2</sub> group (ClearView™) and 20 to the direct CO<sub>2</sub> blower group. Primary outcomes included the quality of intraoperative visualization, the incidence of fibrillation at aortic de-clamping, and the presence of micro-embolic gas activity detected via transesophageal echocardiography (TEE) in the cardiac chambers. <i>Results:</i> Patients in the irrigation mist and CO<sub>2</sub> group experienced superior visualization and reduced tissue desiccation. Fibrillation at the time of aortic de-clamping occurred in two patients (10%) using the irrigation mist and CO<sub>2</sub>, compared to eight patients (40%) using the direct CO<sub>2</sub> blower. Additionally, TEE monitoring revealed lower levels of micro-embolic gas activity in the irrigation mist and CO<sub>2</sub> group, indicating a potential reduction in gas embolization risk. <i>Conclusions:</i> The irrigation mist and CO<sub>2</sub> system not only provides enhanced visualization during CABG but also significantly reduces the incidence of fibrillation during aortic de-clamping and micro-embolic gas activity. These findings suggest improved patient safety and outcomes, highlighting the irrigation mist and CO<sub>2</sub> system as a potentially safer alternative to direct CO<sub>2</sub> blowing in the context of myocardial revascularization.https://www.mdpi.com/1648-9144/60/12/2035coronary artery bypass grafting (CABG)ClearView™ Blower/MisterCO<sub>2</sub> blowermicro-embolic gas activitytransesophageal echocardiography (TEE)aortic de-clamping
spellingShingle Ignazio Condello
Giuseppe Speziale
Flavio Fiore
Giuseppe Nasso
Comparative Analysis of Irrigation Mist and CO<sub>2</sub> vs. Direct CO<sub>2</sub> Blower in On-Pump Coronary Artery Bypass Grafting Anastomosis: Efficacy, Efficiency, and Fibrillation upon De-Clamping and Micro-Embolic Gas Activity Incidence
Medicina
coronary artery bypass grafting (CABG)
ClearView™ Blower/Mister
CO<sub>2</sub> blower
micro-embolic gas activity
transesophageal echocardiography (TEE)
aortic de-clamping
title Comparative Analysis of Irrigation Mist and CO<sub>2</sub> vs. Direct CO<sub>2</sub> Blower in On-Pump Coronary Artery Bypass Grafting Anastomosis: Efficacy, Efficiency, and Fibrillation upon De-Clamping and Micro-Embolic Gas Activity Incidence
title_full Comparative Analysis of Irrigation Mist and CO<sub>2</sub> vs. Direct CO<sub>2</sub> Blower in On-Pump Coronary Artery Bypass Grafting Anastomosis: Efficacy, Efficiency, and Fibrillation upon De-Clamping and Micro-Embolic Gas Activity Incidence
title_fullStr Comparative Analysis of Irrigation Mist and CO<sub>2</sub> vs. Direct CO<sub>2</sub> Blower in On-Pump Coronary Artery Bypass Grafting Anastomosis: Efficacy, Efficiency, and Fibrillation upon De-Clamping and Micro-Embolic Gas Activity Incidence
title_full_unstemmed Comparative Analysis of Irrigation Mist and CO<sub>2</sub> vs. Direct CO<sub>2</sub> Blower in On-Pump Coronary Artery Bypass Grafting Anastomosis: Efficacy, Efficiency, and Fibrillation upon De-Clamping and Micro-Embolic Gas Activity Incidence
title_short Comparative Analysis of Irrigation Mist and CO<sub>2</sub> vs. Direct CO<sub>2</sub> Blower in On-Pump Coronary Artery Bypass Grafting Anastomosis: Efficacy, Efficiency, and Fibrillation upon De-Clamping and Micro-Embolic Gas Activity Incidence
title_sort comparative analysis of irrigation mist and co sub 2 sub vs direct co sub 2 sub blower in on pump coronary artery bypass grafting anastomosis efficacy efficiency and fibrillation upon de clamping and micro embolic gas activity incidence
topic coronary artery bypass grafting (CABG)
ClearView™ Blower/Mister
CO<sub>2</sub> blower
micro-embolic gas activity
transesophageal echocardiography (TEE)
aortic de-clamping
url https://www.mdpi.com/1648-9144/60/12/2035
work_keys_str_mv AT ignaziocondello comparativeanalysisofirrigationmistandcosub2subvsdirectcosub2subblowerinonpumpcoronaryarterybypassgraftinganastomosisefficacyefficiencyandfibrillationupondeclampingandmicroembolicgasactivityincidence
AT giuseppespeziale comparativeanalysisofirrigationmistandcosub2subvsdirectcosub2subblowerinonpumpcoronaryarterybypassgraftinganastomosisefficacyefficiencyandfibrillationupondeclampingandmicroembolicgasactivityincidence
AT flaviofiore comparativeanalysisofirrigationmistandcosub2subvsdirectcosub2subblowerinonpumpcoronaryarterybypassgraftinganastomosisefficacyefficiencyandfibrillationupondeclampingandmicroembolicgasactivityincidence
AT giuseppenasso comparativeanalysisofirrigationmistandcosub2subvsdirectcosub2subblowerinonpumpcoronaryarterybypassgraftinganastomosisefficacyefficiencyandfibrillationupondeclampingandmicroembolicgasactivityincidence