A Retrospective Trial Comparing Prediction Accuracy of Three Biometers in Short, Medium, and Long Eyes

Sam Multack,1 Nellie Plummer,1 Athanasios Marneris,1 Brad Hall2 1Multack Eye Care, Frankfort, IL, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Sam Multack, Multack Eye Care, 22200 Wolf Road, Frankfort, IL, 60423, USA, Tel +1-815-889-3333, Email smultack@mecvision.comPurpose: To assess the non-inf...

Full description

Saved in:
Bibliographic Details
Main Authors: Multack S, Plummer N, Marneris A, Hall B
Format: Article
Language:English
Published: Dove Medical Press 2025-02-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/a-retrospective-trial-comparing-prediction-accuracy-of-three-biometers-peer-reviewed-fulltext-article-OPTH
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850066542924922880
author Multack S
Plummer N
Marneris A
Hall B
author_facet Multack S
Plummer N
Marneris A
Hall B
author_sort Multack S
collection DOAJ
description Sam Multack,1 Nellie Plummer,1 Athanasios Marneris,1 Brad Hall2 1Multack Eye Care, Frankfort, IL, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Sam Multack, Multack Eye Care, 22200 Wolf Road, Frankfort, IL, 60423, USA, Tel +1-815-889-3333, Email smultack@mecvision.comPurpose: To assess the non-inferiority of mean absolute prediction error (APE) of the Argos (Movu, a Santec company) compared with the IOL Master 700 (Carl Zeiss Meditec AG) and Lenstar LS900 (Haag-Streit AG) biometers utilizing the Barrett Universal II (BUII) formula for power calculations in short, medium, and long axial length eyes.Methods: This was a retrospective chart review of prediction error from 3 biometers (Argos, IOLMaster 700, and Lenstar LS900). Biometer measurement order was determined using blocked randomization. Eligible charts were from eyes 50– 85 years old, axial length between 20.00 mm and 30.00 mm, and had IOL implantation with the AcrySof IQ monofocal IOL (SN60WF) and AcrySof toric IOL (SN6AT3, SN6AT4). Preoperative planning was done with the BUII formula on all biometers, with a target of plano. The primary outcome measure was the mean absolute prediction error for each biometer using BUII. Specifically, the non-inferiority of Argos compared to the IOLMaster 700 and Lenstar LS900 using a non-inferiority margin of 0.25 D.Results: The chart review identified 203 eyes from 123 patients. Mean APE for Argos overall and for each axial length group was non-inferior to that of IOLMaster 700 and Lenstar LS900. The overall mean APE was 0.25 ± 0.20 D for Argos compared to 0.25 ± 0.20 D for IOLMaster 700, and 0.25 ± 0.19 D for Lenstar LS900. The differences were not significant (p > 0.05). The percentages of eyes with APE 0.5 D or less were 90% for Argos, 89% for IOLMaster 700, and 89% for Lenstar LS900. The differences were not significant (p > 0.05).Conclusion: Overall mean APE was not significantly different with the Argos compared to IOLMaster 700 and Lenstar LS900 using the BUII formula, suggesting that the use of any of these devices can achieve good outcomes.Plain Language Summary: During cataract surgery, the natural lens inside the eye is removed and replaced with an artificial intraocular lens (IOL). A surgeon must select the most appropriate power for the IOL to maximize postoperative outcomes. Devices called biometers measure the eye and provide surgeons with built-in formulas to calculate the IOL power of implants. However, it can be challenging to determine the optimal IOL power to implant in eyes that are longer or shorter than average. The purpose of this study was to compare the predictive accuracy of three different biometers in long, medium, and short eyes. The results of this study indicate that the three biometers performed similarly well in long, medium and short eyes, suggesting that the use of any of these devices can achieve good outcomes.Keywords: argos, IOLMaster 700, Lenstar LS900, biometry
format Article
id doaj-art-97e67e19d72547dfbd3b8dbc4c4928ff
institution DOAJ
issn 1177-5483
language English
publishDate 2025-02-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj-art-97e67e19d72547dfbd3b8dbc4c4928ff2025-08-20T02:48:42ZengDove Medical PressClinical Ophthalmology1177-54832025-02-01Volume 19577583100249A Retrospective Trial Comparing Prediction Accuracy of Three Biometers in Short, Medium, and Long EyesMultack SPlummer NMarneris AHall BSam Multack,1 Nellie Plummer,1 Athanasios Marneris,1 Brad Hall2 1Multack Eye Care, Frankfort, IL, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Sam Multack, Multack Eye Care, 22200 Wolf Road, Frankfort, IL, 60423, USA, Tel +1-815-889-3333, Email smultack@mecvision.comPurpose: To assess the non-inferiority of mean absolute prediction error (APE) of the Argos (Movu, a Santec company) compared with the IOL Master 700 (Carl Zeiss Meditec AG) and Lenstar LS900 (Haag-Streit AG) biometers utilizing the Barrett Universal II (BUII) formula for power calculations in short, medium, and long axial length eyes.Methods: This was a retrospective chart review of prediction error from 3 biometers (Argos, IOLMaster 700, and Lenstar LS900). Biometer measurement order was determined using blocked randomization. Eligible charts were from eyes 50– 85 years old, axial length between 20.00 mm and 30.00 mm, and had IOL implantation with the AcrySof IQ monofocal IOL (SN60WF) and AcrySof toric IOL (SN6AT3, SN6AT4). Preoperative planning was done with the BUII formula on all biometers, with a target of plano. The primary outcome measure was the mean absolute prediction error for each biometer using BUII. Specifically, the non-inferiority of Argos compared to the IOLMaster 700 and Lenstar LS900 using a non-inferiority margin of 0.25 D.Results: The chart review identified 203 eyes from 123 patients. Mean APE for Argos overall and for each axial length group was non-inferior to that of IOLMaster 700 and Lenstar LS900. The overall mean APE was 0.25 ± 0.20 D for Argos compared to 0.25 ± 0.20 D for IOLMaster 700, and 0.25 ± 0.19 D for Lenstar LS900. The differences were not significant (p > 0.05). The percentages of eyes with APE 0.5 D or less were 90% for Argos, 89% for IOLMaster 700, and 89% for Lenstar LS900. The differences were not significant (p > 0.05).Conclusion: Overall mean APE was not significantly different with the Argos compared to IOLMaster 700 and Lenstar LS900 using the BUII formula, suggesting that the use of any of these devices can achieve good outcomes.Plain Language Summary: During cataract surgery, the natural lens inside the eye is removed and replaced with an artificial intraocular lens (IOL). A surgeon must select the most appropriate power for the IOL to maximize postoperative outcomes. Devices called biometers measure the eye and provide surgeons with built-in formulas to calculate the IOL power of implants. However, it can be challenging to determine the optimal IOL power to implant in eyes that are longer or shorter than average. The purpose of this study was to compare the predictive accuracy of three different biometers in long, medium, and short eyes. The results of this study indicate that the three biometers performed similarly well in long, medium and short eyes, suggesting that the use of any of these devices can achieve good outcomes.Keywords: argos, IOLMaster 700, Lenstar LS900, biometryhttps://www.dovepress.com/a-retrospective-trial-comparing-prediction-accuracy-of-three-biometers-peer-reviewed-fulltext-article-OPTHargosiolmaster 700lenstar ls900biometry
spellingShingle Multack S
Plummer N
Marneris A
Hall B
A Retrospective Trial Comparing Prediction Accuracy of Three Biometers in Short, Medium, and Long Eyes
Clinical Ophthalmology
argos
iolmaster 700
lenstar ls900
biometry
title A Retrospective Trial Comparing Prediction Accuracy of Three Biometers in Short, Medium, and Long Eyes
title_full A Retrospective Trial Comparing Prediction Accuracy of Three Biometers in Short, Medium, and Long Eyes
title_fullStr A Retrospective Trial Comparing Prediction Accuracy of Three Biometers in Short, Medium, and Long Eyes
title_full_unstemmed A Retrospective Trial Comparing Prediction Accuracy of Three Biometers in Short, Medium, and Long Eyes
title_short A Retrospective Trial Comparing Prediction Accuracy of Three Biometers in Short, Medium, and Long Eyes
title_sort retrospective trial comparing prediction accuracy of three biometers in short medium and long eyes
topic argos
iolmaster 700
lenstar ls900
biometry
url https://www.dovepress.com/a-retrospective-trial-comparing-prediction-accuracy-of-three-biometers-peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT multacks aretrospectivetrialcomparingpredictionaccuracyofthreebiometersinshortmediumandlongeyes
AT plummern aretrospectivetrialcomparingpredictionaccuracyofthreebiometersinshortmediumandlongeyes
AT marnerisa aretrospectivetrialcomparingpredictionaccuracyofthreebiometersinshortmediumandlongeyes
AT hallb aretrospectivetrialcomparingpredictionaccuracyofthreebiometersinshortmediumandlongeyes
AT multacks retrospectivetrialcomparingpredictionaccuracyofthreebiometersinshortmediumandlongeyes
AT plummern retrospectivetrialcomparingpredictionaccuracyofthreebiometersinshortmediumandlongeyes
AT marnerisa retrospectivetrialcomparingpredictionaccuracyofthreebiometersinshortmediumandlongeyes
AT hallb retrospectivetrialcomparingpredictionaccuracyofthreebiometersinshortmediumandlongeyes