Operation Characteristics and Security Control Measures of UHV Loop Network with Multi-Hierarchical DC Infeed after Breaking

The operation of a provincial UHV AC loop network provides conditions for hierarchical access and full power accommodation of multiple UHV DC systems, and also increases the coupling strength between UHV AC and UHV DC, and between 1000 kV/500 kV AC power grids at the receiving end. To ensure the rel...

Full description

Saved in:
Bibliographic Details
Main Authors: Shuaitao BAI, Dezhi CHEN, Shiying MA, Qing DONG, Wei TANG, Ping JI, Cheng YANG, Xikai JIANG
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2020-10-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201909024
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850030034245386240
author Shuaitao BAI
Dezhi CHEN
Shiying MA
Qing DONG
Wei TANG
Ping JI
Cheng YANG
Xikai JIANG
author_facet Shuaitao BAI
Dezhi CHEN
Shiying MA
Qing DONG
Wei TANG
Ping JI
Cheng YANG
Xikai JIANG
author_sort Shuaitao BAI
collection DOAJ
description The operation of a provincial UHV AC loop network provides conditions for hierarchical access and full power accommodation of multiple UHV DC systems, and also increases the coupling strength between UHV AC and UHV DC, and between 1000 kV/500 kV AC power grids at the receiving end. To ensure the reliable operation of UHV AC/DC power grids after line fault occurs, simulation is used to analyze the voltage stability characteristics of the coupled AC and DC systems after breaking of the 1000 kV UHV loop network, and the thermal stability characteristics of the power system when large power transfers to the 500 kV power grid after breaking, and the causes for voltage stability and thermo-stability problems are studied. In order to reduce the amount of security control measures, a unified multi-resource co-control optimization model is established for controlling the two operational problems, with consideration of the sensitivity and priority of multiple control methods such as DC modulation and load shedding. And a control-cost-based heuristic optimization method of constant-step gradient descent is proposed to obtain the co-control measures. It is verified through simulation of an actual power grid that the proposed controlling method can effectively reduce the amount of prevention and control measures.
format Article
id doaj-art-97a5f599d9954c3fbf0669f2e1c30b74
institution DOAJ
issn 1004-9649
language zho
publishDate 2020-10-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-97a5f599d9954c3fbf0669f2e1c30b742025-08-20T02:59:19ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492020-10-01531020621410.11930/j.issn.1004-9649.201909024zgdl-53-7-baishuaitaoOperation Characteristics and Security Control Measures of UHV Loop Network with Multi-Hierarchical DC Infeed after BreakingShuaitao BAI0Dezhi CHEN1Shiying MA2Qing DONG3Wei TANG4Ping JI5Cheng YANG6Xikai JIANG7Electrical and Electronic Engineering College of North China Electric Power University, Baoding 071003, ChinaChina Electric Power Research Institute, Beijing 100192, ChinaChina Electric Power Research Institute, Beijing 100192, ChinaElectrical and Electronic Engineering College of North China Electric Power University, Baoding 071003, ChinaState Grid Anhui Electric Power Co., Ltd., Hefei 230061, ChinaChina Electric Power Research Institute, Beijing 100192, ChinaState Grid Anhui Electric Power Co., Ltd., Hefei 230061, ChinaState Grid Shenyang Electric Power Supply Company, Shenyang 110021, ChinaThe operation of a provincial UHV AC loop network provides conditions for hierarchical access and full power accommodation of multiple UHV DC systems, and also increases the coupling strength between UHV AC and UHV DC, and between 1000 kV/500 kV AC power grids at the receiving end. To ensure the reliable operation of UHV AC/DC power grids after line fault occurs, simulation is used to analyze the voltage stability characteristics of the coupled AC and DC systems after breaking of the 1000 kV UHV loop network, and the thermal stability characteristics of the power system when large power transfers to the 500 kV power grid after breaking, and the causes for voltage stability and thermo-stability problems are studied. In order to reduce the amount of security control measures, a unified multi-resource co-control optimization model is established for controlling the two operational problems, with consideration of the sensitivity and priority of multiple control methods such as DC modulation and load shedding. And a control-cost-based heuristic optimization method of constant-step gradient descent is proposed to obtain the co-control measures. It is verified through simulation of an actual power grid that the proposed controlling method can effectively reduce the amount of prevention and control measures.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201909024uhvacloop network structureuhvdcthermal stabilityvoltage stabilitycoupling characteristicscoordinated control
spellingShingle Shuaitao BAI
Dezhi CHEN
Shiying MA
Qing DONG
Wei TANG
Ping JI
Cheng YANG
Xikai JIANG
Operation Characteristics and Security Control Measures of UHV Loop Network with Multi-Hierarchical DC Infeed after Breaking
Zhongguo dianli
uhvac
loop network structure
uhvdc
thermal stability
voltage stability
coupling characteristics
coordinated control
title Operation Characteristics and Security Control Measures of UHV Loop Network with Multi-Hierarchical DC Infeed after Breaking
title_full Operation Characteristics and Security Control Measures of UHV Loop Network with Multi-Hierarchical DC Infeed after Breaking
title_fullStr Operation Characteristics and Security Control Measures of UHV Loop Network with Multi-Hierarchical DC Infeed after Breaking
title_full_unstemmed Operation Characteristics and Security Control Measures of UHV Loop Network with Multi-Hierarchical DC Infeed after Breaking
title_short Operation Characteristics and Security Control Measures of UHV Loop Network with Multi-Hierarchical DC Infeed after Breaking
title_sort operation characteristics and security control measures of uhv loop network with multi hierarchical dc infeed after breaking
topic uhvac
loop network structure
uhvdc
thermal stability
voltage stability
coupling characteristics
coordinated control
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201909024
work_keys_str_mv AT shuaitaobai operationcharacteristicsandsecuritycontrolmeasuresofuhvloopnetworkwithmultihierarchicaldcinfeedafterbreaking
AT dezhichen operationcharacteristicsandsecuritycontrolmeasuresofuhvloopnetworkwithmultihierarchicaldcinfeedafterbreaking
AT shiyingma operationcharacteristicsandsecuritycontrolmeasuresofuhvloopnetworkwithmultihierarchicaldcinfeedafterbreaking
AT qingdong operationcharacteristicsandsecuritycontrolmeasuresofuhvloopnetworkwithmultihierarchicaldcinfeedafterbreaking
AT weitang operationcharacteristicsandsecuritycontrolmeasuresofuhvloopnetworkwithmultihierarchicaldcinfeedafterbreaking
AT pingji operationcharacteristicsandsecuritycontrolmeasuresofuhvloopnetworkwithmultihierarchicaldcinfeedafterbreaking
AT chengyang operationcharacteristicsandsecuritycontrolmeasuresofuhvloopnetworkwithmultihierarchicaldcinfeedafterbreaking
AT xikaijiang operationcharacteristicsandsecuritycontrolmeasuresofuhvloopnetworkwithmultihierarchicaldcinfeedafterbreaking