Quantification of FDG in the spinal cord using PET/MRI
BackgroundIn this study, we investigate the impact of MR-derived attenuation maps and limited detector resolution on the quantification of positron emission tomography (PET) activity uptake in the spinal cord during PET/MRI. This was performed by simulating [18F]FDG PET data in the neck and thorax a...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Frontiers Media S.A.
2025-08-01
|
| Series: | Frontiers in Nuclear Medicine |
| Subjects: | |
| Online Access: | https://www.frontiersin.org/articles/10.3389/fnume.2025.1646662/full |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849222445267943424 |
|---|---|
| author | Eve Lennie Steven Sourbron Nigel Hoggard Nigel Hoggard Thomas Jenkins Thomas Jenkins Charalampos Tsoumpas |
| author_facet | Eve Lennie Steven Sourbron Nigel Hoggard Nigel Hoggard Thomas Jenkins Thomas Jenkins Charalampos Tsoumpas |
| author_sort | Eve Lennie |
| collection | DOAJ |
| description | BackgroundIn this study, we investigate the impact of MR-derived attenuation maps and limited detector resolution on the quantification of positron emission tomography (PET) activity uptake in the spinal cord during PET/MRI. This was performed by simulating [18F]FDG PET data in the neck and thorax and then modifying the attenuation map to remove bone features. We then compared Ordered Subset Expectation Maximisation-reconstructed images to those with full attenuation correction. This simulation was performed at two detector resolutions of 2.1 and 4.4 mm. Acquisitions from a clinical study were then used to assess the ability of point spread function (PSF) modelling and time-of-flight (TOF) corrections, as implemented on the SIGNA PET/MR scanner (GE HealthCare), to correct for these quantification errors. For comparison, mean uptake was measured in regions of interest at each vertebral position along the spinal cord.ResultsSimulation results showed a decreasing pattern of uptake from the cervical to the thoracic spinal cord. When bone was not included in attenuation correction, the mean uptake decreased by 3%–10.4%. This difference in measured uptake was 6.4%–23.9% in images simulated at a detector resolution representative of a clinical PET/MRI scanner. At a detector resolution of 4.4 mm, a 32.2% decrease in uptake was measured compared to the 2.1 mm simulation. In patient data, introducing vertebral bone to the attenuation correction pseudo-CT led to a 1.8%–18.3% difference in SUVmean in the spinal cord. Applying PSF modelling did not lead to any statistically significant changes. TOF correction reduces the difference in SUVmean between data attenuation corrected with and without vertebral bone to 4.3%–7%. TOF Q.Clear images with beta = 100 showed the smallest difference between attenuation correction approaches at 0.6%–5.2%.ConclusionIgnoring bone during image reconstruction in PET/MRI reduces the activity measured during quantification of the spinal cord; however, the partial volume effect has a greater impact on reducing measured uptake in lower-resolution data. While time-of-flight correction goes somewhat resolves these quantification errors, further research is needed into partial volume correction. |
| format | Article |
| id | doaj-art-973e0a48e2254b1b81555973bb4676d4 |
| institution | Kabale University |
| issn | 2673-8880 |
| language | English |
| publishDate | 2025-08-01 |
| publisher | Frontiers Media S.A. |
| record_format | Article |
| series | Frontiers in Nuclear Medicine |
| spelling | doaj-art-973e0a48e2254b1b81555973bb4676d42025-08-26T05:27:51ZengFrontiers Media S.A.Frontiers in Nuclear Medicine2673-88802025-08-01510.3389/fnume.2025.16466621646662Quantification of FDG in the spinal cord using PET/MRIEve Lennie0Steven Sourbron1Nigel Hoggard2Nigel Hoggard3Thomas Jenkins4Thomas Jenkins5Charalampos Tsoumpas6Division of Clinical Medicine, University of Sheffield, Sheffield, United KingdomDivision of Clinical Medicine, University of Sheffield, Sheffield, United KingdomDivision of Clinical Medicine, University of Sheffield, Sheffield, United KingdomDepartment of Radiology, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United KingdomDivision of Clinical Medicine, University of Sheffield, Sheffield, United KingdomJoondalup Healthcare Campus and Curtin University, Perth, WA, AustraliaDepartment of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, NetherlandsBackgroundIn this study, we investigate the impact of MR-derived attenuation maps and limited detector resolution on the quantification of positron emission tomography (PET) activity uptake in the spinal cord during PET/MRI. This was performed by simulating [18F]FDG PET data in the neck and thorax and then modifying the attenuation map to remove bone features. We then compared Ordered Subset Expectation Maximisation-reconstructed images to those with full attenuation correction. This simulation was performed at two detector resolutions of 2.1 and 4.4 mm. Acquisitions from a clinical study were then used to assess the ability of point spread function (PSF) modelling and time-of-flight (TOF) corrections, as implemented on the SIGNA PET/MR scanner (GE HealthCare), to correct for these quantification errors. For comparison, mean uptake was measured in regions of interest at each vertebral position along the spinal cord.ResultsSimulation results showed a decreasing pattern of uptake from the cervical to the thoracic spinal cord. When bone was not included in attenuation correction, the mean uptake decreased by 3%–10.4%. This difference in measured uptake was 6.4%–23.9% in images simulated at a detector resolution representative of a clinical PET/MRI scanner. At a detector resolution of 4.4 mm, a 32.2% decrease in uptake was measured compared to the 2.1 mm simulation. In patient data, introducing vertebral bone to the attenuation correction pseudo-CT led to a 1.8%–18.3% difference in SUVmean in the spinal cord. Applying PSF modelling did not lead to any statistically significant changes. TOF correction reduces the difference in SUVmean between data attenuation corrected with and without vertebral bone to 4.3%–7%. TOF Q.Clear images with beta = 100 showed the smallest difference between attenuation correction approaches at 0.6%–5.2%.ConclusionIgnoring bone during image reconstruction in PET/MRI reduces the activity measured during quantification of the spinal cord; however, the partial volume effect has a greater impact on reducing measured uptake in lower-resolution data. While time-of-flight correction goes somewhat resolves these quantification errors, further research is needed into partial volume correction.https://www.frontiersin.org/articles/10.3389/fnume.2025.1646662/fullPET/MRIpositron emission tomographymagnetic resonance imagingspinal cordneurologyneuroimaging |
| spellingShingle | Eve Lennie Steven Sourbron Nigel Hoggard Nigel Hoggard Thomas Jenkins Thomas Jenkins Charalampos Tsoumpas Quantification of FDG in the spinal cord using PET/MRI Frontiers in Nuclear Medicine PET/MRI positron emission tomography magnetic resonance imaging spinal cord neurology neuroimaging |
| title | Quantification of FDG in the spinal cord using PET/MRI |
| title_full | Quantification of FDG in the spinal cord using PET/MRI |
| title_fullStr | Quantification of FDG in the spinal cord using PET/MRI |
| title_full_unstemmed | Quantification of FDG in the spinal cord using PET/MRI |
| title_short | Quantification of FDG in the spinal cord using PET/MRI |
| title_sort | quantification of fdg in the spinal cord using pet mri |
| topic | PET/MRI positron emission tomography magnetic resonance imaging spinal cord neurology neuroimaging |
| url | https://www.frontiersin.org/articles/10.3389/fnume.2025.1646662/full |
| work_keys_str_mv | AT evelennie quantificationoffdginthespinalcordusingpetmri AT stevensourbron quantificationoffdginthespinalcordusingpetmri AT nigelhoggard quantificationoffdginthespinalcordusingpetmri AT nigelhoggard quantificationoffdginthespinalcordusingpetmri AT thomasjenkins quantificationoffdginthespinalcordusingpetmri AT thomasjenkins quantificationoffdginthespinalcordusingpetmri AT charalampostsoumpas quantificationoffdginthespinalcordusingpetmri |