Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation
Conclusions: The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2025-01-01
|
| Series: | Journal of Ophthalmology |
| Online Access: | http://dx.doi.org/10.1155/joph/6959314 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850114024051572736 |
|---|---|
| author | Beltrán-Murcia J. Álvarez-Rementería Capelo L. Blázquez-Sánchez V. |
| author_facet | Beltrán-Murcia J. Álvarez-Rementería Capelo L. Blázquez-Sánchez V. |
| author_sort | Beltrán-Murcia J. |
| collection | DOAJ |
| description | Conclusions: The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens. |
| format | Article |
| id | doaj-art-96ac9126f0cd4be58b6d3ba9ddc114a8 |
| institution | OA Journals |
| issn | 2090-0058 |
| language | English |
| publishDate | 2025-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | Journal of Ophthalmology |
| spelling | doaj-art-96ac9126f0cd4be58b6d3ba9ddc114a82025-08-20T02:36:59ZengWileyJournal of Ophthalmology2090-00582025-01-01202510.1155/joph/6959314Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens ImplantationBeltrán-Murcia J.0Álvarez-Rementería Capelo L.1Blázquez-Sánchez V.2Department of Optometry and VisionClínica RementeríaDepartment of Optometry and VisionConclusions: The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.http://dx.doi.org/10.1155/joph/6959314 |
| spellingShingle | Beltrán-Murcia J. Álvarez-Rementería Capelo L. Blázquez-Sánchez V. Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation Journal of Ophthalmology |
| title | Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation |
| title_full | Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation |
| title_fullStr | Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation |
| title_full_unstemmed | Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation |
| title_short | Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation |
| title_sort | correlation of biometric parameters with endothelial distance in evo icl phakic lens implantation |
| url | http://dx.doi.org/10.1155/joph/6959314 |
| work_keys_str_mv | AT beltranmurciaj correlationofbiometricparameterswithendothelialdistanceinevoiclphakiclensimplantation AT alvarezrementeriacapelol correlationofbiometricparameterswithendothelialdistanceinevoiclphakiclensimplantation AT blazquezsanchezv correlationofbiometricparameterswithendothelialdistanceinevoiclphakiclensimplantation |