Development diagnostic device of pin insulators

The article proposes an invention to diagnose a damaged insulator under the operating voltage of the power line (VLEP), using leakage current control. There is made a prototype, experiments are carried out. The leakage current removed from the shunt design is converted to a digital signal for p...

Full description

Saved in:
Bibliographic Details
Main Authors: N. A. Tereshchenko, V. Yu. Miroshnik, M. A. Kholmov, K. I. Nikitin, B. N. Kovrizhin
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2021-06-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2021/%E2%84%96%203%20(177)%20(%D0%9E%D0%9D%D0%92)/70-74%20%D0%A2%D0%B5%D1%80%D0%B5%D1%89%D0%B5%D0%BD%D0%BA%D0%BE%20%D0%9D.%20%D0%90.,%20%D0%9C%D0%B8%D1%80%D0%BE%D1%88%D0%BD%D0%B8%D0%BA%20%D0%92.%20%D0%AE.,%20%D0%A5%D0%BE%D0%BB%D0%BC%D0%BE%D0%B2%20%D0%9C.%20%D0%90.%20%D0%B8%20%D0%B4%D1%80..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832572757097840640
author N. A. Tereshchenko
V. Yu. Miroshnik
M. A. Kholmov
K. I. Nikitin
B. N. Kovrizhin
author_facet N. A. Tereshchenko
V. Yu. Miroshnik
M. A. Kholmov
K. I. Nikitin
B. N. Kovrizhin
author_sort N. A. Tereshchenko
collection DOAJ
description The article proposes an invention to diagnose a damaged insulator under the operating voltage of the power line (VLEP), using leakage current control. There is made a prototype, experiments are carried out. The leakage current removed from the shunt design is converted to a digital signal for processing, transmission and further processing on the substation control room. The controlled leakage current corresponds to the magnitude of the insulation resistance of the insulator.
format Article
id doaj-art-946d9f1408e645db9cae5f913392e98f
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2021-06-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-946d9f1408e645db9cae5f913392e98f2025-02-02T07:58:34ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412021-06-013 (177)707410.25206/1813-8225-2021-177-70-74Development diagnostic device of pin insulatorsN. A. Tereshchenko0V. Yu. Miroshnik1M. A. Kholmov2K. I. Nikitin3B. N. Kovrizhin4Omsk State Technical UniversityOmsk State Technical UniversityOmsk State Technical UniversityOmsk State Technical UniversityOmsk State Technical UniversityThe article proposes an invention to diagnose a damaged insulator under the operating voltage of the power line (VLEP), using leakage current control. There is made a prototype, experiments are carried out. The leakage current removed from the shunt design is converted to a digital signal for processing, transmission and further processing on the substation control room. The controlled leakage current corresponds to the magnitude of the insulation resistance of the insulator.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2021/%E2%84%96%203%20(177)%20(%D0%9E%D0%9D%D0%92)/70-74%20%D0%A2%D0%B5%D1%80%D0%B5%D1%89%D0%B5%D0%BD%D0%BA%D0%BE%20%D0%9D.%20%D0%90.,%20%D0%9C%D0%B8%D1%80%D0%BE%D1%88%D0%BD%D0%B8%D0%BA%20%D0%92.%20%D0%AE.,%20%D0%A5%D0%BE%D0%BB%D0%BC%D0%BE%D0%B2%20%D0%9C.%20%D0%90.%20%D0%B8%20%D0%B4%D1%80..pdfleakage currentpin insulatorledalternating voltage
spellingShingle N. A. Tereshchenko
V. Yu. Miroshnik
M. A. Kholmov
K. I. Nikitin
B. N. Kovrizhin
Development diagnostic device of pin insulators
Омский научный вестник
leakage current
pin insulator
led
alternating voltage
title Development diagnostic device of pin insulators
title_full Development diagnostic device of pin insulators
title_fullStr Development diagnostic device of pin insulators
title_full_unstemmed Development diagnostic device of pin insulators
title_short Development diagnostic device of pin insulators
title_sort development diagnostic device of pin insulators
topic leakage current
pin insulator
led
alternating voltage
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2021/%E2%84%96%203%20(177)%20(%D0%9E%D0%9D%D0%92)/70-74%20%D0%A2%D0%B5%D1%80%D0%B5%D1%89%D0%B5%D0%BD%D0%BA%D0%BE%20%D0%9D.%20%D0%90.,%20%D0%9C%D0%B8%D1%80%D0%BE%D1%88%D0%BD%D0%B8%D0%BA%20%D0%92.%20%D0%AE.,%20%D0%A5%D0%BE%D0%BB%D0%BC%D0%BE%D0%B2%20%D0%9C.%20%D0%90.%20%D0%B8%20%D0%B4%D1%80..pdf
work_keys_str_mv AT natereshchenko developmentdiagnosticdeviceofpininsulators
AT vyumiroshnik developmentdiagnosticdeviceofpininsulators
AT makholmov developmentdiagnosticdeviceofpininsulators
AT kinikitin developmentdiagnosticdeviceofpininsulators
AT bnkovrizhin developmentdiagnosticdeviceofpininsulators