Finite Element Analysis of the Bearing Component of Total Ankle Replacement Implants during the Stance Phase of the Gait Cycle

Total ankle arthroplasty (TAA) is a motion-preserving treatment for end-stage ankle arthritis. An effective tool for analyzing these implants’ mechanical performance and longevity in silico is finite element analysis (FEA). An FEA in ABAQUS was used to statically analyze the mechanical behavior of t...

Full description

Saved in:
Bibliographic Details
Main Authors: Timothy S. Jain, Mohammad Noori, Joseph J. Rencis, Amanda Anderson, Naudereh Noori, Scott Hazelwood
Format: Article
Language:English
Published: MDPI AG 2024-09-01
Series:BioMedInformatics
Subjects:
Online Access:https://www.mdpi.com/2673-7426/4/3/107
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850258647378034688
author Timothy S. Jain
Mohammad Noori
Joseph J. Rencis
Amanda Anderson
Naudereh Noori
Scott Hazelwood
author_facet Timothy S. Jain
Mohammad Noori
Joseph J. Rencis
Amanda Anderson
Naudereh Noori
Scott Hazelwood
author_sort Timothy S. Jain
collection DOAJ
description Total ankle arthroplasty (TAA) is a motion-preserving treatment for end-stage ankle arthritis. An effective tool for analyzing these implants’ mechanical performance and longevity in silico is finite element analysis (FEA). An FEA in ABAQUS was used to statically analyze the mechanical behavior of the ultra-high-molecular-weight polyethylene (UHMWPE) bearing component at varying dorsiflexion/plantarflexion ankle angles and axial loading conditions during the stance phase of the gait cycle for a single cycle. The von Mises stress and contact pressure were examined on the articulating surface of the bearing component in two newly installed fixed-bearing TAA implants (Wright Medical INBONE II and Exactech Vantage). Six different FEA models of variable ankle compressive load levels and ankle angle positions, for the varying subphases of the stance phase of the gait cycle, were created. The components in these models were constrained to be conducive to the bone–implant interface, where implant loosening occurs. Our results showed that the von Mises stress and contact pressure distributions increased as the compressive load increased. The highest stress was noted at dorsiflexion angles > 15°, in areas where the UHMWPE liner was thinnest, at the edges of the talar and UHMWPE components, and during the terminal stance phase of the gait cycle. This static structural analysis highlighted these failure regions are susceptible to yielding and wear and indicated stress magnitudes that are in agreement (within 25%) with those in previous static structural TAA FEAs. The mechanical wear of the UHMWPE bearing component in TAA can lead to aseptic loosening and peri-implant cyst formation over time, requiring surgical revision. This study provides ankle replacement manufacturers and orthopedic surgeons with a better understanding of the stress response and contact pressure sustained by TAA implants, which is critical to optimizing implant longevity and improving patient care.
format Article
id doaj-art-9463df901f0e4ab892bfeb6246331e2f
institution OA Journals
issn 2673-7426
language English
publishDate 2024-09-01
publisher MDPI AG
record_format Article
series BioMedInformatics
spelling doaj-art-9463df901f0e4ab892bfeb6246331e2f2025-08-20T01:56:05ZengMDPI AGBioMedInformatics2673-74262024-09-01431949197810.3390/biomedinformatics4030107Finite Element Analysis of the Bearing Component of Total Ankle Replacement Implants during the Stance Phase of the Gait CycleTimothy S. Jain0Mohammad Noori1Joseph J. Rencis2Amanda Anderson3Naudereh Noori4Scott Hazelwood5Department of Mechanical Engineering, California Polytechnic State University, San Luis Obispo, CA 93407, USADepartment of Mechanical Engineering, California Polytechnic State University, San Luis Obispo, CA 93407, USASchool of Engineering, College of Aviation, Embry-Riddle Aeronautical University World Campus, 1 Aerospace Boulevard, Daytona Beach, FL 32114, USADepartment of Orthopedic Surgery, University of California-Irvine, Orange, CA 92868, USADepartment of Orthopedic Surgery, University of California-Irvine, Orange, CA 92868, USABiomedical Engineering, California Polytechnic State University, San Luis Obispo, CA 93407, USATotal ankle arthroplasty (TAA) is a motion-preserving treatment for end-stage ankle arthritis. An effective tool for analyzing these implants’ mechanical performance and longevity in silico is finite element analysis (FEA). An FEA in ABAQUS was used to statically analyze the mechanical behavior of the ultra-high-molecular-weight polyethylene (UHMWPE) bearing component at varying dorsiflexion/plantarflexion ankle angles and axial loading conditions during the stance phase of the gait cycle for a single cycle. The von Mises stress and contact pressure were examined on the articulating surface of the bearing component in two newly installed fixed-bearing TAA implants (Wright Medical INBONE II and Exactech Vantage). Six different FEA models of variable ankle compressive load levels and ankle angle positions, for the varying subphases of the stance phase of the gait cycle, were created. The components in these models were constrained to be conducive to the bone–implant interface, where implant loosening occurs. Our results showed that the von Mises stress and contact pressure distributions increased as the compressive load increased. The highest stress was noted at dorsiflexion angles > 15°, in areas where the UHMWPE liner was thinnest, at the edges of the talar and UHMWPE components, and during the terminal stance phase of the gait cycle. This static structural analysis highlighted these failure regions are susceptible to yielding and wear and indicated stress magnitudes that are in agreement (within 25%) with those in previous static structural TAA FEAs. The mechanical wear of the UHMWPE bearing component in TAA can lead to aseptic loosening and peri-implant cyst formation over time, requiring surgical revision. This study provides ankle replacement manufacturers and orthopedic surgeons with a better understanding of the stress response and contact pressure sustained by TAA implants, which is critical to optimizing implant longevity and improving patient care.https://www.mdpi.com/2673-7426/4/3/107bioengineeringtotal ankle replacement (TAR)bearing componentUHMWPEfinite element analysisvon Mises stress
spellingShingle Timothy S. Jain
Mohammad Noori
Joseph J. Rencis
Amanda Anderson
Naudereh Noori
Scott Hazelwood
Finite Element Analysis of the Bearing Component of Total Ankle Replacement Implants during the Stance Phase of the Gait Cycle
BioMedInformatics
bioengineering
total ankle replacement (TAR)
bearing component
UHMWPE
finite element analysis
von Mises stress
title Finite Element Analysis of the Bearing Component of Total Ankle Replacement Implants during the Stance Phase of the Gait Cycle
title_full Finite Element Analysis of the Bearing Component of Total Ankle Replacement Implants during the Stance Phase of the Gait Cycle
title_fullStr Finite Element Analysis of the Bearing Component of Total Ankle Replacement Implants during the Stance Phase of the Gait Cycle
title_full_unstemmed Finite Element Analysis of the Bearing Component of Total Ankle Replacement Implants during the Stance Phase of the Gait Cycle
title_short Finite Element Analysis of the Bearing Component of Total Ankle Replacement Implants during the Stance Phase of the Gait Cycle
title_sort finite element analysis of the bearing component of total ankle replacement implants during the stance phase of the gait cycle
topic bioengineering
total ankle replacement (TAR)
bearing component
UHMWPE
finite element analysis
von Mises stress
url https://www.mdpi.com/2673-7426/4/3/107
work_keys_str_mv AT timothysjain finiteelementanalysisofthebearingcomponentoftotalanklereplacementimplantsduringthestancephaseofthegaitcycle
AT mohammadnoori finiteelementanalysisofthebearingcomponentoftotalanklereplacementimplantsduringthestancephaseofthegaitcycle
AT josephjrencis finiteelementanalysisofthebearingcomponentoftotalanklereplacementimplantsduringthestancephaseofthegaitcycle
AT amandaanderson finiteelementanalysisofthebearingcomponentoftotalanklereplacementimplantsduringthestancephaseofthegaitcycle
AT nauderehnoori finiteelementanalysisofthebearingcomponentoftotalanklereplacementimplantsduringthestancephaseofthegaitcycle
AT scotthazelwood finiteelementanalysisofthebearingcomponentoftotalanklereplacementimplantsduringthestancephaseofthegaitcycle