Failure Analysis on the Impressed Current Cathodic Protection of Wharf Steel Pipe Pile
 The steel pipe piles of a coal wharf were protected by an impressed current cathodic protection system. After construction, it was found that the cathodic protection system was in a state of under - protection regardless of the adjustment of the output current. Therefore, the circuit lay...
Saved in:
| Main Author: | LI Hai - hong, DENG Chun - lin, FANG Xiang |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Department of Materials Protection
2021-10-01
|
| Series: | Cailiao Baohu |
| Subjects: | |
| Online Access: | http://www.mat-pro.com/fileup/1001-1560/PDF/20211028.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Study on Numerical Simulation of Influence of Sea Mud Resistivity on the Cathodic Protection Effect for Steel Pipe Pile
by: FANG Xiang, ZHANG Dong - fang, FAN Zhi - hong, XIONG Jian - bo
Published: (2021-03-01) -
Application of Oilfield Casing Cathodic Protection Technology
by: LIU Li, LIU Jie, ZHANG Yong - qiang, YANG Zhi - gang, LV Shuo, TA Chuan, HUANG Guo - sheng
Published: (2021-03-01) -
A Comparative Analysis of Axial Bearing Behaviour in Steel Pipe Piles and PHC Piles for Port Engineering
by: Runze Zhang, et al.
Published: (2025-08-01) -
Non-Uniform Corrosion Monitoring of Steel Pipes Using Distributed Optical Fiber Sensors in the Fluctuation Zone of a Coastal Wharf
by: Jiguo Chen, et al.
Published: (2025-05-01) -
Mechanical characteristics and calculation method of static pressure pile installation for PHC pipe piles in sandy soil foundation with pebble interlayer
by: Xiannian Zhou, et al.
Published: (2025-04-01)