An improvised two in one syringe suction drain for surgeries of extremities

Use of an improvised two in one syringe suction drain is being presented for a case with two adjacent non-communicating surgical wounds following release of Duputryn′s contracture primarily involving the longitudinal band of the palmar fascia of the hand, in line with the middle and ring finger. Ins...

Full description

Saved in:
Bibliographic Details
Main Authors: J B Kamath, R K Kamath, H Bansal
Format: Article
Language:English
Published: Thieme Medical and Scientific Publishers Pvt. Ltd. 2005-07-01
Series:Indian Journal of Plastic Surgery
Subjects:
Online Access:http://www.thieme-connect.de/DOI/DOI?10.1055/s-0039-1699100
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Use of an improvised two in one syringe suction drain is being presented for a case with two adjacent non-communicating surgical wounds following release of Duputryn′s contracture primarily involving the longitudinal band of the palmar fascia of the hand, in line with the middle and ring finger. Instead of using two separate closed suction drainage system we modified our method by using a 3 way cannula which could accept 2 draining tubes to be connected to one 50cc syringe with negative suction pressure.