An effective approach for correlating Na+ concentrations with sweating rates in wearable sweat sensing platform

Accurately correlating the sweating rate and the concentration of biomarkers in sweat is essential in many sweat-based diagnostic applications. These two measurements are always done simultaneously in wearable sweat sensing platforms. However, concentration measurements of biomarkers are always dela...

Full description

Saved in:
Bibliographic Details
Main Authors: Anwei He, Xiaohe Wang, Liang Zhang, Haolong Zhang, Xingli Xu, Chenyang Yu, Yongquan Ma, Wei Wei, Pengfei Niu
Format: Article
Language:English
Published: AIP Publishing LLC 2025-03-01
Series:Nanotechnology and Precision Engineering
Online Access:http://dx.doi.org/10.1063/10.0028758
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850235191585406976
author Anwei He
Xiaohe Wang
Liang Zhang
Haolong Zhang
Xingli Xu
Chenyang Yu
Yongquan Ma
Wei Wei
Pengfei Niu
author_facet Anwei He
Xiaohe Wang
Liang Zhang
Haolong Zhang
Xingli Xu
Chenyang Yu
Yongquan Ma
Wei Wei
Pengfei Niu
author_sort Anwei He
collection DOAJ
description Accurately correlating the sweating rate and the concentration of biomarkers in sweat is essential in many sweat-based diagnostic applications. These two measurements are always done simultaneously in wearable sweat sensing platforms. However, concentration measurements of biomarkers are always delayed on the timeline compared with their production, whereas there is no such delay for sweating rate. Thus, a timeline mismatch exists between these two measurements. This means that the concentration vs rate correlation constructed on the basis of such measurements will deviate from the actual correlation. This study demonstrates the existence of this mismatch and explains its cause using sweat Na+ measurements. It also proposes an effective approach that applies a point-by-point compensation for the delay between Na+ measurements and the real-time sweating rates, such that the data on the repositioned concentration vs time curve correspond to exactly the same point on the timeline as their production. A vison sensor is developed to measure the sweating rate with high accuracy at a frequency of more than 0.1 Hz. Off-body and on-body measurements of sweating rate and Na+ concentration are carried out, and concentration–rate correlations are constructed using both measured and repositioned concentration curves. The least squares and random forest methods are employed to fit the constructed correlations and evaluate the reliability of the proposed approach. The use of the repositioned concentration curve gives a constructed correlation that is much closer to the actual one. This study indicates the necessity to rearrange sensor-measured biomarker concentration vs time curves when correlations of concentration with sweating rate need to be constructed and proposes a practical point-by-point data repositioning strategy for doing so. The results presented here will benefit the study of sweat biomarkers with unclear correlations with sweating rate, as well as providing a basis for the development of more reliable sweat-based diagnostic methods.
format Article
id doaj-art-91dd2e8398fd42ea91c91ecbdfc6b69e
institution OA Journals
issn 2589-5540
language English
publishDate 2025-03-01
publisher AIP Publishing LLC
record_format Article
series Nanotechnology and Precision Engineering
spelling doaj-art-91dd2e8398fd42ea91c91ecbdfc6b69e2025-08-20T02:02:20ZengAIP Publishing LLCNanotechnology and Precision Engineering2589-55402025-03-0181013006013006-1010.1063/10.0028758An effective approach for correlating Na+ concentrations with sweating rates in wearable sweat sensing platformAnwei He0Xiaohe Wang1Liang Zhang2Haolong Zhang3Xingli Xu4Chenyang Yu5Yongquan Ma6Wei Wei7Pengfei Niu8State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, ChinaState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, ChinaState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, ChinaState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, ChinaState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, ChinaState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, ChinaState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, ChinaState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, ChinaState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, ChinaAccurately correlating the sweating rate and the concentration of biomarkers in sweat is essential in many sweat-based diagnostic applications. These two measurements are always done simultaneously in wearable sweat sensing platforms. However, concentration measurements of biomarkers are always delayed on the timeline compared with their production, whereas there is no such delay for sweating rate. Thus, a timeline mismatch exists between these two measurements. This means that the concentration vs rate correlation constructed on the basis of such measurements will deviate from the actual correlation. This study demonstrates the existence of this mismatch and explains its cause using sweat Na+ measurements. It also proposes an effective approach that applies a point-by-point compensation for the delay between Na+ measurements and the real-time sweating rates, such that the data on the repositioned concentration vs time curve correspond to exactly the same point on the timeline as their production. A vison sensor is developed to measure the sweating rate with high accuracy at a frequency of more than 0.1 Hz. Off-body and on-body measurements of sweating rate and Na+ concentration are carried out, and concentration–rate correlations are constructed using both measured and repositioned concentration curves. The least squares and random forest methods are employed to fit the constructed correlations and evaluate the reliability of the proposed approach. The use of the repositioned concentration curve gives a constructed correlation that is much closer to the actual one. This study indicates the necessity to rearrange sensor-measured biomarker concentration vs time curves when correlations of concentration with sweating rate need to be constructed and proposes a practical point-by-point data repositioning strategy for doing so. The results presented here will benefit the study of sweat biomarkers with unclear correlations with sweating rate, as well as providing a basis for the development of more reliable sweat-based diagnostic methods.http://dx.doi.org/10.1063/10.0028758
spellingShingle Anwei He
Xiaohe Wang
Liang Zhang
Haolong Zhang
Xingli Xu
Chenyang Yu
Yongquan Ma
Wei Wei
Pengfei Niu
An effective approach for correlating Na+ concentrations with sweating rates in wearable sweat sensing platform
Nanotechnology and Precision Engineering
title An effective approach for correlating Na+ concentrations with sweating rates in wearable sweat sensing platform
title_full An effective approach for correlating Na+ concentrations with sweating rates in wearable sweat sensing platform
title_fullStr An effective approach for correlating Na+ concentrations with sweating rates in wearable sweat sensing platform
title_full_unstemmed An effective approach for correlating Na+ concentrations with sweating rates in wearable sweat sensing platform
title_short An effective approach for correlating Na+ concentrations with sweating rates in wearable sweat sensing platform
title_sort effective approach for correlating na concentrations with sweating rates in wearable sweat sensing platform
url http://dx.doi.org/10.1063/10.0028758
work_keys_str_mv AT anweihe aneffectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT xiaohewang aneffectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT liangzhang aneffectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT haolongzhang aneffectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT xinglixu aneffectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT chenyangyu aneffectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT yongquanma aneffectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT weiwei aneffectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT pengfeiniu aneffectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT anweihe effectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT xiaohewang effectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT liangzhang effectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT haolongzhang effectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT xinglixu effectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT chenyangyu effectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT yongquanma effectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT weiwei effectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform
AT pengfeiniu effectiveapproachforcorrelatingnaconcentrationswithsweatingratesinwearablesweatsensingplatform