Variability of Antibiotic Concentration in Solutions for Intracameral Administration in Cataract Surgery

Purpose: to evaluate the variability of cefuroxime concentration for intracameral administration during preparation of ex tempore solutions under conditions of real clinical practice.Materials and methods. Two operating room nurses participated in the study, each prepared 20 samples of cefuroxime so...

Full description

Saved in:
Bibliographic Details
Main Authors: S. N. Svetozarskiy, G. S. Igonin, V. V. Starostenko, S. V. Shcherbakova, A. N. Andreev, I. G. Smetankin
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2024-10-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/2432
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849240878838710272
author S. N. Svetozarskiy
G. S. Igonin
V. V. Starostenko
S. V. Shcherbakova
A. N. Andreev
I. G. Smetankin
author_facet S. N. Svetozarskiy
G. S. Igonin
V. V. Starostenko
S. V. Shcherbakova
A. N. Andreev
I. G. Smetankin
author_sort S. N. Svetozarskiy
collection DOAJ
description Purpose: to evaluate the variability of cefuroxime concentration for intracameral administration during preparation of ex tempore solutions under conditions of real clinical practice.Materials and methods. Two operating room nurses participated in the study, each prepared 20 samples of cefuroxime solution for intracameral administration according to a uniform dilution protocol. The concentration of antibiotic in the solutions was measured by photocolorimetric method.Results. The experiment modelling the conditions of real clinical practice demonstrated a significant difference of cefuroxime concentrations in solutions prepared ex tempore. The mean antibiotic concentration in samples prepared by 2 nurses was 1.189 [1.075; 1.383] mg/ml and 1.019 [0.984; 1.10] mg/ml, respectively, p = 0.0002. The range of variation was 0.4 mg/ml, or 40.5 % of the minimum recorded value.Conclusion. High variability of cefuroxime concentration during ex tempore preparation may lead to a number of undesirable events. Unintentional overdosing causes the development of serous retinal detachment and anterior chamber toxic syndrome. Low antibiotic content can be considered as one of the reasons for the development of infectious complications caused by cefuroxime-sensitive bacterial strains. Improvement of approaches, substances and routes of administration of antimicrobial agents to improve the safety of cataract surgery in the conditions of changing structure and increasing resistance of ocular microbiota seems to be an urgent scientific task.
format Article
id doaj-art-9173ff05c7cd4dbc81774bb2e0eef222
institution Kabale University
issn 1816-5095
2500-0845
language Russian
publishDate 2024-10-01
publisher Ophthalmology Publishing Group
record_format Article
series Oftalʹmologiâ
spelling doaj-art-9173ff05c7cd4dbc81774bb2e0eef2222025-08-20T04:00:20ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452024-10-0121354054510.18008/1816-5095-2024-3-540-5451174Variability of Antibiotic Concentration in Solutions for Intracameral Administration in Cataract SurgeryS. N. Svetozarskiy0G. S. Igonin1V. V. Starostenko2S. V. Shcherbakova3A. N. Andreev4I. G. Smetankin5Volga District Medical Centre under the Federal Medical and Biological Agency of Russia; Privolzhsky Research Medical UniversityPrivolzhsky Research Medical UniversityNational Research Lobachevsky State University of Nizhny NovgorodVolga District Medical Centre under the Federal Medical and Biological Agency of RussiaVolga District Medical Centre under the Federal Medical and Biological Agency of RussiaPrivolzhsky Research Medical UniversityPurpose: to evaluate the variability of cefuroxime concentration for intracameral administration during preparation of ex tempore solutions under conditions of real clinical practice.Materials and methods. Two operating room nurses participated in the study, each prepared 20 samples of cefuroxime solution for intracameral administration according to a uniform dilution protocol. The concentration of antibiotic in the solutions was measured by photocolorimetric method.Results. The experiment modelling the conditions of real clinical practice demonstrated a significant difference of cefuroxime concentrations in solutions prepared ex tempore. The mean antibiotic concentration in samples prepared by 2 nurses was 1.189 [1.075; 1.383] mg/ml and 1.019 [0.984; 1.10] mg/ml, respectively, p = 0.0002. The range of variation was 0.4 mg/ml, or 40.5 % of the minimum recorded value.Conclusion. High variability of cefuroxime concentration during ex tempore preparation may lead to a number of undesirable events. Unintentional overdosing causes the development of serous retinal detachment and anterior chamber toxic syndrome. Low antibiotic content can be considered as one of the reasons for the development of infectious complications caused by cefuroxime-sensitive bacterial strains. Improvement of approaches, substances and routes of administration of antimicrobial agents to improve the safety of cataract surgery in the conditions of changing structure and increasing resistance of ocular microbiota seems to be an urgent scientific task.https://www.ophthalmojournal.com/opht/article/view/2432phacoemulsificationcefuroximeantibioticside effecttoxic reaction
spellingShingle S. N. Svetozarskiy
G. S. Igonin
V. V. Starostenko
S. V. Shcherbakova
A. N. Andreev
I. G. Smetankin
Variability of Antibiotic Concentration in Solutions for Intracameral Administration in Cataract Surgery
Oftalʹmologiâ
phacoemulsification
cefuroxime
antibiotic
side effect
toxic reaction
title Variability of Antibiotic Concentration in Solutions for Intracameral Administration in Cataract Surgery
title_full Variability of Antibiotic Concentration in Solutions for Intracameral Administration in Cataract Surgery
title_fullStr Variability of Antibiotic Concentration in Solutions for Intracameral Administration in Cataract Surgery
title_full_unstemmed Variability of Antibiotic Concentration in Solutions for Intracameral Administration in Cataract Surgery
title_short Variability of Antibiotic Concentration in Solutions for Intracameral Administration in Cataract Surgery
title_sort variability of antibiotic concentration in solutions for intracameral administration in cataract surgery
topic phacoemulsification
cefuroxime
antibiotic
side effect
toxic reaction
url https://www.ophthalmojournal.com/opht/article/view/2432
work_keys_str_mv AT snsvetozarskiy variabilityofantibioticconcentrationinsolutionsforintracameraladministrationincataractsurgery
AT gsigonin variabilityofantibioticconcentrationinsolutionsforintracameraladministrationincataractsurgery
AT vvstarostenko variabilityofantibioticconcentrationinsolutionsforintracameraladministrationincataractsurgery
AT svshcherbakova variabilityofantibioticconcentrationinsolutionsforintracameraladministrationincataractsurgery
AT anandreev variabilityofantibioticconcentrationinsolutionsforintracameraladministrationincataractsurgery
AT igsmetankin variabilityofantibioticconcentrationinsolutionsforintracameraladministrationincataractsurgery