Application of artificial muscle e-rubber for healthcare sensing: verification of measurement properties as a smart insole

Electroactive polymer (EAP) artificial muscles are gaining attention in robotic control technologies. Among them, the development of self-sensing actuators that integrate sensing mechanisms within artificial muscles is highly anticipated. This study aimed to evaluate the accuracy and precision of th...

Full description

Saved in:
Bibliographic Details
Main Authors: Hidemasa Yoneda, Takashi Yamaga, Takeshi Fujiwara, Yoko Komori, Masatoshi Shimada, Yuki Kato, Shintaro Oyama, Shingo Shimoda, Michiro Yamamoto, Hitoshi Hirata
Format: Article
Language:English
Published: Frontiers Media S.A. 2025-08-01
Series:Frontiers in Bioengineering and Biotechnology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fbioe.2025.1639630/full
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849231579487928320
author Hidemasa Yoneda
Hidemasa Yoneda
Takashi Yamaga
Takeshi Fujiwara
Yoko Komori
Masatoshi Shimada
Yuki Kato
Shintaro Oyama
Shingo Shimoda
Michiro Yamamoto
Hitoshi Hirata
author_facet Hidemasa Yoneda
Hidemasa Yoneda
Takashi Yamaga
Takeshi Fujiwara
Yoko Komori
Masatoshi Shimada
Yuki Kato
Shintaro Oyama
Shingo Shimoda
Michiro Yamamoto
Hitoshi Hirata
author_sort Hidemasa Yoneda
collection DOAJ
description Electroactive polymer (EAP) artificial muscles are gaining attention in robotic control technologies. Among them, the development of self-sensing actuators that integrate sensing mechanisms within artificial muscles is highly anticipated. This study aimed to evaluate the accuracy and precision of the sensing capabilities of the e-Rubber (eR), an artificial muscle developed by Toyoda Gosei Co., Ltd., and to investigate its potential for healthcare sensing applications such as smart insoles. The objective was to transform the eR into a thin capacitor and estimate the applied load by sensing minute changes in the capacitance. The changes in the EAP dielectric constant, electrode area, and inter-electrode distance, all of which define the capacitance, are non-linear functions. The relationship with the external force also exhibits nonlinearity. To address this issue, we experimentally plotted the load and capacitance changes and derived a regression equation. We evaluated the sensing characteristics of both a stand-alone sensor and a sensor embedded in a smart insole, followed by a precision verification of the load estimation using the derived regression equation. Load–capacitance changes were measured up to 400 N at three conditions: 23 °C and 50% humidity, 40 °C and 50% humidity, and 40 °C and 80% humidity. For the standalone sensor, the coefficient of variation was less than 1.25% and the confidence interval was 0.25%, indicating high precision. However, for the sensor embedded within the insole housing, the coefficient of variation increased to less than 8%, and the confidence interval was 1.5%, likely owing to the influence of gaps within the insole structure. Regarding the load estimation equation, a 5th-order polynomial approximation (R2 >0.999) demonstrated the best fit, indicating that it is sufficiently accurate for healthcare sensing applications. Although capacitance-based sensors are increasingly being used in biomedical monitoring for pressure and load measurements owing to their durability and high sensitivity, their primary challenge lies in the nonlinearity of the sensing results. Although this challenge also exists for capacitance sensors utilizing artificial muscles, our study shows that developing a regression equation based on the experimental relationship between the load and capacitance changes can yield sufficient precision for practical healthcare applications.
format Article
id doaj-art-9113c067d74f45b98e1aa42d07adfc6d
institution Kabale University
issn 2296-4185
language English
publishDate 2025-08-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Bioengineering and Biotechnology
spelling doaj-art-9113c067d74f45b98e1aa42d07adfc6d2025-08-21T05:27:14ZengFrontiers Media S.A.Frontiers in Bioengineering and Biotechnology2296-41852025-08-011310.3389/fbioe.2025.16396301639630Application of artificial muscle e-rubber for healthcare sensing: verification of measurement properties as a smart insoleHidemasa Yoneda0Hidemasa Yoneda1Takashi Yamaga2Takeshi Fujiwara3Yoko Komori4Masatoshi Shimada5Yuki Kato6Shintaro Oyama7Shingo Shimoda8Michiro Yamamoto9Hitoshi Hirata10Human Enhancement and Hand Surgery, Nagoya University, Nagoya, JapanOrthopedic Surgery, Aichi Medical University, Nagakute, JapanOrthopedic Surgery, Tsushima City Hospital, Tsushima, JapanNew Value Business, Toyoda Gosei Co., Ltd., Ama, JapanNew Value Business, Toyoda Gosei Co., Ltd., Ama, JapanNew Value Business, Toyoda Gosei Co., Ltd., Ama, JapanOrthopedic Surgery, Chunichi Hospital, Nagoya, JapanGraduate School of Medicine, Nagoya University, Nagoya, JapanGraduate School of Medicine, Nagoya University, Nagoya, JapanHuman Enhancement and Hand Surgery, Nagoya University, Nagoya, JapanGraduate School of Medicine, Nagoya University, Nagoya, JapanElectroactive polymer (EAP) artificial muscles are gaining attention in robotic control technologies. Among them, the development of self-sensing actuators that integrate sensing mechanisms within artificial muscles is highly anticipated. This study aimed to evaluate the accuracy and precision of the sensing capabilities of the e-Rubber (eR), an artificial muscle developed by Toyoda Gosei Co., Ltd., and to investigate its potential for healthcare sensing applications such as smart insoles. The objective was to transform the eR into a thin capacitor and estimate the applied load by sensing minute changes in the capacitance. The changes in the EAP dielectric constant, electrode area, and inter-electrode distance, all of which define the capacitance, are non-linear functions. The relationship with the external force also exhibits nonlinearity. To address this issue, we experimentally plotted the load and capacitance changes and derived a regression equation. We evaluated the sensing characteristics of both a stand-alone sensor and a sensor embedded in a smart insole, followed by a precision verification of the load estimation using the derived regression equation. Load–capacitance changes were measured up to 400 N at three conditions: 23 °C and 50% humidity, 40 °C and 50% humidity, and 40 °C and 80% humidity. For the standalone sensor, the coefficient of variation was less than 1.25% and the confidence interval was 0.25%, indicating high precision. However, for the sensor embedded within the insole housing, the coefficient of variation increased to less than 8%, and the confidence interval was 1.5%, likely owing to the influence of gaps within the insole structure. Regarding the load estimation equation, a 5th-order polynomial approximation (R2 >0.999) demonstrated the best fit, indicating that it is sufficiently accurate for healthcare sensing applications. Although capacitance-based sensors are increasingly being used in biomedical monitoring for pressure and load measurements owing to their durability and high sensitivity, their primary challenge lies in the nonlinearity of the sensing results. Although this challenge also exists for capacitance sensors utilizing artificial muscles, our study shows that developing a regression equation based on the experimental relationship between the load and capacitance changes can yield sufficient precision for practical healthcare applications.https://www.frontiersin.org/articles/10.3389/fbioe.2025.1639630/fulle-rubberartificial musclecapacitance sensordielectric elastomersmart insolesensing for healthcare
spellingShingle Hidemasa Yoneda
Hidemasa Yoneda
Takashi Yamaga
Takeshi Fujiwara
Yoko Komori
Masatoshi Shimada
Yuki Kato
Shintaro Oyama
Shingo Shimoda
Michiro Yamamoto
Hitoshi Hirata
Application of artificial muscle e-rubber for healthcare sensing: verification of measurement properties as a smart insole
Frontiers in Bioengineering and Biotechnology
e-rubber
artificial muscle
capacitance sensor
dielectric elastomer
smart insole
sensing for healthcare
title Application of artificial muscle e-rubber for healthcare sensing: verification of measurement properties as a smart insole
title_full Application of artificial muscle e-rubber for healthcare sensing: verification of measurement properties as a smart insole
title_fullStr Application of artificial muscle e-rubber for healthcare sensing: verification of measurement properties as a smart insole
title_full_unstemmed Application of artificial muscle e-rubber for healthcare sensing: verification of measurement properties as a smart insole
title_short Application of artificial muscle e-rubber for healthcare sensing: verification of measurement properties as a smart insole
title_sort application of artificial muscle e rubber for healthcare sensing verification of measurement properties as a smart insole
topic e-rubber
artificial muscle
capacitance sensor
dielectric elastomer
smart insole
sensing for healthcare
url https://www.frontiersin.org/articles/10.3389/fbioe.2025.1639630/full
work_keys_str_mv AT hidemasayoneda applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT hidemasayoneda applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT takashiyamaga applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT takeshifujiwara applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT yokokomori applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT masatoshishimada applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT yukikato applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT shintarooyama applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT shingoshimoda applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT michiroyamamoto applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole
AT hitoshihirata applicationofartificialmuscleerubberforhealthcaresensingverificationofmeasurementpropertiesasasmartinsole