ANALYSIS OF HYPOTENSIVE EFFECT OF EX-PRESS DRAINAGE DEVICE FOR REFRACTORY GLAUCOMA

Purpose: to analyze the effectiveness of Ex-Press drainage device implantation  for refractory glaucoma  of different origin for 3 years.Patients and methods: The study  consisted of 82 patients (86  eyes)  with refractory  glaucoma  aged  26–86 years  (67.37±0.53). Pre-operative  IOP level averaged...

Full description

Saved in:
Bibliographic Details
Main Authors: M. M. Bikbov, I. I. Khusnitdinov
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2017-07-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/376
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849687530399596544
author M. M. Bikbov
I. I. Khusnitdinov
author_facet M. M. Bikbov
I. I. Khusnitdinov
author_sort M. M. Bikbov
collection DOAJ
description Purpose: to analyze the effectiveness of Ex-Press drainage device implantation  for refractory glaucoma  of different origin for 3 years.Patients and methods: The study  consisted of 82 patients (86  eyes)  with refractory  glaucoma  aged  26–86 years  (67.37±0.53). Pre-operative  IOP level averaged 37.8±1.04  mm  Hg.  Ex-Press  drainage device  implantation  was  rated according to  the  following criteria: IOP, time course of visual functions,  the need  for additional drug therapy  and reoperation, the presence of intraoperative and postoperative complications. Examination of the  patients was carried out from 1 to 8 days after  the  surgery and within 1, 3, 6, 12, 24 and 36 months.Results: According to our research results relative hypotensive effect equaled  74.4% (64/86) within a year after the  surgery; 67.4% (58/86) — within 2 years;  65.1% (56/86) — after  3 years  of follow-up period.  The maximum decrease in IOP by 61.6% was observed immediately after  the  surgery. There  was no effect of surgical  treatment within3 years  in 34.9% (30/86). Complications  were  observed  in 23.2% (20/86) of cases: choroidal  detachment — 12.8% (11/86),  hyphema  — 3.5% (3/86), eruption  and  dislocation  — 3.5% (3 / 86), delayed  expulsive hemorrhage — 2.3% (2/86), cyst of filtering bleb — 1.2% (1/86).Conclusion. Fistulizing operations with implantation  of Ex-Press drainage device for refractory glaucoma  provide normalization  of IOP in 65.1% of cases (including 15.1% on the background of additional drug therapy)  at follow-up period up to 3 years.
format Article
id doaj-art-905a870eecc046e8a4201d772893ec5b
institution DOAJ
issn 1816-5095
2500-0845
language Russian
publishDate 2017-07-01
publisher Ophthalmology Publishing Group
record_format Article
series Oftalʹmologiâ
spelling doaj-art-905a870eecc046e8a4201d772893ec5b2025-08-20T03:22:18ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452017-07-0114214114610.18008/1816-5095-2017-2-141-146340ANALYSIS OF HYPOTENSIVE EFFECT OF EX-PRESS DRAINAGE DEVICE FOR REFRACTORY GLAUCOMAM. M. Bikbov0I. I. Khusnitdinov1Ufa Eye Research Institute of Academy of Sciences of the Republic of BashkortostanUfa Eye Research Institute of Academy of Sciences of the Republic of BashkortostanPurpose: to analyze the effectiveness of Ex-Press drainage device implantation  for refractory glaucoma  of different origin for 3 years.Patients and methods: The study  consisted of 82 patients (86  eyes)  with refractory  glaucoma  aged  26–86 years  (67.37±0.53). Pre-operative  IOP level averaged 37.8±1.04  mm  Hg.  Ex-Press  drainage device  implantation  was  rated according to  the  following criteria: IOP, time course of visual functions,  the need  for additional drug therapy  and reoperation, the presence of intraoperative and postoperative complications. Examination of the  patients was carried out from 1 to 8 days after  the  surgery and within 1, 3, 6, 12, 24 and 36 months.Results: According to our research results relative hypotensive effect equaled  74.4% (64/86) within a year after the  surgery; 67.4% (58/86) — within 2 years;  65.1% (56/86) — after  3 years  of follow-up period.  The maximum decrease in IOP by 61.6% was observed immediately after  the  surgery. There  was no effect of surgical  treatment within3 years  in 34.9% (30/86). Complications  were  observed  in 23.2% (20/86) of cases: choroidal  detachment — 12.8% (11/86),  hyphema  — 3.5% (3/86), eruption  and  dislocation  — 3.5% (3 / 86), delayed  expulsive hemorrhage — 2.3% (2/86), cyst of filtering bleb — 1.2% (1/86).Conclusion. Fistulizing operations with implantation  of Ex-Press drainage device for refractory glaucoma  provide normalization  of IOP in 65.1% of cases (including 15.1% on the background of additional drug therapy)  at follow-up period up to 3 years.https://www.ophthalmojournal.com/opht/article/view/376refractory glaucomadrainage glaucoma surgeryex-press drainage devicelong-term results
spellingShingle M. M. Bikbov
I. I. Khusnitdinov
ANALYSIS OF HYPOTENSIVE EFFECT OF EX-PRESS DRAINAGE DEVICE FOR REFRACTORY GLAUCOMA
Oftalʹmologiâ
refractory glaucoma
drainage glaucoma surgery
ex-press drainage device
long-term results
title ANALYSIS OF HYPOTENSIVE EFFECT OF EX-PRESS DRAINAGE DEVICE FOR REFRACTORY GLAUCOMA
title_full ANALYSIS OF HYPOTENSIVE EFFECT OF EX-PRESS DRAINAGE DEVICE FOR REFRACTORY GLAUCOMA
title_fullStr ANALYSIS OF HYPOTENSIVE EFFECT OF EX-PRESS DRAINAGE DEVICE FOR REFRACTORY GLAUCOMA
title_full_unstemmed ANALYSIS OF HYPOTENSIVE EFFECT OF EX-PRESS DRAINAGE DEVICE FOR REFRACTORY GLAUCOMA
title_short ANALYSIS OF HYPOTENSIVE EFFECT OF EX-PRESS DRAINAGE DEVICE FOR REFRACTORY GLAUCOMA
title_sort analysis of hypotensive effect of ex press drainage device for refractory glaucoma
topic refractory glaucoma
drainage glaucoma surgery
ex-press drainage device
long-term results
url https://www.ophthalmojournal.com/opht/article/view/376
work_keys_str_mv AT mmbikbov analysisofhypotensiveeffectofexpressdrainagedeviceforrefractoryglaucoma
AT iikhusnitdinov analysisofhypotensiveeffectofexpressdrainagedeviceforrefractoryglaucoma