Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

An accurate and precise HPLC method was developed for the determination of lisinopril. Separation of the drug was achieved on a reverse phase C8 column using a mobile phase consisting of phosphate buffer and methanol in the ratio of 35:65v/v. The flow rate was 0.8 mL/min and the detection wavelength...

Full description

Saved in:
Bibliographic Details
Main Authors: V. Bhaskara Raju, A. Lakshmana Rao
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:E-Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2012/292754
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:An accurate and precise HPLC method was developed for the determination of lisinopril. Separation of the drug was achieved on a reverse phase C8 column using a mobile phase consisting of phosphate buffer and methanol in the ratio of 35:65v/v. The flow rate was 0.8 mL/min and the detection wavelength was 215 nm. The linearity was observed in the range of 20-60 μ g/mL with a correlation coefficient of 0.9992. The proposed method was validated for its linearity, accuracy, precision and robustness. This method can be employed for routine quality control analysis of lisinopril in tablet dosage forms.
ISSN:0973-4945
2090-9810