An Evaluation Method of Feeder Automation in Active Distribution Network

Wide access of distributed generation introduces a new challenge to the traditional feeder automation ( FA) evaluation method. Given this background,an evaluation method of the feeder automation ( FA) for active distribution network is presented. Firstly,the load states during the fault location,iso...

Full description

Saved in:
Bibliographic Details
Main Authors: QIU Dong, WANG Xiu-ru, ZHANG Ke, LIU Gang, HAN Shao-hua, WANG Ke-long
Format: Article
Language:zho
Published: Harbin University of Science and Technology Publications 2021-04-01
Series:Journal of Harbin University of Science and Technology
Subjects:
Online Access:https://hlgxb.hrbust.edu.cn/#/digest?ArticleID=1945
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849392428637749248
author QIU Dong
WANG Xiu-ru
ZHANG Ke
LIU Gang
HAN Shao-hua
WANG Ke-long
author_facet QIU Dong
WANG Xiu-ru
ZHANG Ke
LIU Gang
HAN Shao-hua
WANG Ke-long
author_sort QIU Dong
collection DOAJ
description Wide access of distributed generation introduces a new challenge to the traditional feeder automation ( FA) evaluation method. Given this background,an evaluation method of the feeder automation ( FA) for active distribution network is presented. Firstly,the load states during the fault location,isolation and restoration process are elaborately defined and the interference factors affecting FA are systematically researched. Secondly,the FA action evaluation method is proposed,including seven evaluation indexes from two aspects of action process and action result,respectively. Subsequently,the comprehensive evaluation method of the action effectiveness for the FA in the active distribution network is improved based on the failure-free evaluation test method. Finally,a FA system with double loop network is employed to demonstrate the effectiveness of the proposed evaluation method.
format Article
id doaj-art-8d93ca2562024a90aa68ccb73d79c66f
institution Kabale University
issn 1007-2683
language zho
publishDate 2021-04-01
publisher Harbin University of Science and Technology Publications
record_format Article
series Journal of Harbin University of Science and Technology
spelling doaj-art-8d93ca2562024a90aa68ccb73d79c66f2025-08-20T03:40:47ZzhoHarbin University of Science and Technology PublicationsJournal of Harbin University of Science and Technology1007-26832021-04-012602839010.15938/j.jhust.2021.02.011An Evaluation Method of Feeder Automation in Active Distribution NetworkQIU Dong0WANG Xiu-ru1ZHANG Ke2LIU Gang3HAN Shao-hua4WANG Ke-long5State Grid Jiangsu Electric Power Company Suqian Power Supply Company,Suqian 215000,ChinaState Grid Jiangsu Electric Power Company Suqian Power Supply Company,Suqian 215000,ChinaState Grid Jiangsu Electric Power Company Suqian Power Supply Company,Suqian 215000,ChinaState Grid Jiangsu Electric Power Company Suqian Power Supply Company,Suqian 215000,ChinaState Grid Jiangsu Electric Power Company Suqian Power Supply Company,Suqian 215000,ChinaShanghai Wiscom Sunest Electricity Power Technology Co. ,Ltd,Shanghai 200233,ChinaWide access of distributed generation introduces a new challenge to the traditional feeder automation ( FA) evaluation method. Given this background,an evaluation method of the feeder automation ( FA) for active distribution network is presented. Firstly,the load states during the fault location,isolation and restoration process are elaborately defined and the interference factors affecting FA are systematically researched. Secondly,the FA action evaluation method is proposed,including seven evaluation indexes from two aspects of action process and action result,respectively. Subsequently,the comprehensive evaluation method of the action effectiveness for the FA in the active distribution network is improved based on the failure-free evaluation test method. Finally,a FA system with double loop network is employed to demonstrate the effectiveness of the proposed evaluation method.https://hlgxb.hrbust.edu.cn/#/digest?ArticleID=1945feeder automation( fa)action effectivenessevaluation indexevaluation methodtesting method
spellingShingle QIU Dong
WANG Xiu-ru
ZHANG Ke
LIU Gang
HAN Shao-hua
WANG Ke-long
An Evaluation Method of Feeder Automation in Active Distribution Network
Journal of Harbin University of Science and Technology
feeder automation( fa)
action effectiveness
evaluation index
evaluation method
testing method
title An Evaluation Method of Feeder Automation in Active Distribution Network
title_full An Evaluation Method of Feeder Automation in Active Distribution Network
title_fullStr An Evaluation Method of Feeder Automation in Active Distribution Network
title_full_unstemmed An Evaluation Method of Feeder Automation in Active Distribution Network
title_short An Evaluation Method of Feeder Automation in Active Distribution Network
title_sort evaluation method of feeder automation in active distribution network
topic feeder automation( fa)
action effectiveness
evaluation index
evaluation method
testing method
url https://hlgxb.hrbust.edu.cn/#/digest?ArticleID=1945
work_keys_str_mv AT qiudong anevaluationmethodoffeederautomationinactivedistributionnetwork
AT wangxiuru anevaluationmethodoffeederautomationinactivedistributionnetwork
AT zhangke anevaluationmethodoffeederautomationinactivedistributionnetwork
AT liugang anevaluationmethodoffeederautomationinactivedistributionnetwork
AT hanshaohua anevaluationmethodoffeederautomationinactivedistributionnetwork
AT wangkelong anevaluationmethodoffeederautomationinactivedistributionnetwork
AT qiudong evaluationmethodoffeederautomationinactivedistributionnetwork
AT wangxiuru evaluationmethodoffeederautomationinactivedistributionnetwork
AT zhangke evaluationmethodoffeederautomationinactivedistributionnetwork
AT liugang evaluationmethodoffeederautomationinactivedistributionnetwork
AT hanshaohua evaluationmethodoffeederautomationinactivedistributionnetwork
AT wangkelong evaluationmethodoffeederautomationinactivedistributionnetwork