INVESTIGATING POINTS-OF-GENERATION POWER LOSSES ON THE NIGERIAN NATIONAL GRID FOLLOWING UNBUNDLING OF THE ELECTRIC UTILITY INDUSTRY

Aside from the domino effects of being radial in structure, the Nigerian national electric grid is currently suffering from deteriorated infrastructures and unpredictable fuel supply for power generation. Massive introduction of green energy-based microgrid alternatives has been proposed as a major...

Full description

Saved in:
Bibliographic Details
Main Authors: AJEWOLE TITUS OLUWASUJI, OLABODE OLAKUNLE ELIJAH, OKAKWU IGNATIUS KEMA, EGBEDINNI OLAKUNLE FEMI
Format: Article
Language:English
Published: Alma Mater Publishing House "Vasile Alecsandri" University of Bacau 2021-06-01
Series:Journal of Engineering Studies and Research
Subjects:
Online Access:https://jesr.ub.ro/index.php/1/article/view/259
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823858352545857536
author AJEWOLE TITUS OLUWASUJI
OLABODE OLAKUNLE ELIJAH
OKAKWU IGNATIUS KEMA
EGBEDINNI OLAKUNLE FEMI
author_facet AJEWOLE TITUS OLUWASUJI
OLABODE OLAKUNLE ELIJAH
OKAKWU IGNATIUS KEMA
EGBEDINNI OLAKUNLE FEMI
author_sort AJEWOLE TITUS OLUWASUJI
collection DOAJ
description Aside from the domino effects of being radial in structure, the Nigerian national electric grid is currently suffering from deteriorated infrastructures and unpredictable fuel supply for power generation. Massive introduction of green energy-based microgrid alternatives has been proposed as a major means of resolving the challenges. Such paradigm shift needs to be substantiated within the context of the present situation of the grid, for the consumption of policy makers and implementers, hence; the performance of the generation sub-system of the grid in the post-deregulation era is evaluated in this study. Two-year numerical data on the operational capacities of the twenty-nine power plants that are currently connected to the grid are employed to profile the behaviours of the plants over the period. Yearly averages of the three operational capacities of each plant are estimated, and by comparing the respective capacities, generation losses are computed for each of the plants. With 5,063.8 MW yearly average generation capacity in the year 2018, a loss of 61.02 % was experienced on the sub-system; while the generation loss was 61.55 % in the year 2019 that has yearly average generation capacity of 5,062.5 MW. For the two years combined, the average generation capacity is 5,063.2 MW at 61.36 % power loss. These estimations reveal that the pre-deregulation loss profile of the generation sub-system has not been curtailed despite the unbundling of the electric power industry. Generation loss has rather persisted and keeps taking a heavy toll on the electric utility market of the country. Significant deployment of renewable electricity microgrid is therefore required to provide enduring solution.
format Article
id doaj-art-8d8243bf6dd94c12b7c903cc6686622b
institution Kabale University
issn 2068-7559
2344-4932
language English
publishDate 2021-06-01
publisher Alma Mater Publishing House "Vasile Alecsandri" University of Bacau
record_format Article
series Journal of Engineering Studies and Research
spelling doaj-art-8d8243bf6dd94c12b7c903cc6686622b2025-02-11T11:40:18ZengAlma Mater Publishing House "Vasile Alecsandri" University of BacauJournal of Engineering Studies and Research2068-75592344-49322021-06-0127110.29081/jesr.v27i1.259INVESTIGATING POINTS-OF-GENERATION POWER LOSSES ON THE NIGERIAN NATIONAL GRID FOLLOWING UNBUNDLING OF THE ELECTRIC UTILITY INDUSTRYAJEWOLE TITUS OLUWASUJIOLABODE OLAKUNLE ELIJAHOKAKWU IGNATIUS KEMAEGBEDINNI OLAKUNLE FEMI Aside from the domino effects of being radial in structure, the Nigerian national electric grid is currently suffering from deteriorated infrastructures and unpredictable fuel supply for power generation. Massive introduction of green energy-based microgrid alternatives has been proposed as a major means of resolving the challenges. Such paradigm shift needs to be substantiated within the context of the present situation of the grid, for the consumption of policy makers and implementers, hence; the performance of the generation sub-system of the grid in the post-deregulation era is evaluated in this study. Two-year numerical data on the operational capacities of the twenty-nine power plants that are currently connected to the grid are employed to profile the behaviours of the plants over the period. Yearly averages of the three operational capacities of each plant are estimated, and by comparing the respective capacities, generation losses are computed for each of the plants. With 5,063.8 MW yearly average generation capacity in the year 2018, a loss of 61.02 % was experienced on the sub-system; while the generation loss was 61.55 % in the year 2019 that has yearly average generation capacity of 5,062.5 MW. For the two years combined, the average generation capacity is 5,063.2 MW at 61.36 % power loss. These estimations reveal that the pre-deregulation loss profile of the generation sub-system has not been curtailed despite the unbundling of the electric power industry. Generation loss has rather persisted and keeps taking a heavy toll on the electric utility market of the country. Significant deployment of renewable electricity microgrid is therefore required to provide enduring solution. https://jesr.ub.ro/index.php/1/article/view/259power plants; generation loss; loss profile, green energy, renewable electricity
spellingShingle AJEWOLE TITUS OLUWASUJI
OLABODE OLAKUNLE ELIJAH
OKAKWU IGNATIUS KEMA
EGBEDINNI OLAKUNLE FEMI
INVESTIGATING POINTS-OF-GENERATION POWER LOSSES ON THE NIGERIAN NATIONAL GRID FOLLOWING UNBUNDLING OF THE ELECTRIC UTILITY INDUSTRY
Journal of Engineering Studies and Research
power plants; generation loss; loss profile, green energy, renewable electricity
title INVESTIGATING POINTS-OF-GENERATION POWER LOSSES ON THE NIGERIAN NATIONAL GRID FOLLOWING UNBUNDLING OF THE ELECTRIC UTILITY INDUSTRY
title_full INVESTIGATING POINTS-OF-GENERATION POWER LOSSES ON THE NIGERIAN NATIONAL GRID FOLLOWING UNBUNDLING OF THE ELECTRIC UTILITY INDUSTRY
title_fullStr INVESTIGATING POINTS-OF-GENERATION POWER LOSSES ON THE NIGERIAN NATIONAL GRID FOLLOWING UNBUNDLING OF THE ELECTRIC UTILITY INDUSTRY
title_full_unstemmed INVESTIGATING POINTS-OF-GENERATION POWER LOSSES ON THE NIGERIAN NATIONAL GRID FOLLOWING UNBUNDLING OF THE ELECTRIC UTILITY INDUSTRY
title_short INVESTIGATING POINTS-OF-GENERATION POWER LOSSES ON THE NIGERIAN NATIONAL GRID FOLLOWING UNBUNDLING OF THE ELECTRIC UTILITY INDUSTRY
title_sort investigating points of generation power losses on the nigerian national grid following unbundling of the electric utility industry
topic power plants; generation loss; loss profile, green energy, renewable electricity
url https://jesr.ub.ro/index.php/1/article/view/259
work_keys_str_mv AT ajewoletitusoluwasuji investigatingpointsofgenerationpowerlossesonthenigeriannationalgridfollowingunbundlingoftheelectricutilityindustry
AT olabodeolakunleelijah investigatingpointsofgenerationpowerlossesonthenigeriannationalgridfollowingunbundlingoftheelectricutilityindustry
AT okakwuignatiuskema investigatingpointsofgenerationpowerlossesonthenigeriannationalgridfollowingunbundlingoftheelectricutilityindustry
AT egbedinniolakunlefemi investigatingpointsofgenerationpowerlossesonthenigeriannationalgridfollowingunbundlingoftheelectricutilityindustry