Determination of the MEC90 of Oxycodone for Preventing Perioperative Shivering in Pregnant Patients Undergoing Caesarean Delivery with Neuraxial Anaesthesia: A Biased-Coin up-and-Down Sequential Allocation Trial

Xinlei Lu,1,* Kaiyu Chen,1,2,* Ye Xuan,1,2 Mengting Shen,1,2 Weiping Lei,1 Yaqin Huang,1 Jianliang Sun1 1Department of Anaesthesiology, Affiliated Hangzhou First People’s Hospital, School of Medicine, Westlake University, Hangzhou, People’s Republic of China; 2The Fourth School of Cl...

Full description

Saved in:
Bibliographic Details
Main Authors: Lu X, Chen K, Xuan Y, Shen M, Lei W, Huang Y, Sun J
Format: Article
Language:English
Published: Dove Medical Press 2025-02-01
Series:Drug Design, Development and Therapy
Subjects:
Online Access:https://www.dovepress.com/determination-of-the-mec90-of-oxycodone-for-preventing-perioperative-s-peer-reviewed-fulltext-article-DDDT
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823857990457884672
author Lu X
Chen K
Xuan Y
Shen M
Lei W
Huang Y
Sun J
author_facet Lu X
Chen K
Xuan Y
Shen M
Lei W
Huang Y
Sun J
author_sort Lu X
collection DOAJ
description Xinlei Lu,1,* Kaiyu Chen,1,2,* Ye Xuan,1,2 Mengting Shen,1,2 Weiping Lei,1 Yaqin Huang,1 Jianliang Sun1 1Department of Anaesthesiology, Affiliated Hangzhou First People’s Hospital, School of Medicine, Westlake University, Hangzhou, People’s Republic of China; 2The Fourth School of Clinical Medicine, Zhejiang Chinese Medical University, Hangzhou, People’s Republic of China*These authors contributed equally to this workCorrespondence: Jianliang Sun, Department of Anaesthesiology, Affiliated Hangzhou First People’s Hospital, School of Medicine, Westlake University, Hangzhou, People’s Republic of China, Email jxmzsjl@163.comBackground: Perioperative shivering is a common adverse reaction to neuraxial anaesthesia. Intravenous oxycodone can be used to prevent shivering. However, few trials have been conducted on the use of oxycodone to prevent shivering, and the optimal dose is unknown. This study aimed to determine the optimal dose (90% minimum effective concentration [MEC90]) of intraoperative oxycodone to prevent shivering during caesarean section.Methods: This study was designed by the biased-coin up-and-down method. We recruited pregnant women who underwent caesarean section under combined spinal–epidural anaesthesia. Oxycodone was administered intravenously after the delivery of the foetus. The initial dose was 80 μg/kg, and subsequent dose adjustments were determined by up-and-down sequential allocation using a biased-coin design based on the response of the previous patient. The primary outcome was the MEC90 for oxycodone injection based on the success or failure of the shivering-preventing dose.Results: Fifty patients were enrolled in the study. The oxycodone dose ranged from 80 to 95 μg/kg. The estimated MEC90 (95% confidence interval [CI]) for preventing shivering was 88.1 μg/kg (81.5– 92.5 μg/kg). The patient’s postoperative temperature was 36.5 ± 0.2 °C. The incidence of intraoperative traction pain was 12%. The 5-min and 30-min Ramsay sedation scores were 3 (3– 4) and 3 (3– 3), respectively. The 2-h and 6-h postoperative VAS scores were 3 (2– 3) and 4 (3– 5), respectively. The patient’s anaesthesia satisfaction score was 5 (4– 5). The incidence of respiratory depression was 2%, and the incidence of nausea and vomiting was 16%.Conclusion: The MEC90 of intraoperative intravenous oxycodone for the prevention of shivering in women undergoing caesarean section with neuraxial anaesthesia was 88.1 μg/kg (95% CI: 81.5– 92.5 μg/kg).Keywords: MEC90, oxycodone, perioperative shivering, caesarean delivery, neuraxial anaesthesia
format Article
id doaj-art-8d30009c3756468ca2c1e2ac381a5359
institution Kabale University
issn 1177-8881
language English
publishDate 2025-02-01
publisher Dove Medical Press
record_format Article
series Drug Design, Development and Therapy
spelling doaj-art-8d30009c3756468ca2c1e2ac381a53592025-02-11T17:30:55ZengDove Medical PressDrug Design, Development and Therapy1177-88812025-02-01Volume 19945954100083Determination of the MEC90 of Oxycodone for Preventing Perioperative Shivering in Pregnant Patients Undergoing Caesarean Delivery with Neuraxial Anaesthesia: A Biased-Coin up-and-Down Sequential Allocation TrialLu XChen KXuan YShen MLei WHuang YSun JXinlei Lu,1,* Kaiyu Chen,1,2,* Ye Xuan,1,2 Mengting Shen,1,2 Weiping Lei,1 Yaqin Huang,1 Jianliang Sun1 1Department of Anaesthesiology, Affiliated Hangzhou First People’s Hospital, School of Medicine, Westlake University, Hangzhou, People’s Republic of China; 2The Fourth School of Clinical Medicine, Zhejiang Chinese Medical University, Hangzhou, People’s Republic of China*These authors contributed equally to this workCorrespondence: Jianliang Sun, Department of Anaesthesiology, Affiliated Hangzhou First People’s Hospital, School of Medicine, Westlake University, Hangzhou, People’s Republic of China, Email jxmzsjl@163.comBackground: Perioperative shivering is a common adverse reaction to neuraxial anaesthesia. Intravenous oxycodone can be used to prevent shivering. However, few trials have been conducted on the use of oxycodone to prevent shivering, and the optimal dose is unknown. This study aimed to determine the optimal dose (90% minimum effective concentration [MEC90]) of intraoperative oxycodone to prevent shivering during caesarean section.Methods: This study was designed by the biased-coin up-and-down method. We recruited pregnant women who underwent caesarean section under combined spinal–epidural anaesthesia. Oxycodone was administered intravenously after the delivery of the foetus. The initial dose was 80 μg/kg, and subsequent dose adjustments were determined by up-and-down sequential allocation using a biased-coin design based on the response of the previous patient. The primary outcome was the MEC90 for oxycodone injection based on the success or failure of the shivering-preventing dose.Results: Fifty patients were enrolled in the study. The oxycodone dose ranged from 80 to 95 μg/kg. The estimated MEC90 (95% confidence interval [CI]) for preventing shivering was 88.1 μg/kg (81.5– 92.5 μg/kg). The patient’s postoperative temperature was 36.5 ± 0.2 °C. The incidence of intraoperative traction pain was 12%. The 5-min and 30-min Ramsay sedation scores were 3 (3– 4) and 3 (3– 3), respectively. The 2-h and 6-h postoperative VAS scores were 3 (2– 3) and 4 (3– 5), respectively. The patient’s anaesthesia satisfaction score was 5 (4– 5). The incidence of respiratory depression was 2%, and the incidence of nausea and vomiting was 16%.Conclusion: The MEC90 of intraoperative intravenous oxycodone for the prevention of shivering in women undergoing caesarean section with neuraxial anaesthesia was 88.1 μg/kg (95% CI: 81.5– 92.5 μg/kg).Keywords: MEC90, oxycodone, perioperative shivering, caesarean delivery, neuraxial anaesthesiahttps://www.dovepress.com/determination-of-the-mec90-of-oxycodone-for-preventing-perioperative-s-peer-reviewed-fulltext-article-DDDTmec90oxycodoneperioperative shiveringcaesarean deliveryneuraxial anaesthesia
spellingShingle Lu X
Chen K
Xuan Y
Shen M
Lei W
Huang Y
Sun J
Determination of the MEC90 of Oxycodone for Preventing Perioperative Shivering in Pregnant Patients Undergoing Caesarean Delivery with Neuraxial Anaesthesia: A Biased-Coin up-and-Down Sequential Allocation Trial
Drug Design, Development and Therapy
mec90
oxycodone
perioperative shivering
caesarean delivery
neuraxial anaesthesia
title Determination of the MEC90 of Oxycodone for Preventing Perioperative Shivering in Pregnant Patients Undergoing Caesarean Delivery with Neuraxial Anaesthesia: A Biased-Coin up-and-Down Sequential Allocation Trial
title_full Determination of the MEC90 of Oxycodone for Preventing Perioperative Shivering in Pregnant Patients Undergoing Caesarean Delivery with Neuraxial Anaesthesia: A Biased-Coin up-and-Down Sequential Allocation Trial
title_fullStr Determination of the MEC90 of Oxycodone for Preventing Perioperative Shivering in Pregnant Patients Undergoing Caesarean Delivery with Neuraxial Anaesthesia: A Biased-Coin up-and-Down Sequential Allocation Trial
title_full_unstemmed Determination of the MEC90 of Oxycodone for Preventing Perioperative Shivering in Pregnant Patients Undergoing Caesarean Delivery with Neuraxial Anaesthesia: A Biased-Coin up-and-Down Sequential Allocation Trial
title_short Determination of the MEC90 of Oxycodone for Preventing Perioperative Shivering in Pregnant Patients Undergoing Caesarean Delivery with Neuraxial Anaesthesia: A Biased-Coin up-and-Down Sequential Allocation Trial
title_sort determination of the mec90 of oxycodone for preventing perioperative shivering in pregnant patients undergoing caesarean delivery with neuraxial anaesthesia a biased coin up and down sequential allocation trial
topic mec90
oxycodone
perioperative shivering
caesarean delivery
neuraxial anaesthesia
url https://www.dovepress.com/determination-of-the-mec90-of-oxycodone-for-preventing-perioperative-s-peer-reviewed-fulltext-article-DDDT
work_keys_str_mv AT lux determinationofthemec90ofoxycodoneforpreventingperioperativeshiveringinpregnantpatientsundergoingcaesareandeliverywithneuraxialanaesthesiaabiasedcoinupanddownsequentialallocationtrial
AT chenk determinationofthemec90ofoxycodoneforpreventingperioperativeshiveringinpregnantpatientsundergoingcaesareandeliverywithneuraxialanaesthesiaabiasedcoinupanddownsequentialallocationtrial
AT xuany determinationofthemec90ofoxycodoneforpreventingperioperativeshiveringinpregnantpatientsundergoingcaesareandeliverywithneuraxialanaesthesiaabiasedcoinupanddownsequentialallocationtrial
AT shenm determinationofthemec90ofoxycodoneforpreventingperioperativeshiveringinpregnantpatientsundergoingcaesareandeliverywithneuraxialanaesthesiaabiasedcoinupanddownsequentialallocationtrial
AT leiw determinationofthemec90ofoxycodoneforpreventingperioperativeshiveringinpregnantpatientsundergoingcaesareandeliverywithneuraxialanaesthesiaabiasedcoinupanddownsequentialallocationtrial
AT huangy determinationofthemec90ofoxycodoneforpreventingperioperativeshiveringinpregnantpatientsundergoingcaesareandeliverywithneuraxialanaesthesiaabiasedcoinupanddownsequentialallocationtrial
AT sunj determinationofthemec90ofoxycodoneforpreventingperioperativeshiveringinpregnantpatientsundergoingcaesareandeliverywithneuraxialanaesthesiaabiasedcoinupanddownsequentialallocationtrial