NONADIABATIC RECTIFICATION CONTACT DEVICES

On the basis of the developed method of heat rectification implying partial condensation of the vapor mixture rising along the height of the column and the resulting evaporation of condensate before it is mixed with the main stream of the flowing reflux the process of strengthening the ethanol-water...

Full description

Saved in:
Bibliographic Details
Main Authors: Voinov N.A., Zemtsov D.A., Zhukova O.P.
Format: Article
Language:English
Published: Kemerovo State University 2017-03-01
Series:Техника и технология пищевых производств
Subjects:
Online Access:http://fptt.ru/stories/archive/44/9.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850033803987255296
author Voinov N.A.
Zemtsov D.A.
Zhukova O.P.
author_facet Voinov N.A.
Zemtsov D.A.
Zhukova O.P.
author_sort Voinov N.A.
collection DOAJ
description On the basis of the developed method of heat rectification implying partial condensation of the vapor mixture rising along the height of the column and the resulting evaporation of condensate before it is mixed with the main stream of the flowing reflux the process of strengthening the ethanol-water mixture in the contact levels with high and low mass exchange is investigated and intensified. The process of nonadiabatic rectification was carried out on the contact steps, and then held in the columns with 24 contact stages. The intensive mass transfer was achieved using a vortex steps performed by tangential swirlers. Contact stages of low-mass exchange were made of horizontally installed profiled copper plates. The paper presents the technological parameters which change the flow regime of the rotating layer on vortex stage. The value of the hydraulic resistance coefficient of the device is also determined. The dependence for determining the effectiveness of the contact stage was estimated by Murphree. The efficiency depends on the stage of the vortex flow ratio, fluid bed height, Reynolds centrifugal rotating layer, and the slope of the equilibrium curve. In the study of the steps made of the plates it was revealed that the greatest contribution to the strengthening of the mixture isallowed by the processes of evaporation and condensation occurring on the upper plate of the unit. The dependence was revealed for assessing the effectiveness of the contact stage of the plates, which depends on the specific expenditure reflux and steam mixture, condensation and evaporation surfaces, and steam radial velocity between the plates. To intensify the separation process the effected reflux rotation plates were disposed on the lower stage of each column by installing them on the motor shaft. It is shown that rotation of the liquid intensifies the mass transfer in the liquid and vapor phases. It is established, that the increasing number of revolutions of the plate and the concentration of volatile component in the mixture increases the efficiency of the stage that is caused by the intensification of stirring phases. While rotating the plates in the column reflux under heat rectification the overall efficiency of the stage increased 2 times. The highest efficiency of separation in distillation columns is achieved when the thermal difference between the steam temperature at the top stage and cooling water in this stage in a dephlegmator at is 8-25 °C. Recommendations for the use of the developed contact stages in columns thermal distillation are given.
format Article
id doaj-art-8bc67dab6c8442398d5ba2f928e1e911
institution DOAJ
issn 2074-9414
2313-1748
language English
publishDate 2017-03-01
publisher Kemerovo State University
record_format Article
series Техника и технология пищевых производств
spelling doaj-art-8bc67dab6c8442398d5ba2f928e1e9112025-08-20T02:58:04ZengKemerovo State UniversityТехника и технология пищевых производств2074-94142313-17482017-03-01441586410.21179/2074-9414-2017-1-58-64NONADIABATIC RECTIFICATION CONTACT DEVICESVoinov N.A.0Zemtsov D.A.1Zhukova O.P.2Siberian State Aerospace UniversitySiberian State Aerospace UniversitySiberian State Aerospace UniversityOn the basis of the developed method of heat rectification implying partial condensation of the vapor mixture rising along the height of the column and the resulting evaporation of condensate before it is mixed with the main stream of the flowing reflux the process of strengthening the ethanol-water mixture in the contact levels with high and low mass exchange is investigated and intensified. The process of nonadiabatic rectification was carried out on the contact steps, and then held in the columns with 24 contact stages. The intensive mass transfer was achieved using a vortex steps performed by tangential swirlers. Contact stages of low-mass exchange were made of horizontally installed profiled copper plates. The paper presents the technological parameters which change the flow regime of the rotating layer on vortex stage. The value of the hydraulic resistance coefficient of the device is also determined. The dependence for determining the effectiveness of the contact stage was estimated by Murphree. The efficiency depends on the stage of the vortex flow ratio, fluid bed height, Reynolds centrifugal rotating layer, and the slope of the equilibrium curve. In the study of the steps made of the plates it was revealed that the greatest contribution to the strengthening of the mixture isallowed by the processes of evaporation and condensation occurring on the upper plate of the unit. The dependence was revealed for assessing the effectiveness of the contact stage of the plates, which depends on the specific expenditure reflux and steam mixture, condensation and evaporation surfaces, and steam radial velocity between the plates. To intensify the separation process the effected reflux rotation plates were disposed on the lower stage of each column by installing them on the motor shaft. It is shown that rotation of the liquid intensifies the mass transfer in the liquid and vapor phases. It is established, that the increasing number of revolutions of the plate and the concentration of volatile component in the mixture increases the efficiency of the stage that is caused by the intensification of stirring phases. While rotating the plates in the column reflux under heat rectification the overall efficiency of the stage increased 2 times. The highest efficiency of separation in distillation columns is achieved when the thermal difference between the steam temperature at the top stage and cooling water in this stage in a dephlegmator at is 8-25 °C. Recommendations for the use of the developed contact stages in columns thermal distillation are given.http://fptt.ru/stories/archive/44/9.pdfnonadiabatic rectificationthermal rectificationcontact devicesefficiencyreflux ratio
spellingShingle Voinov N.A.
Zemtsov D.A.
Zhukova O.P.
NONADIABATIC RECTIFICATION CONTACT DEVICES
Техника и технология пищевых производств
nonadiabatic rectification
thermal rectification
contact devices
efficiency
reflux ratio
title NONADIABATIC RECTIFICATION CONTACT DEVICES
title_full NONADIABATIC RECTIFICATION CONTACT DEVICES
title_fullStr NONADIABATIC RECTIFICATION CONTACT DEVICES
title_full_unstemmed NONADIABATIC RECTIFICATION CONTACT DEVICES
title_short NONADIABATIC RECTIFICATION CONTACT DEVICES
title_sort nonadiabatic rectification contact devices
topic nonadiabatic rectification
thermal rectification
contact devices
efficiency
reflux ratio
url http://fptt.ru/stories/archive/44/9.pdf
work_keys_str_mv AT voinovna nonadiabaticrectificationcontactdevices
AT zemtsovda nonadiabaticrectificationcontactdevices
AT zhukovaop nonadiabaticrectificationcontactdevices