Analytical Characteristics and Clinical Performance of Anti-Müllerian Hormone Immunoassay on the ADVIA Centaur<sup>®</sup> System: A Comparison with Other Chemiluminescent Methods

Background: Serum anti-Müllerian hormone (AMH) levels and antral follicle count are key in evaluating ovarian reserve (OR) for fertility. The performance of the Siemens Healthineers AMH assay was assessed on the ADVIA Centaur<sup>®</sup> System. Methods: Analytical characteristics, clini...

Full description

Saved in:
Bibliographic Details
Main Authors: Jelena Bogdanovic, Kaitlin Freeman, Chadwick Brown, Rachel Singleton, Millie Behera, Jeanne E. O’Brien, Edward Zbella, Robert H. Christenson
Format: Article
Language:English
Published: MDPI AG 2024-11-01
Series:Endocrines
Subjects:
Online Access:https://www.mdpi.com/2673-396X/5/4/37
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850241435923644416
author Jelena Bogdanovic
Kaitlin Freeman
Chadwick Brown
Rachel Singleton
Millie Behera
Jeanne E. O’Brien
Edward Zbella
Robert H. Christenson
author_facet Jelena Bogdanovic
Kaitlin Freeman
Chadwick Brown
Rachel Singleton
Millie Behera
Jeanne E. O’Brien
Edward Zbella
Robert H. Christenson
author_sort Jelena Bogdanovic
collection DOAJ
description Background: Serum anti-Müllerian hormone (AMH) levels and antral follicle count are key in evaluating ovarian reserve (OR) for fertility. The performance of the Siemens Healthineers AMH assay was assessed on the ADVIA Centaur<sup>®</sup> System. Methods: Analytical characteristics, clinical performance, and method comparison studies were performed in a prospective cohort of 532 women at fertility clinics. Serum AMH levels were determined using ADVIA Centaur, Beckman Access<sup>®</sup>, and Roche Elecsys<sup>®</sup> assays. Results: The limit of quantitation for the ADVIA Centaur AMH assay was 0.030 ng/mL. Repeatability was ≤2.9% CV, within-lab repeatability was ≤3.2% CV, and reproducibility was ≤4.4% CV. Results using serum or lithium heparin sample types were equivalent. Diagnostic sensitivity across assays ranged from 77.3% to 90.2% and specificity ranged from 51.0 to 71.0%; corresponding positive and negative predictive values ranged from 66.6% to 74.3% and 74.2% to 83.0%, respectively. Receiver operating characteristic analyses demonstrated that the assays have a high probability for discriminating between diminished–normal and high OR. ADVIA and Beckman assays agreed according to ADVIA = 1.00 × Beckman + 0.014 ng/mL, τ = 0.909, while a more modest correlation of ADVIA = 1.41 × Roche − 0.024 ng/mL, τ = 0.777 was observed with Roche assay. Conclusions: The ADVIA Centaur assay demonstrates acceptable analytical characteristics and clinical performance comparable to the Roche AMH assay and is essentially interchangeable with the Beckman AMH assay for reliable OR assessment.
format Article
id doaj-art-8b8ac72ed32f4eaa8c8fef2b17077a1f
institution OA Journals
issn 2673-396X
language English
publishDate 2024-11-01
publisher MDPI AG
record_format Article
series Endocrines
spelling doaj-art-8b8ac72ed32f4eaa8c8fef2b17077a1f2025-08-20T02:00:37ZengMDPI AGEndocrines2673-396X2024-11-015451652810.3390/endocrines5040037Analytical Characteristics and Clinical Performance of Anti-Müllerian Hormone Immunoassay on the ADVIA Centaur<sup>®</sup> System: A Comparison with Other Chemiluminescent MethodsJelena Bogdanovic0Kaitlin Freeman1Chadwick Brown2Rachel Singleton3Millie Behera4Jeanne E. O’Brien5Edward Zbella6Robert H. Christenson7Siemens Healthineers, Tarrytown, NY 10591, USASiemens Healthineers, Tarrytown, NY 10591, USASiemens Healthineers, Tarrytown, NY 10591, USASiemens Healthineers, Tarrytown, NY 10591, USABloom Reproductive Institute, Scottsdale, AZ 85258, USAShady Grove Fertility Center, Rockville, MD 20850, USAWomen’s Medical Research Group, LLC, Clearwater, FL 33759, USAClinical Chemistry Research Lab, University of Maryland, Baltimore, MD 21201, USABackground: Serum anti-Müllerian hormone (AMH) levels and antral follicle count are key in evaluating ovarian reserve (OR) for fertility. The performance of the Siemens Healthineers AMH assay was assessed on the ADVIA Centaur<sup>®</sup> System. Methods: Analytical characteristics, clinical performance, and method comparison studies were performed in a prospective cohort of 532 women at fertility clinics. Serum AMH levels were determined using ADVIA Centaur, Beckman Access<sup>®</sup>, and Roche Elecsys<sup>®</sup> assays. Results: The limit of quantitation for the ADVIA Centaur AMH assay was 0.030 ng/mL. Repeatability was ≤2.9% CV, within-lab repeatability was ≤3.2% CV, and reproducibility was ≤4.4% CV. Results using serum or lithium heparin sample types were equivalent. Diagnostic sensitivity across assays ranged from 77.3% to 90.2% and specificity ranged from 51.0 to 71.0%; corresponding positive and negative predictive values ranged from 66.6% to 74.3% and 74.2% to 83.0%, respectively. Receiver operating characteristic analyses demonstrated that the assays have a high probability for discriminating between diminished–normal and high OR. ADVIA and Beckman assays agreed according to ADVIA = 1.00 × Beckman + 0.014 ng/mL, τ = 0.909, while a more modest correlation of ADVIA = 1.41 × Roche − 0.024 ng/mL, τ = 0.777 was observed with Roche assay. Conclusions: The ADVIA Centaur assay demonstrates acceptable analytical characteristics and clinical performance comparable to the Roche AMH assay and is essentially interchangeable with the Beckman AMH assay for reliable OR assessment.https://www.mdpi.com/2673-396X/5/4/37anti-Müllerian hormoneantral follicle countovarian reserveADVIA Centaurautomated analyzerprospective studies
spellingShingle Jelena Bogdanovic
Kaitlin Freeman
Chadwick Brown
Rachel Singleton
Millie Behera
Jeanne E. O’Brien
Edward Zbella
Robert H. Christenson
Analytical Characteristics and Clinical Performance of Anti-Müllerian Hormone Immunoassay on the ADVIA Centaur<sup>®</sup> System: A Comparison with Other Chemiluminescent Methods
Endocrines
anti-Müllerian hormone
antral follicle count
ovarian reserve
ADVIA Centaur
automated analyzer
prospective studies
title Analytical Characteristics and Clinical Performance of Anti-Müllerian Hormone Immunoassay on the ADVIA Centaur<sup>®</sup> System: A Comparison with Other Chemiluminescent Methods
title_full Analytical Characteristics and Clinical Performance of Anti-Müllerian Hormone Immunoassay on the ADVIA Centaur<sup>®</sup> System: A Comparison with Other Chemiluminescent Methods
title_fullStr Analytical Characteristics and Clinical Performance of Anti-Müllerian Hormone Immunoassay on the ADVIA Centaur<sup>®</sup> System: A Comparison with Other Chemiluminescent Methods
title_full_unstemmed Analytical Characteristics and Clinical Performance of Anti-Müllerian Hormone Immunoassay on the ADVIA Centaur<sup>®</sup> System: A Comparison with Other Chemiluminescent Methods
title_short Analytical Characteristics and Clinical Performance of Anti-Müllerian Hormone Immunoassay on the ADVIA Centaur<sup>®</sup> System: A Comparison with Other Chemiluminescent Methods
title_sort analytical characteristics and clinical performance of anti mullerian hormone immunoassay on the advia centaur sup r sup system a comparison with other chemiluminescent methods
topic anti-Müllerian hormone
antral follicle count
ovarian reserve
ADVIA Centaur
automated analyzer
prospective studies
url https://www.mdpi.com/2673-396X/5/4/37
work_keys_str_mv AT jelenabogdanovic analyticalcharacteristicsandclinicalperformanceofantimullerianhormoneimmunoassayontheadviacentaursupsupsystemacomparisonwithotherchemiluminescentmethods
AT kaitlinfreeman analyticalcharacteristicsandclinicalperformanceofantimullerianhormoneimmunoassayontheadviacentaursupsupsystemacomparisonwithotherchemiluminescentmethods
AT chadwickbrown analyticalcharacteristicsandclinicalperformanceofantimullerianhormoneimmunoassayontheadviacentaursupsupsystemacomparisonwithotherchemiluminescentmethods
AT rachelsingleton analyticalcharacteristicsandclinicalperformanceofantimullerianhormoneimmunoassayontheadviacentaursupsupsystemacomparisonwithotherchemiluminescentmethods
AT milliebehera analyticalcharacteristicsandclinicalperformanceofantimullerianhormoneimmunoassayontheadviacentaursupsupsystemacomparisonwithotherchemiluminescentmethods
AT jeanneeobrien analyticalcharacteristicsandclinicalperformanceofantimullerianhormoneimmunoassayontheadviacentaursupsupsystemacomparisonwithotherchemiluminescentmethods
AT edwardzbella analyticalcharacteristicsandclinicalperformanceofantimullerianhormoneimmunoassayontheadviacentaursupsupsystemacomparisonwithotherchemiluminescentmethods
AT roberthchristenson analyticalcharacteristicsandclinicalperformanceofantimullerianhormoneimmunoassayontheadviacentaursupsupsystemacomparisonwithotherchemiluminescentmethods