Studying the thermal condition of an automated 6 (10) Kv electric power fiscal metering location

THE PURPOSE. Examine the problem of reliable functioning of small electric power fiscal metering locations (EPFML) based on unconventional instrument current and voltage converters (Rogowski coil and resistive divider). Identify the most severe environmental conditions in which EPFML can be operated...

Full description

Saved in:
Bibliographic Details
Main Authors: E. E. Gotovkina, A. A. Yablokov, N. N. Smirnov, A. V. Panashatenko, V. D. Lebedev, O. A. Dobryagina
Format: Article
Language:English
Published: Kazan State Power Engineering University 2021-05-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/1770
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850158151250214912
author E. E. Gotovkina
A. A. Yablokov
N. N. Smirnov
A. V. Panashatenko
V. D. Lebedev
O. A. Dobryagina
author_facet E. E. Gotovkina
A. A. Yablokov
N. N. Smirnov
A. V. Panashatenko
V. D. Lebedev
O. A. Dobryagina
author_sort E. E. Gotovkina
collection DOAJ
description THE PURPOSE. Examine the problem of reliable functioning of small electric power fiscal metering locations (EPFML) based on unconventional instrument current and voltage converters (Rogowski coil and resistive divider). Identify the most severe environmental conditions in which EPFML can be operated. Conduct research into EPFML thermal condition in different grid operation modes, and also during high voltage testing. Determine the conditions in which heat emission at the resistor divider attains its maximum value. METHODS. To solve the problem, use was made of three-dimensional hybrid field and chain simulation models, calculated by the methods of finite elements and linear electric circuit theory. The developed simulation models enable research to be conducted not only in normal, but also emergency electric grid operation, during lightning and pulse surges, insulation testing, and in the presence of insolation. RESULTS. The article presents the results of research concerning the thermal condition of a 6 (10) kV automated electric power fiscal metering location. CONCLUSION. If a resistive divider is used as a primary voltage converter, maximum heat emission occurs in the event of intermittent single phase arc faults to earth in accordance with Petersen’s theory. The results of the conducted research show that an EPFML based on a resistive voltage divider should be calculated using simulated models, taking into account insolation and the daily pattern of changes in maximum ambient temperature.
format Article
id doaj-art-8b7e5e99a605499ebdee306723a94def
institution OA Journals
issn 1998-9903
language English
publishDate 2021-05-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj-art-8b7e5e99a605499ebdee306723a94def2025-08-20T02:23:57ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032021-05-0123118219610.30724/1998-9903-2021-23-1-182-196737Studying the thermal condition of an automated 6 (10) Kv electric power fiscal metering locationE. E. Gotovkina0A. A. Yablokov1N. N. Smirnov2A. V. Panashatenko3V. D. Lebedev4O. A. Dobryagina5Ivanovo State Power Engineering UniversityIvanovo State Power Engineering University; Research and Production Association "Digital Measurement Transformers"Ivanovo State Power Engineering UniversityResearch and Production Association "Digital Measurement Transformers"Ivanovo State Power Engineering University; Research and Production Association "Digital Measurement Transformers"Ivanovo State Power Engineering UniversityTHE PURPOSE. Examine the problem of reliable functioning of small electric power fiscal metering locations (EPFML) based on unconventional instrument current and voltage converters (Rogowski coil and resistive divider). Identify the most severe environmental conditions in which EPFML can be operated. Conduct research into EPFML thermal condition in different grid operation modes, and also during high voltage testing. Determine the conditions in which heat emission at the resistor divider attains its maximum value. METHODS. To solve the problem, use was made of three-dimensional hybrid field and chain simulation models, calculated by the methods of finite elements and linear electric circuit theory. The developed simulation models enable research to be conducted not only in normal, but also emergency electric grid operation, during lightning and pulse surges, insulation testing, and in the presence of insolation. RESULTS. The article presents the results of research concerning the thermal condition of a 6 (10) kV automated electric power fiscal metering location. CONCLUSION. If a resistive divider is used as a primary voltage converter, maximum heat emission occurs in the event of intermittent single phase arc faults to earth in accordance with Petersen’s theory. The results of the conducted research show that an EPFML based on a resistive voltage divider should be calculated using simulated models, taking into account insolation and the daily pattern of changes in maximum ambient temperature.https://www.energyret.ru/jour/article/view/1770compact electric power fiscal metering locationsmart electric power systemvoltage convertersingle phase earth faultinsolationthermal conditionsimulation model
spellingShingle E. E. Gotovkina
A. A. Yablokov
N. N. Smirnov
A. V. Panashatenko
V. D. Lebedev
O. A. Dobryagina
Studying the thermal condition of an automated 6 (10) Kv electric power fiscal metering location
Известия высших учебных заведений: Проблемы энергетики
compact electric power fiscal metering location
smart electric power system
voltage converter
single phase earth fault
insolation
thermal condition
simulation model
title Studying the thermal condition of an automated 6 (10) Kv electric power fiscal metering location
title_full Studying the thermal condition of an automated 6 (10) Kv electric power fiscal metering location
title_fullStr Studying the thermal condition of an automated 6 (10) Kv electric power fiscal metering location
title_full_unstemmed Studying the thermal condition of an automated 6 (10) Kv electric power fiscal metering location
title_short Studying the thermal condition of an automated 6 (10) Kv electric power fiscal metering location
title_sort studying the thermal condition of an automated 6 10 kv electric power fiscal metering location
topic compact electric power fiscal metering location
smart electric power system
voltage converter
single phase earth fault
insolation
thermal condition
simulation model
url https://www.energyret.ru/jour/article/view/1770
work_keys_str_mv AT eegotovkina studyingthethermalconditionofanautomated610kvelectricpowerfiscalmeteringlocation
AT aayablokov studyingthethermalconditionofanautomated610kvelectricpowerfiscalmeteringlocation
AT nnsmirnov studyingthethermalconditionofanautomated610kvelectricpowerfiscalmeteringlocation
AT avpanashatenko studyingthethermalconditionofanautomated610kvelectricpowerfiscalmeteringlocation
AT vdlebedev studyingthethermalconditionofanautomated610kvelectricpowerfiscalmeteringlocation
AT oadobryagina studyingthethermalconditionofanautomated610kvelectricpowerfiscalmeteringlocation