Predictability of central corneal stromal thickness reduction in InnovEyes ablation profile: A retrospective study

Objective: To evaluate the predictability of the central corneal stromal thickness (CST) reduction in InnovEyes ablation profile.Methods: The retrospective study included 118 eyes (61 patients) who underwent surgeries based on InnovEyes profile and 117 eyes (67 patients) based on the Custom-Q. The c...

Full description

Saved in:
Bibliographic Details
Main Authors: Shimin Tan, Yimeng Fan, Xindi Wang, Yu Zhang, Yunpeng Li, Xiaojuan Fan, Zhao Liu, Shengjian Mi, Qianyan Kang
Format: Article
Language:English
Published: Elsevier 2025-06-01
Series:Photodiagnosis and Photodynamic Therapy
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1572100025000997
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849701402388987904
author Shimin Tan
Yimeng Fan
Xindi Wang
Yu Zhang
Yunpeng Li
Xiaojuan Fan
Zhao Liu
Shengjian Mi
Qianyan Kang
author_facet Shimin Tan
Yimeng Fan
Xindi Wang
Yu Zhang
Yunpeng Li
Xiaojuan Fan
Zhao Liu
Shengjian Mi
Qianyan Kang
author_sort Shimin Tan
collection DOAJ
description Objective: To evaluate the predictability of the central corneal stromal thickness (CST) reduction in InnovEyes ablation profile.Methods: The retrospective study included 118 eyes (61 patients) who underwent surgeries based on InnovEyes profile and 117 eyes (67 patients) based on the Custom-Q. The central CST, the central corneal thickness (CT) and the central corneal epithelial thickness (CET) were measured using anterior segment optical coherence tomography (AS-OCT) preoperatively and postoperatively over 3 months. The planned-achieved thickness (PAD) was calculated. Planned and achieved central CST, PAD and increase of central CET were compared.Results: The achieved central CST reduction was 113.60 ± 21.88 μm in the InnovEyes group, which was not significantly different from the planned (108.70 ± 19.87 μm, P = 0.075). There was a strong correlation between the achieved central CST reduction and the planned reduction in the InnovEyes group (R2 = 0.884, P < 0.001), which was stronger than in the Custom-Q group (R2 = 0.861, P < 0.001). The PAD of central CST reduction was -4.87 ± 8.17 μm and -4.76 ± 9.75 μm for the InnovEyes and Custom-Q groups, respectively (P = 0.966). The increase of central CET was 3.29 ± 3.97 μm in InnovEyes group and 4.39 ± 4.84 μm in Custom-Q group, with no significant difference (P = 0.064).Conclusions: The InnovEyes ablation profile demonstrates good predictability of the central CST reduction, ensuring the safety of this novel profile. Besides, the InnovEyes profile may have taken postoperative corneal epithelial remodeling into consideration, and provided an enhanced pre-compensation.
format Article
id doaj-art-8b6f9cd9b5f5452684ca4acf056eff3d
institution DOAJ
issn 1572-1000
language English
publishDate 2025-06-01
publisher Elsevier
record_format Article
series Photodiagnosis and Photodynamic Therapy
spelling doaj-art-8b6f9cd9b5f5452684ca4acf056eff3d2025-08-20T03:17:57ZengElsevierPhotodiagnosis and Photodynamic Therapy1572-10002025-06-015310457010.1016/j.pdpdt.2025.104570Predictability of central corneal stromal thickness reduction in InnovEyes ablation profile: A retrospective studyShimin Tan0Yimeng Fan1Xindi Wang2Yu Zhang3Yunpeng Li4Xiaojuan Fan5Zhao Liu6Shengjian Mi7Qianyan Kang8Department of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR ChinaDepartment of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR ChinaDepartment of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR ChinaDepartment of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR ChinaDepartment of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR ChinaDepartment of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR ChinaCorrespondence author at. Department of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR China.; Department of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR ChinaDepartment of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR ChinaDepartment of Ophthalmology, the First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, Shaanxi, 710061, PR ChinaObjective: To evaluate the predictability of the central corneal stromal thickness (CST) reduction in InnovEyes ablation profile.Methods: The retrospective study included 118 eyes (61 patients) who underwent surgeries based on InnovEyes profile and 117 eyes (67 patients) based on the Custom-Q. The central CST, the central corneal thickness (CT) and the central corneal epithelial thickness (CET) were measured using anterior segment optical coherence tomography (AS-OCT) preoperatively and postoperatively over 3 months. The planned-achieved thickness (PAD) was calculated. Planned and achieved central CST, PAD and increase of central CET were compared.Results: The achieved central CST reduction was 113.60 ± 21.88 μm in the InnovEyes group, which was not significantly different from the planned (108.70 ± 19.87 μm, P = 0.075). There was a strong correlation between the achieved central CST reduction and the planned reduction in the InnovEyes group (R2 = 0.884, P < 0.001), which was stronger than in the Custom-Q group (R2 = 0.861, P < 0.001). The PAD of central CST reduction was -4.87 ± 8.17 μm and -4.76 ± 9.75 μm for the InnovEyes and Custom-Q groups, respectively (P = 0.966). The increase of central CET was 3.29 ± 3.97 μm in InnovEyes group and 4.39 ± 4.84 μm in Custom-Q group, with no significant difference (P = 0.064).Conclusions: The InnovEyes ablation profile demonstrates good predictability of the central CST reduction, ensuring the safety of this novel profile. Besides, the InnovEyes profile may have taken postoperative corneal epithelial remodeling into consideration, and provided an enhanced pre-compensation.http://www.sciencedirect.com/science/article/pii/S1572100025000997InnoveyesOptical ray tracingAblation profilesCorneal stromal thickness (CST)Anterior segment optical coherence tomography (AS‑OCT)
spellingShingle Shimin Tan
Yimeng Fan
Xindi Wang
Yu Zhang
Yunpeng Li
Xiaojuan Fan
Zhao Liu
Shengjian Mi
Qianyan Kang
Predictability of central corneal stromal thickness reduction in InnovEyes ablation profile: A retrospective study
Photodiagnosis and Photodynamic Therapy
Innoveyes
Optical ray tracing
Ablation profiles
Corneal stromal thickness (CST)
Anterior segment optical coherence tomography (AS‑OCT)
title Predictability of central corneal stromal thickness reduction in InnovEyes ablation profile: A retrospective study
title_full Predictability of central corneal stromal thickness reduction in InnovEyes ablation profile: A retrospective study
title_fullStr Predictability of central corneal stromal thickness reduction in InnovEyes ablation profile: A retrospective study
title_full_unstemmed Predictability of central corneal stromal thickness reduction in InnovEyes ablation profile: A retrospective study
title_short Predictability of central corneal stromal thickness reduction in InnovEyes ablation profile: A retrospective study
title_sort predictability of central corneal stromal thickness reduction in innoveyes ablation profile a retrospective study
topic Innoveyes
Optical ray tracing
Ablation profiles
Corneal stromal thickness (CST)
Anterior segment optical coherence tomography (AS‑OCT)
url http://www.sciencedirect.com/science/article/pii/S1572100025000997
work_keys_str_mv AT shimintan predictabilityofcentralcornealstromalthicknessreductionininnoveyesablationprofilearetrospectivestudy
AT yimengfan predictabilityofcentralcornealstromalthicknessreductionininnoveyesablationprofilearetrospectivestudy
AT xindiwang predictabilityofcentralcornealstromalthicknessreductionininnoveyesablationprofilearetrospectivestudy
AT yuzhang predictabilityofcentralcornealstromalthicknessreductionininnoveyesablationprofilearetrospectivestudy
AT yunpengli predictabilityofcentralcornealstromalthicknessreductionininnoveyesablationprofilearetrospectivestudy
AT xiaojuanfan predictabilityofcentralcornealstromalthicknessreductionininnoveyesablationprofilearetrospectivestudy
AT zhaoliu predictabilityofcentralcornealstromalthicknessreductionininnoveyesablationprofilearetrospectivestudy
AT shengjianmi predictabilityofcentralcornealstromalthicknessreductionininnoveyesablationprofilearetrospectivestudy
AT qianyankang predictabilityofcentralcornealstromalthicknessreductionininnoveyesablationprofilearetrospectivestudy