Impact of extubation failure on the duration of mechanical ventilation in the pediatric population

ABSTRACT Objective To compare the epidemiological profiles of patients who experienced extubation failure with those who achieved success and to evaluate the impact of extubation failure on total mechanical ventilation duration. Methods An observational study with both retrospective and prospect...

Full description

Saved in:
Bibliographic Details
Main Authors: Thamires de Carvalho Silvério, Cristiane do Prado, Milena Siciliano Nascimento
Format: Article
Language:English
Published: Instituto Israelita de Ensino e Pesquisa Albert Einstein 2025-05-01
Series:Einstein (São Paulo)
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082025000100224&lng=en&tlng=en
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850262768037396480
author Thamires de Carvalho Silvério
Cristiane do Prado
Milena Siciliano Nascimento
author_facet Thamires de Carvalho Silvério
Cristiane do Prado
Milena Siciliano Nascimento
author_sort Thamires de Carvalho Silvério
collection DOAJ
description ABSTRACT Objective To compare the epidemiological profiles of patients who experienced extubation failure with those who achieved success and to evaluate the impact of extubation failure on total mechanical ventilation duration. Methods An observational study with both retrospective and prospective components was conducted on patients admitted to the Pediatric Intensive Care Unit of a private hospital. This study included patients who underwent mechanical ventilation and were extubated between January 2017 and December 2022. Patients were classified into extubation Success or Failure Groups, with failure defined as requiring a return to invasive mechanical ventilation within 48hs post-extubation. Epidemiological factors, including age, pre-existing illnesses, and time on invasive mechanical ventilation, were analyzed. Results A total of 173 patients were included, of which 9 (5.2%) required reintubation within 48hs. The total duration of mechanical ventilation differed significantly between the Success Group (3 days [1.8; 6.6]) and the Failure Group (6.5 days [5.6; 9.3]), p=0.004. Upper airway obstruction was identified as the primary cause of extubation failure. Conclusion This study demonstrated that extubation failure doubled the total duration of mechanical ventilation compared to successful extubation. These findings highlight the importance of daily patient assessment with clearly defined clinical criteria to ensure mechanical ventilation is discontinued precisely when the patient is ready-neither prematurely nor excessively delayed.
format Article
id doaj-art-8b4a9f96bf6e473d8bfa10f6180cc31d
institution OA Journals
issn 2317-6385
language English
publishDate 2025-05-01
publisher Instituto Israelita de Ensino e Pesquisa Albert Einstein
record_format Article
series Einstein (São Paulo)
spelling doaj-art-8b4a9f96bf6e473d8bfa10f6180cc31d2025-08-20T01:55:08ZengInstituto Israelita de Ensino e Pesquisa Albert EinsteinEinstein (São Paulo)2317-63852025-05-012310.31744/einstein_journal/2025ao0705Impact of extubation failure on the duration of mechanical ventilation in the pediatric populationThamires de Carvalho Silvériohttps://orcid.org/0000-0003-1121-8286Cristiane do Pradohttps://orcid.org/0000-0002-2928-3986Milena Siciliano Nascimentohttps://orcid.org/0000-0002-0515-3933ABSTRACT Objective To compare the epidemiological profiles of patients who experienced extubation failure with those who achieved success and to evaluate the impact of extubation failure on total mechanical ventilation duration. Methods An observational study with both retrospective and prospective components was conducted on patients admitted to the Pediatric Intensive Care Unit of a private hospital. This study included patients who underwent mechanical ventilation and were extubated between January 2017 and December 2022. Patients were classified into extubation Success or Failure Groups, with failure defined as requiring a return to invasive mechanical ventilation within 48hs post-extubation. Epidemiological factors, including age, pre-existing illnesses, and time on invasive mechanical ventilation, were analyzed. Results A total of 173 patients were included, of which 9 (5.2%) required reintubation within 48hs. The total duration of mechanical ventilation differed significantly between the Success Group (3 days [1.8; 6.6]) and the Failure Group (6.5 days [5.6; 9.3]), p=0.004. Upper airway obstruction was identified as the primary cause of extubation failure. Conclusion This study demonstrated that extubation failure doubled the total duration of mechanical ventilation compared to successful extubation. These findings highlight the importance of daily patient assessment with clearly defined clinical criteria to ensure mechanical ventilation is discontinued precisely when the patient is ready-neither prematurely nor excessively delayed.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082025000100224&lng=en&tlng=enAirway extubationRespiration, artificialVentilator weaningIntensive care unitsPediatricChild
spellingShingle Thamires de Carvalho Silvério
Cristiane do Prado
Milena Siciliano Nascimento
Impact of extubation failure on the duration of mechanical ventilation in the pediatric population
Einstein (São Paulo)
Airway extubation
Respiration, artificial
Ventilator weaning
Intensive care units
Pediatric
Child
title Impact of extubation failure on the duration of mechanical ventilation in the pediatric population
title_full Impact of extubation failure on the duration of mechanical ventilation in the pediatric population
title_fullStr Impact of extubation failure on the duration of mechanical ventilation in the pediatric population
title_full_unstemmed Impact of extubation failure on the duration of mechanical ventilation in the pediatric population
title_short Impact of extubation failure on the duration of mechanical ventilation in the pediatric population
title_sort impact of extubation failure on the duration of mechanical ventilation in the pediatric population
topic Airway extubation
Respiration, artificial
Ventilator weaning
Intensive care units
Pediatric
Child
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082025000100224&lng=en&tlng=en
work_keys_str_mv AT thamiresdecarvalhosilverio impactofextubationfailureonthedurationofmechanicalventilationinthepediatricpopulation
AT cristianedoprado impactofextubationfailureonthedurationofmechanicalventilationinthepediatricpopulation
AT milenasicilianonascimento impactofextubationfailureonthedurationofmechanicalventilationinthepediatricpopulation