Determination of Organophosphorus Esters in Fall Protection Equipment by Accelerated Solvent Extraction and Solid-Phase Extraction Coupled with LC-MS/MS Detection

An analysis method was established to determine 14 organophosphorus ester (OPE) flame retardants in fall protection equipment by combining accelerated solvent extraction (ASE) and solid-phase extraction (SPE) with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The ASE...

Full description

Saved in:
Bibliographic Details
Main Authors: Haihong Li, Mingli Ye, Fangfang Wu, Xuyang Zhao, Lifeng Wang, Yili Wei, Shengyi Xie, Hairong Cui
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Journal of Analytical Methods in Chemistry
Online Access:http://dx.doi.org/10.1155/2021/8878247
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832550569958440960
author Haihong Li
Mingli Ye
Fangfang Wu
Xuyang Zhao
Lifeng Wang
Yili Wei
Shengyi Xie
Hairong Cui
author_facet Haihong Li
Mingli Ye
Fangfang Wu
Xuyang Zhao
Lifeng Wang
Yili Wei
Shengyi Xie
Hairong Cui
author_sort Haihong Li
collection DOAJ
description An analysis method was established to determine 14 organophosphorus ester (OPE) flame retardants in fall protection equipment by combining accelerated solvent extraction (ASE) and solid-phase extraction (SPE) with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The ASE parameters were optimized as follows: static extraction with acetonitrile at 80°C for 5 min for two cycles. The combined extract was purified with the ENVI-18 cartridge before further analysis. A HILIC column was used to separate the OPEs using an acetonitrile/water mixture as the mobile phase with the detection by the electrospray ionization mass spectrometry, which was operated under the positive mode. Under optimized conditions, the limit of detection for the target OPEs ranged in 0.015–1.33 ng/g, with a spike recovery of 71.6%–114% and a relative standard deviation of 0.8%–11.2%. The developed method was used to analyze OPEs in fall protection equipment (safety helmets and ropes), where OPEs were all detectable. Safety ropes displayed a higher concentration of OPEs than ones in safety helmets, with the pollutants being mainly triphenyl phosphate, 2-ethylhexyl diphenyl phosphate (EHDPP), tri(2-ethylhexyl) phosphate, and tri-n-butyl phosphate in the range of 11.07 ng/g‒815.53 ng/g. The EHDPP was the dominant compound in safety helmets with the concentration from 26.84 to 95.29 ng/g, while the other OPEs in safety helmets were lower than 5.136 ng/g. The potential health and environmental risks of these fall protection equipment during their use and disposal call for further attention.
format Article
id doaj-art-898f3a3de49e40669cd8ec913d7cc565
institution Kabale University
issn 2090-8865
2090-8873
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Journal of Analytical Methods in Chemistry
spelling doaj-art-898f3a3de49e40669cd8ec913d7cc5652025-02-03T06:06:27ZengWileyJournal of Analytical Methods in Chemistry2090-88652090-88732021-01-01202110.1155/2021/88782478878247Determination of Organophosphorus Esters in Fall Protection Equipment by Accelerated Solvent Extraction and Solid-Phase Extraction Coupled with LC-MS/MS DetectionHaihong Li0Mingli Ye1Fangfang Wu2Xuyang Zhao3Lifeng Wang4Yili Wei5Shengyi Xie6Hairong Cui7Zhejiang Key Laboratory for Protection Technology of High-Rise Operation, Zhejiang Huadian Equipment Testing Institute Co., Ltd, Hangzhou, Zhejiang 310015, ChinaSchool of Life Science, Wuchang University of Technology, Wuhan, Hubei 430223, ChinaZhejiang Key Laboratory for Protection Technology of High-Rise Operation, Zhejiang Huadian Equipment Testing Institute Co., Ltd, Hangzhou, Zhejiang 310015, ChinaZhejiang Key Laboratory for Protection Technology of High-Rise Operation, Zhejiang Huadian Equipment Testing Institute Co., Ltd, Hangzhou, Zhejiang 310015, ChinaZhejiang Key Laboratory for Protection Technology of High-Rise Operation, Zhejiang Huadian Equipment Testing Institute Co., Ltd, Hangzhou, Zhejiang 310015, ChinaZhejiang Key Laboratory for Protection Technology of High-Rise Operation, Zhejiang Huadian Equipment Testing Institute Co., Ltd, Hangzhou, Zhejiang 310015, ChinaZhejiang Key Laboratory for Protection Technology of High-Rise Operation, Zhejiang Huadian Equipment Testing Institute Co., Ltd, Hangzhou, Zhejiang 310015, ChinaSchool of Life Science, Wuchang University of Technology, Wuhan, Hubei 430223, ChinaAn analysis method was established to determine 14 organophosphorus ester (OPE) flame retardants in fall protection equipment by combining accelerated solvent extraction (ASE) and solid-phase extraction (SPE) with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The ASE parameters were optimized as follows: static extraction with acetonitrile at 80°C for 5 min for two cycles. The combined extract was purified with the ENVI-18 cartridge before further analysis. A HILIC column was used to separate the OPEs using an acetonitrile/water mixture as the mobile phase with the detection by the electrospray ionization mass spectrometry, which was operated under the positive mode. Under optimized conditions, the limit of detection for the target OPEs ranged in 0.015–1.33 ng/g, with a spike recovery of 71.6%–114% and a relative standard deviation of 0.8%–11.2%. The developed method was used to analyze OPEs in fall protection equipment (safety helmets and ropes), where OPEs were all detectable. Safety ropes displayed a higher concentration of OPEs than ones in safety helmets, with the pollutants being mainly triphenyl phosphate, 2-ethylhexyl diphenyl phosphate (EHDPP), tri(2-ethylhexyl) phosphate, and tri-n-butyl phosphate in the range of 11.07 ng/g‒815.53 ng/g. The EHDPP was the dominant compound in safety helmets with the concentration from 26.84 to 95.29 ng/g, while the other OPEs in safety helmets were lower than 5.136 ng/g. The potential health and environmental risks of these fall protection equipment during their use and disposal call for further attention.http://dx.doi.org/10.1155/2021/8878247
spellingShingle Haihong Li
Mingli Ye
Fangfang Wu
Xuyang Zhao
Lifeng Wang
Yili Wei
Shengyi Xie
Hairong Cui
Determination of Organophosphorus Esters in Fall Protection Equipment by Accelerated Solvent Extraction and Solid-Phase Extraction Coupled with LC-MS/MS Detection
Journal of Analytical Methods in Chemistry
title Determination of Organophosphorus Esters in Fall Protection Equipment by Accelerated Solvent Extraction and Solid-Phase Extraction Coupled with LC-MS/MS Detection
title_full Determination of Organophosphorus Esters in Fall Protection Equipment by Accelerated Solvent Extraction and Solid-Phase Extraction Coupled with LC-MS/MS Detection
title_fullStr Determination of Organophosphorus Esters in Fall Protection Equipment by Accelerated Solvent Extraction and Solid-Phase Extraction Coupled with LC-MS/MS Detection
title_full_unstemmed Determination of Organophosphorus Esters in Fall Protection Equipment by Accelerated Solvent Extraction and Solid-Phase Extraction Coupled with LC-MS/MS Detection
title_short Determination of Organophosphorus Esters in Fall Protection Equipment by Accelerated Solvent Extraction and Solid-Phase Extraction Coupled with LC-MS/MS Detection
title_sort determination of organophosphorus esters in fall protection equipment by accelerated solvent extraction and solid phase extraction coupled with lc ms ms detection
url http://dx.doi.org/10.1155/2021/8878247
work_keys_str_mv AT haihongli determinationoforganophosphorusestersinfallprotectionequipmentbyacceleratedsolventextractionandsolidphaseextractioncoupledwithlcmsmsdetection
AT mingliye determinationoforganophosphorusestersinfallprotectionequipmentbyacceleratedsolventextractionandsolidphaseextractioncoupledwithlcmsmsdetection
AT fangfangwu determinationoforganophosphorusestersinfallprotectionequipmentbyacceleratedsolventextractionandsolidphaseextractioncoupledwithlcmsmsdetection
AT xuyangzhao determinationoforganophosphorusestersinfallprotectionequipmentbyacceleratedsolventextractionandsolidphaseextractioncoupledwithlcmsmsdetection
AT lifengwang determinationoforganophosphorusestersinfallprotectionequipmentbyacceleratedsolventextractionandsolidphaseextractioncoupledwithlcmsmsdetection
AT yiliwei determinationoforganophosphorusestersinfallprotectionequipmentbyacceleratedsolventextractionandsolidphaseextractioncoupledwithlcmsmsdetection
AT shengyixie determinationoforganophosphorusestersinfallprotectionequipmentbyacceleratedsolventextractionandsolidphaseextractioncoupledwithlcmsmsdetection
AT hairongcui determinationoforganophosphorusestersinfallprotectionequipmentbyacceleratedsolventextractionandsolidphaseextractioncoupledwithlcmsmsdetection