Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study
Objective: This study aimed to investigate the mechanical stability of a modified pedicle screw fixator and compare it with unilateral lumbopelvic fixation for treating sacroiliac joint disruption using finite element simulation technology. Methods: The digital model of a normal spine-pelvis-femu...
Saved in:
| Main Authors: | Jun Zhang, Yan Wei, Baoqing Yu, JianWang, Weizhong Yin |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
AVES
2024-09-01
|
| Series: | Acta Orthopaedica et Traumatologica Turcica |
| Online Access: | https://www.aott.org.tr/en/comparison-of-mechanical-stability-of-modified-pedicle-screw-fixator-and-unilateral-lumbopelvic-fixation-for-treating-sacroiliac-joint-disruption-a-finite-element-analysis-study-137426 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Finite element analysis of modified pedicle screw fixation and traditional lumbopelvic fixation for the treatment of sacroiliac joint disruption
by: Jun Zhang, et al.
Published: (2024-12-01) -
Biomechanical Comparison of a Novel Facet Joint Fusion Fixation Device With Conventional Pedicle Screw Fixation Device: A Finite Element Analysis
by: Feilong Sun, et al.
Published: (2025-04-01) -
Finite element analysis of pedicle screw fixation biomechanics and adjacent segment degeneration in varied bone conditions
by: Linling Zhang, et al.
Published: (2025-05-01) -
Unilateral versus bilateral pedicle screw fixation for treating two-level lumbar degenerative diseases
by: Ke Yang, et al.
Published: (2025-07-01) -
Mid-term efficacy of OLIF combined with unilateral pedicle screw fixation in the treatment of lumbar degenerative diseases
by: Zhiqiang Wang, et al.
Published: (2025-05-01)