Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study

Objective: This study aimed to investigate the mechanical stability of a modified pedicle screw fixator and compare it with unilateral lumbopelvic fixation for treating sacroiliac joint disruption using finite element simulation technology. Methods: The digital model of a normal spine-pelvis-femu...

Full description

Saved in:
Bibliographic Details
Main Authors: Jun Zhang, Yan Wei, Baoqing Yu, JianWang, Weizhong Yin
Format: Article
Language:English
Published: AVES 2024-09-01
Series:Acta Orthopaedica et Traumatologica Turcica
Online Access:https://www.aott.org.tr/en/comparison-of-mechanical-stability-of-modified-pedicle-screw-fixator-and-unilateral-lumbopelvic-fixation-for-treating-sacroiliac-joint-disruption-a-finite-element-analysis-study-137426
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849251436403097600
author Jun Zhang
Yan Wei
Baoqing Yu
JianWang
Weizhong Yin
author_facet Jun Zhang
Yan Wei
Baoqing Yu
JianWang
Weizhong Yin
author_sort Jun Zhang
collection DOAJ
description Objective: This study aimed to investigate the mechanical stability of a modified pedicle screw fixator and compare it with unilateral lumbopelvic fixation for treating sacroiliac joint disruption using finite element simulation technology. Methods: The digital model of a normal spine-pelvis-femur containing the main pelvic and lumbar ligaments was established based on computed tomography images. A sacroiliac joint disruption model was built and validated, which was stabilized with the models of a modified pedicle screw fixator or unilateral lumbopelvic fixation. A 400 N follower loading was applied to the lumbar vertebrae for the 2 fixation models to analyze displacement and stress distribution. In addition, the construct stiffness was calculated. Results: The peak amounts of sacral vertical displacement, horizontal displacement, posterior displacement, and overall displacement were 0.70 mm, 0.17 mm, 0.73 mm, and 0.88 mm, respectively, in the modified pedicle screw fixator model, which were less than those in the unilateral lumbopelvic fixation model (1.17 mm, 0.31 mm, 2.21 mm, and 2.29 mm, respectively). Compared with unilateral lumbopelvic fixation, the percentage decreases of the modified pedicle screw fixators were 40.2%, 45.2%, 67.0%, and 61.6%, respectively. The peak stress of the internal fixation and pelvis in the modified pedicle screw fixator model was 351.23 MPa and 39.91 MPa, which has 15.5% and 70.4% lower than in the unilateral lumbopelvic fixation model. The construct stiffness of the modified pedicle screw fixator (571 N/ mm) was 67% better than that of unilateral lumbopelvic fixation (342 N/mm). Conclusion: The finite element simulation results showed that the modified pedicle screw fixator model demonstrated smaller sacral displacement, fewer stresses on the internal fixation and bone, and higher construct stiffness compared with the unilateral lumbopelvic fixation model. Thus, the modified pedicle screw fixator may provide biomechanical advantages over unilateral lumbopelvic fixation in the treatment of sacroiliac joint disruption.
format Article
id doaj-art-893f7b866b8a4d5e84d32587e6117b4e
institution Kabale University
issn 1017-995X
language English
publishDate 2024-09-01
publisher AVES
record_format Article
series Acta Orthopaedica et Traumatologica Turcica
spelling doaj-art-893f7b866b8a4d5e84d32587e6117b4e2025-08-20T03:56:58ZengAVESActa Orthopaedica et Traumatologica Turcica1017-995X2024-09-0158527427910.5152/j.aott.2024.24072Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis studyJun Zhang0Yan Wei1Baoqing Yu2JianWang3Weizhong Yin4Department of Orthopedics, Pudong New Area People’s Hospital, Shanghai, ChinaDepartment of Surgery, Pudong New Area People’s Hospital, Shanghai, ChinaDepartment of Orthopedics, Seventh People’s Hospital of Shanghai University of TCM, Shanghai, ChinaDepartment of Orthopedics, Pudong New Area People’s Hospital, Shanghai, ChinaDepartment of Orthopedics, Pudong New Area People’s Hospital, Shanghai, ChinaObjective: This study aimed to investigate the mechanical stability of a modified pedicle screw fixator and compare it with unilateral lumbopelvic fixation for treating sacroiliac joint disruption using finite element simulation technology. Methods: The digital model of a normal spine-pelvis-femur containing the main pelvic and lumbar ligaments was established based on computed tomography images. A sacroiliac joint disruption model was built and validated, which was stabilized with the models of a modified pedicle screw fixator or unilateral lumbopelvic fixation. A 400 N follower loading was applied to the lumbar vertebrae for the 2 fixation models to analyze displacement and stress distribution. In addition, the construct stiffness was calculated. Results: The peak amounts of sacral vertical displacement, horizontal displacement, posterior displacement, and overall displacement were 0.70 mm, 0.17 mm, 0.73 mm, and 0.88 mm, respectively, in the modified pedicle screw fixator model, which were less than those in the unilateral lumbopelvic fixation model (1.17 mm, 0.31 mm, 2.21 mm, and 2.29 mm, respectively). Compared with unilateral lumbopelvic fixation, the percentage decreases of the modified pedicle screw fixators were 40.2%, 45.2%, 67.0%, and 61.6%, respectively. The peak stress of the internal fixation and pelvis in the modified pedicle screw fixator model was 351.23 MPa and 39.91 MPa, which has 15.5% and 70.4% lower than in the unilateral lumbopelvic fixation model. The construct stiffness of the modified pedicle screw fixator (571 N/ mm) was 67% better than that of unilateral lumbopelvic fixation (342 N/mm). Conclusion: The finite element simulation results showed that the modified pedicle screw fixator model demonstrated smaller sacral displacement, fewer stresses on the internal fixation and bone, and higher construct stiffness compared with the unilateral lumbopelvic fixation model. Thus, the modified pedicle screw fixator may provide biomechanical advantages over unilateral lumbopelvic fixation in the treatment of sacroiliac joint disruption.https://www.aott.org.tr/en/comparison-of-mechanical-stability-of-modified-pedicle-screw-fixator-and-unilateral-lumbopelvic-fixation-for-treating-sacroiliac-joint-disruption-a-finite-element-analysis-study-137426
spellingShingle Jun Zhang
Yan Wei
Baoqing Yu
JianWang
Weizhong Yin
Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study
Acta Orthopaedica et Traumatologica Turcica
title Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study
title_full Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study
title_fullStr Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study
title_full_unstemmed Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study
title_short Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study
title_sort comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption a finite element analysis study
url https://www.aott.org.tr/en/comparison-of-mechanical-stability-of-modified-pedicle-screw-fixator-and-unilateral-lumbopelvic-fixation-for-treating-sacroiliac-joint-disruption-a-finite-element-analysis-study-137426
work_keys_str_mv AT junzhang comparisonofmechanicalstabilityofmodifiedpediclescrewfixatorandunilaterallumbopelvicfixationfortreatingsacroiliacjointdisruptionafiniteelementanalysisstudy
AT yanwei comparisonofmechanicalstabilityofmodifiedpediclescrewfixatorandunilaterallumbopelvicfixationfortreatingsacroiliacjointdisruptionafiniteelementanalysisstudy
AT baoqingyu comparisonofmechanicalstabilityofmodifiedpediclescrewfixatorandunilaterallumbopelvicfixationfortreatingsacroiliacjointdisruptionafiniteelementanalysisstudy
AT jianwang comparisonofmechanicalstabilityofmodifiedpediclescrewfixatorandunilaterallumbopelvicfixationfortreatingsacroiliacjointdisruptionafiniteelementanalysisstudy
AT weizhongyin comparisonofmechanicalstabilityofmodifiedpediclescrewfixatorandunilaterallumbopelvicfixationfortreatingsacroiliacjointdisruptionafiniteelementanalysisstudy