A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years
Background. Implantable collamer lens (ICL) might rarely cause complications that warrant explantation. Here, we presented a case of inverted ICL that has undergone explantation after a 10-year duration. Case Presentation. A 49-year-old male with past ocular history of ICL implantation 10 years ago...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2021-01-01
|
| Series: | Case Reports in Ophthalmological Medicine |
| Online Access: | http://dx.doi.org/10.1155/2021/6641475 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850211619634675712 |
|---|---|
| author | Bader S. AlQahtani Abdulaziz A. Alshamrani Raed E. Alsulami Jose M. Vargas |
| author_facet | Bader S. AlQahtani Abdulaziz A. Alshamrani Raed E. Alsulami Jose M. Vargas |
| author_sort | Bader S. AlQahtani |
| collection | DOAJ |
| description | Background. Implantable collamer lens (ICL) might rarely cause complications that warrant explantation. Here, we presented a case of inverted ICL that has undergone explantation after a 10-year duration. Case Presentation. A 49-year-old male with past ocular history of ICL implantation 10 years ago presented complaining of progressive decrease of visual acuity in the left eye for a long time. On examination, decreased visual acuity, anterior subcapsular cataract, and low ICL vault were noted. The anterior segment optical coherence tomography (AS OCT) showed inverted ICL. The ICL was explanted, and cataract surgery was done. Conclusion. Inverted ICL should be kept in mind as a rare cause of long-term poor visual acuity in patient with a history of ICL surgery. |
| format | Article |
| id | doaj-art-88b5a0c642cb4fcc8d9bb6144a21c2d7 |
| institution | OA Journals |
| issn | 2090-6722 2090-6730 |
| language | English |
| publishDate | 2021-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | Case Reports in Ophthalmological Medicine |
| spelling | doaj-art-88b5a0c642cb4fcc8d9bb6144a21c2d72025-08-20T02:09:31ZengWileyCase Reports in Ophthalmological Medicine2090-67222090-67302021-01-01202110.1155/2021/66414756641475A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 YearsBader S. AlQahtani0Abdulaziz A. Alshamrani1Raed E. Alsulami2Jose M. Vargas3King Abdulaziz Medical City, Jeddah, Saudi ArabiaKing Khaled Eye Specialist Hospital, Riyadh, Saudi ArabiaJeddah Eye Hospital, Jeddah, Saudi ArabiaKing Khaled Eye Specialist Hospital, Riyadh, Saudi ArabiaBackground. Implantable collamer lens (ICL) might rarely cause complications that warrant explantation. Here, we presented a case of inverted ICL that has undergone explantation after a 10-year duration. Case Presentation. A 49-year-old male with past ocular history of ICL implantation 10 years ago presented complaining of progressive decrease of visual acuity in the left eye for a long time. On examination, decreased visual acuity, anterior subcapsular cataract, and low ICL vault were noted. The anterior segment optical coherence tomography (AS OCT) showed inverted ICL. The ICL was explanted, and cataract surgery was done. Conclusion. Inverted ICL should be kept in mind as a rare cause of long-term poor visual acuity in patient with a history of ICL surgery.http://dx.doi.org/10.1155/2021/6641475 |
| spellingShingle | Bader S. AlQahtani Abdulaziz A. Alshamrani Raed E. Alsulami Jose M. Vargas A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years Case Reports in Ophthalmological Medicine |
| title | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
| title_full | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
| title_fullStr | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
| title_full_unstemmed | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
| title_short | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
| title_sort | case of implantable collamer lens icl with reverse orientation for 10 years |
| url | http://dx.doi.org/10.1155/2021/6641475 |
| work_keys_str_mv | AT badersalqahtani acaseofimplantablecollamerlensiclwithreverseorientationfor10years AT abdulazizaalshamrani acaseofimplantablecollamerlensiclwithreverseorientationfor10years AT raedealsulami acaseofimplantablecollamerlensiclwithreverseorientationfor10years AT josemvargas acaseofimplantablecollamerlensiclwithreverseorientationfor10years AT badersalqahtani caseofimplantablecollamerlensiclwithreverseorientationfor10years AT abdulazizaalshamrani caseofimplantablecollamerlensiclwithreverseorientationfor10years AT raedealsulami caseofimplantablecollamerlensiclwithreverseorientationfor10years AT josemvargas caseofimplantablecollamerlensiclwithreverseorientationfor10years |