Influence of Limitations on Possible Graph Ordinate Values of Electrical Load on Rated Values of Load Peaks and Troughs

The influence of limitations on possible theta-ordinate values of group non-uniform electrical load graphs on the rated values of theta peaks and theta troughs and, particularly, on the rated heating load value is considered in the paper. It is shown that neglect of limitations on graph theta- ordin...

Full description

Saved in:
Bibliographic Details
Main Authors: I. V. Zhezhelenko, V. P. Stiepanov, А. V. Gudkov, R. Ph. Idiatulin
Format: Article
Language:Russian
Published: Belarusian National Technical University 2006-04-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Online Access:https://energy.bntu.by/jour/article/view/781
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543721151791104
author I. V. Zhezhelenko
V. P. Stiepanov
А. V. Gudkov
R. Ph. Idiatulin
author_facet I. V. Zhezhelenko
V. P. Stiepanov
А. V. Gudkov
R. Ph. Idiatulin
author_sort I. V. Zhezhelenko
collection DOAJ
description The influence of limitations on possible theta-ordinate values of group non-uniform electrical load graphs on the rated values of theta peaks and theta troughs and, particularly, on the rated heating load value is considered in the paper. It is shown that neglect of limitations on graph theta- ordinates of an electrical load leads in some cases to errors in evaluation of load theta peaks and theta troughs that exceed the tolerable values by ±10 %.
format Article
id doaj-art-881d50a2956b41e6ab12330957947a38
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2006-04-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-881d50a2956b41e6ab12330957947a382025-02-03T11:34:21ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412006-04-0102512774Influence of Limitations on Possible Graph Ordinate Values of Electrical Load on Rated Values of Load Peaks and TroughsI. V. ZhezhelenkoV. P. StiepanovА. V. GudkovR. Ph. IdiatulinThe influence of limitations on possible theta-ordinate values of group non-uniform electrical load graphs on the rated values of theta peaks and theta troughs and, particularly, on the rated heating load value is considered in the paper. It is shown that neglect of limitations on graph theta- ordinates of an electrical load leads in some cases to errors in evaluation of load theta peaks and theta troughs that exceed the tolerable values by ±10 %.https://energy.bntu.by/jour/article/view/781
spellingShingle I. V. Zhezhelenko
V. P. Stiepanov
А. V. Gudkov
R. Ph. Idiatulin
Influence of Limitations on Possible Graph Ordinate Values of Electrical Load on Rated Values of Load Peaks and Troughs
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
title Influence of Limitations on Possible Graph Ordinate Values of Electrical Load on Rated Values of Load Peaks and Troughs
title_full Influence of Limitations on Possible Graph Ordinate Values of Electrical Load on Rated Values of Load Peaks and Troughs
title_fullStr Influence of Limitations on Possible Graph Ordinate Values of Electrical Load on Rated Values of Load Peaks and Troughs
title_full_unstemmed Influence of Limitations on Possible Graph Ordinate Values of Electrical Load on Rated Values of Load Peaks and Troughs
title_short Influence of Limitations on Possible Graph Ordinate Values of Electrical Load on Rated Values of Load Peaks and Troughs
title_sort influence of limitations on possible graph ordinate values of electrical load on rated values of load peaks and troughs
url https://energy.bntu.by/jour/article/view/781
work_keys_str_mv AT ivzhezhelenko influenceoflimitationsonpossiblegraphordinatevaluesofelectricalloadonratedvaluesofloadpeaksandtroughs
AT vpstiepanov influenceoflimitationsonpossiblegraphordinatevaluesofelectricalloadonratedvaluesofloadpeaksandtroughs
AT avgudkov influenceoflimitationsonpossiblegraphordinatevaluesofelectricalloadonratedvaluesofloadpeaksandtroughs
AT rphidiatulin influenceoflimitationsonpossiblegraphordinatevaluesofelectricalloadonratedvaluesofloadpeaksandtroughs