Numerical investigation on fluid-thermal-electric performance of a thermoelectric-integrated helically coiled tube heat exchanger for coal mine air cooling

Mine cooling and refrigeration system to deal with the heat hazard is well developed, but the mine air cooler which serves as the most important terminal equipment is relatively backward. The severe heat hazard and urgent cooling demand in deep underground mines necessitate further improvement of co...

Full description

Saved in:
Bibliographic Details
Main Authors: Lu Xing, Dai Renkun, Deng Jun, Ma Ting
Format: Article
Language:English
Published: De Gruyter 2025-02-01
Series:Open Physics
Subjects:
Online Access:https://doi.org/10.1515/phys-2025-0123
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850080052468776960
author Lu Xing
Dai Renkun
Deng Jun
Ma Ting
author_facet Lu Xing
Dai Renkun
Deng Jun
Ma Ting
author_sort Lu Xing
collection DOAJ
description Mine cooling and refrigeration system to deal with the heat hazard is well developed, but the mine air cooler which serves as the most important terminal equipment is relatively backward. The severe heat hazard and urgent cooling demand in deep underground mines necessitate further improvement of cooling capacity and effectiveness under strict requirements such as being compact, portable, nontoxic, and no-pollution. The thermoelectric (TE) energy conversion technology has great potential in cooling and miniaturization applications, which can meet the strict requirements of the underground mine cooling devices. Yet, a research gap exists in integrating TE energy conversion technology with the traditional air-cooling heat exchanger to the best of our knowledge. In this work, a hybrid utilization of TE and the helically coiled tube heat exchanger (HCEX) is proposed for air cooling at the working face of underground mine. The advantage of the TE-integrated HCEX lies in the combination of the heat transfer enhancement effect by secondary flow induced inside the helically coiled tube and the solid-state Peltier cooling effect by the TE module positioned on the external shell wall of the heat exchanger, which can potentially improve the air-cooling capacity without occupying large space. A numerical simulation of the fluid-thermal-electric multiphysics field is performed to investigate the cooling rate and the effectiveness of the TE-integrated HCEX. Results show that additional cooling power can be effectively provided by TE. As the filling ratio (FR) of TE module on the external shell wall increases from 50 to 100%, the air-cooling capacity continuously increases, performing better than that of the conventional HCEX. The effect of air inlet temperature and inlet velocity on the cooling performance is investigated for the best design of the TE-integrated HCEX with FR of 100%. When the inlet temperature of air increases from 303.15 to 313.15 K under constant inlet velocity, the cooling rate increases and cooling effectiveness decreases. Also, the cooling rate increases and the cooling effectiveness decreases when the inlet velocity of air increases from 10 to 25 m s−1 under constant inlet temperature. Within the simulated range of air inlet conditions in this work, the maximum total cooling rate Q c,total at optimal current of 6 A for the TE-integrated HCEX results in an enhancement of 49.8 to 35.0% compared to the conventional HCEX. The maximum cooling effectiveness at optimal current of 6 A is 21.73–26.49% for the TE-integrated HCEX, which is higher than the effectiveness of the conventional HCEX of 15.74–18.24%.
format Article
id doaj-art-87a9c600d5f54c70afcea2f9c300857a
institution DOAJ
issn 2391-5471
language English
publishDate 2025-02-01
publisher De Gruyter
record_format Article
series Open Physics
spelling doaj-art-87a9c600d5f54c70afcea2f9c300857a2025-08-20T02:45:02ZengDe GruyterOpen Physics2391-54712025-02-0123111510.1515/phys-2025-0123Numerical investigation on fluid-thermal-electric performance of a thermoelectric-integrated helically coiled tube heat exchanger for coal mine air coolingLu Xing0Dai Renkun1Deng Jun2Ma Ting3School of Safety Science and Engineering, Xi’an University of Science and Technology, Xi’an, Shaanxi, 710054, PR ChinaSchool of Safety Science and Engineering, Xi’an University of Science and Technology, Xi’an, Shaanxi, 710054, PR ChinaSchool of Safety Science and Engineering, Xi’an University of Science and Technology, Xi’an, Shaanxi, 710054, PR ChinaKey Laboratory of Thermo-Fluid Science and Engineering, MOE, Xi’an Jiaotong University, Xi’an, Shaanxi, 710049, PR ChinaMine cooling and refrigeration system to deal with the heat hazard is well developed, but the mine air cooler which serves as the most important terminal equipment is relatively backward. The severe heat hazard and urgent cooling demand in deep underground mines necessitate further improvement of cooling capacity and effectiveness under strict requirements such as being compact, portable, nontoxic, and no-pollution. The thermoelectric (TE) energy conversion technology has great potential in cooling and miniaturization applications, which can meet the strict requirements of the underground mine cooling devices. Yet, a research gap exists in integrating TE energy conversion technology with the traditional air-cooling heat exchanger to the best of our knowledge. In this work, a hybrid utilization of TE and the helically coiled tube heat exchanger (HCEX) is proposed for air cooling at the working face of underground mine. The advantage of the TE-integrated HCEX lies in the combination of the heat transfer enhancement effect by secondary flow induced inside the helically coiled tube and the solid-state Peltier cooling effect by the TE module positioned on the external shell wall of the heat exchanger, which can potentially improve the air-cooling capacity without occupying large space. A numerical simulation of the fluid-thermal-electric multiphysics field is performed to investigate the cooling rate and the effectiveness of the TE-integrated HCEX. Results show that additional cooling power can be effectively provided by TE. As the filling ratio (FR) of TE module on the external shell wall increases from 50 to 100%, the air-cooling capacity continuously increases, performing better than that of the conventional HCEX. The effect of air inlet temperature and inlet velocity on the cooling performance is investigated for the best design of the TE-integrated HCEX with FR of 100%. When the inlet temperature of air increases from 303.15 to 313.15 K under constant inlet velocity, the cooling rate increases and cooling effectiveness decreases. Also, the cooling rate increases and the cooling effectiveness decreases when the inlet velocity of air increases from 10 to 25 m s−1 under constant inlet temperature. Within the simulated range of air inlet conditions in this work, the maximum total cooling rate Q c,total at optimal current of 6 A for the TE-integrated HCEX results in an enhancement of 49.8 to 35.0% compared to the conventional HCEX. The maximum cooling effectiveness at optimal current of 6 A is 21.73–26.49% for the TE-integrated HCEX, which is higher than the effectiveness of the conventional HCEX of 15.74–18.24%.https://doi.org/10.1515/phys-2025-0123thermoelectric coolinghelically coiled tube heat exchangerunderground mine air coolerfluid-thermal-electricmultiphysics numerical simulation
spellingShingle Lu Xing
Dai Renkun
Deng Jun
Ma Ting
Numerical investigation on fluid-thermal-electric performance of a thermoelectric-integrated helically coiled tube heat exchanger for coal mine air cooling
Open Physics
thermoelectric cooling
helically coiled tube heat exchanger
underground mine air cooler
fluid-thermal-electric
multiphysics numerical simulation
title Numerical investigation on fluid-thermal-electric performance of a thermoelectric-integrated helically coiled tube heat exchanger for coal mine air cooling
title_full Numerical investigation on fluid-thermal-electric performance of a thermoelectric-integrated helically coiled tube heat exchanger for coal mine air cooling
title_fullStr Numerical investigation on fluid-thermal-electric performance of a thermoelectric-integrated helically coiled tube heat exchanger for coal mine air cooling
title_full_unstemmed Numerical investigation on fluid-thermal-electric performance of a thermoelectric-integrated helically coiled tube heat exchanger for coal mine air cooling
title_short Numerical investigation on fluid-thermal-electric performance of a thermoelectric-integrated helically coiled tube heat exchanger for coal mine air cooling
title_sort numerical investigation on fluid thermal electric performance of a thermoelectric integrated helically coiled tube heat exchanger for coal mine air cooling
topic thermoelectric cooling
helically coiled tube heat exchanger
underground mine air cooler
fluid-thermal-electric
multiphysics numerical simulation
url https://doi.org/10.1515/phys-2025-0123
work_keys_str_mv AT luxing numericalinvestigationonfluidthermalelectricperformanceofathermoelectricintegratedhelicallycoiledtubeheatexchangerforcoalmineaircooling
AT dairenkun numericalinvestigationonfluidthermalelectricperformanceofathermoelectricintegratedhelicallycoiledtubeheatexchangerforcoalmineaircooling
AT dengjun numericalinvestigationonfluidthermalelectricperformanceofathermoelectricintegratedhelicallycoiledtubeheatexchangerforcoalmineaircooling
AT mating numericalinvestigationonfluidthermalelectricperformanceofathermoelectricintegratedhelicallycoiledtubeheatexchangerforcoalmineaircooling