Influence of implantation of a novel domestic prosthetic aortic valve on the functional class of heart failure one year after surgery

Aim. To assess the severity of heart failure (HF) 1 year after aortic valve replacement with a novel bioprosthetic valve with the “easy change” system.Material and methods. The study included 59 patients (24 men and 35 women) diagnosed with degenerative aortic valve disease without concomitant cardi...

Full description

Saved in:
Bibliographic Details
Main Authors: K. A. Petlin, E. А. Kosovskikh, Yu. N. Chernykh, B. N. Kozlov
Format: Article
Language:Russian
Published: «FIRMA «SILICEA» LLC 2022-09-01
Series:Российский кардиологический журнал
Subjects:
Online Access:https://russjcardiol.elpub.ru/jour/article/view/4829
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850030928103997440
author K. A. Petlin
E. А. Kosovskikh
Yu. N. Chernykh
B. N. Kozlov
author_facet K. A. Petlin
E. А. Kosovskikh
Yu. N. Chernykh
B. N. Kozlov
author_sort K. A. Petlin
collection DOAJ
description Aim. To assess the severity of heart failure (HF) 1 year after aortic valve replacement with a novel bioprosthetic valve with the “easy change” system.Material and methods. The study included 59 patients (24 men and 35 women) diagnosed with degenerative aortic valve disease without concomitant cardiac pathology. The mean age of the patients was 69,6±4,3 years. An assessment of NYHA HF class using six-minute walk test was carried out. The venous plasma level of N-terminal pro-brain natriuretric peptide (NT-proBNP) before and after surgery was also used to determine the severity of HF. In 31 patients (52,5%), NYHA class III HF was determined before surgery.Results. Comparative analysis of HF classes revealed a significant difference. Thus, after implantation of MedEng-BIO prosthetic aortic valve, the distance of the six-minute walk test increased by an average of 125 m (p=0,001). NT-proBNP level decreased from 162,2 pg/ml to 63,7 pg/ml (p=0,003).Conclusion. One-year follow-up of patients after implantation of a novel bioprosthetic aortic valve showed an objective decrease in the severity of HF according to six-minute walk test and NT-proBNP level in venous blood plasma.
format Article
id doaj-art-877eeeb509ff4b31812852ced83a79f4
institution DOAJ
issn 1560-4071
2618-7620
language Russian
publishDate 2022-09-01
publisher «FIRMA «SILICEA» LLC
record_format Article
series Российский кардиологический журнал
spelling doaj-art-877eeeb509ff4b31812852ced83a79f42025-08-20T02:59:06Zrus«FIRMA «SILICEA» LLCРоссийский кардиологический журнал1560-40712618-76202022-09-0127810.15829/1560-4071-2022-48293501Influence of implantation of a novel domestic prosthetic aortic valve on the functional class of heart failure one year after surgeryK. A. Petlin0E. А. Kosovskikh1Yu. N. Chernykh2B. N. Kozlov3Cardiology Research Institute, Tomsk National Research Medical CenterCardiology Research Institute, Tomsk National Research Medical CenterCardiology Research Institute, Tomsk National Research Medical CenterCardiology Research Institute, Tomsk National Research Medical CenterAim. To assess the severity of heart failure (HF) 1 year after aortic valve replacement with a novel bioprosthetic valve with the “easy change” system.Material and methods. The study included 59 patients (24 men and 35 women) diagnosed with degenerative aortic valve disease without concomitant cardiac pathology. The mean age of the patients was 69,6±4,3 years. An assessment of NYHA HF class using six-minute walk test was carried out. The venous plasma level of N-terminal pro-brain natriuretric peptide (NT-proBNP) before and after surgery was also used to determine the severity of HF. In 31 patients (52,5%), NYHA class III HF was determined before surgery.Results. Comparative analysis of HF classes revealed a significant difference. Thus, after implantation of MedEng-BIO prosthetic aortic valve, the distance of the six-minute walk test increased by an average of 125 m (p=0,001). NT-proBNP level decreased from 162,2 pg/ml to 63,7 pg/ml (p=0,003).Conclusion. One-year follow-up of patients after implantation of a novel bioprosthetic aortic valve showed an objective decrease in the severity of HF according to six-minute walk test and NT-proBNP level in venous blood plasma.https://russjcardiol.elpub.ru/jour/article/view/4829degenerative aortic valve diseaseheart failuresix-minute walk testbrain natriuretic peptide
spellingShingle K. A. Petlin
E. А. Kosovskikh
Yu. N. Chernykh
B. N. Kozlov
Influence of implantation of a novel domestic prosthetic aortic valve on the functional class of heart failure one year after surgery
Российский кардиологический журнал
degenerative aortic valve disease
heart failure
six-minute walk test
brain natriuretic peptide
title Influence of implantation of a novel domestic prosthetic aortic valve on the functional class of heart failure one year after surgery
title_full Influence of implantation of a novel domestic prosthetic aortic valve on the functional class of heart failure one year after surgery
title_fullStr Influence of implantation of a novel domestic prosthetic aortic valve on the functional class of heart failure one year after surgery
title_full_unstemmed Influence of implantation of a novel domestic prosthetic aortic valve on the functional class of heart failure one year after surgery
title_short Influence of implantation of a novel domestic prosthetic aortic valve on the functional class of heart failure one year after surgery
title_sort influence of implantation of a novel domestic prosthetic aortic valve on the functional class of heart failure one year after surgery
topic degenerative aortic valve disease
heart failure
six-minute walk test
brain natriuretic peptide
url https://russjcardiol.elpub.ru/jour/article/view/4829
work_keys_str_mv AT kapetlin influenceofimplantationofanoveldomesticprostheticaorticvalveonthefunctionalclassofheartfailureoneyearaftersurgery
AT eakosovskikh influenceofimplantationofanoveldomesticprostheticaorticvalveonthefunctionalclassofheartfailureoneyearaftersurgery
AT yunchernykh influenceofimplantationofanoveldomesticprostheticaorticvalveonthefunctionalclassofheartfailureoneyearaftersurgery
AT bnkozlov influenceofimplantationofanoveldomesticprostheticaorticvalveonthefunctionalclassofheartfailureoneyearaftersurgery