AIR SEBAGAI ALAT PENGENDALI IKLIM MIKRO DALAM BANGUNAN Studi Kasus : Taman Sari Royal Heritage Spa, Hotel Sheraton Mustika Yogyakarta

Indonesia is a country with wet tropical climate has constraints in obtaining thermal comfort because of the high air temperature, high air humidity and lower air speed. Modification of the microclimate might be conducted by increasing the cooling effect in a passive manner. Water can be used as one...

Full description

Saved in:
Bibliographic Details
Main Author: Dyah Hendrawati
Format: Article
Language:English
Published: Universitas Negeri Semarang 2016-07-01
Series:Jurnal Teknik Sipil dan Perencanaan
Subjects:
Online Access:https://journal.unnes.ac.id/nju/index.php/jtsp/article/view/7477
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850214717132374016
author Dyah Hendrawati
author_facet Dyah Hendrawati
author_sort Dyah Hendrawati
collection DOAJ
description Indonesia is a country with wet tropical climate has constraints in obtaining thermal comfort because of the high air temperature, high air humidity and lower air speed. Modification of the microclimate might be conducted by increasing the cooling effect in a passive manner. Water can be used as one of control strategy thermal to build the microclimate or to site. Water also played an important role in lowering temperature and raise humidity in a room in building.Taman Sari Royal Heritage Spa, which is located in Yogyakarta,is one of building that implementing water as thermal control by making pool in door. This research aims to understand the influence of water in controlling the micro climate and the anything influence it .This research uses the quantitative methods by conducting observation and measuring temperature and humidity directly to the research objects. Secondary data is needed in this research. There was also literature review on the stuff that supports research, and a literature study was also conducted. The research and analysis on the results shows that 1 .The room in Tamansari royal heritage spa still in comfort zone in thermal .2 .The volume of water affects temperatures and humidity room 3 .Distance is a significant factor.
format Article
id doaj-art-8646f9130e4e48f7919384415eba1aff
institution OA Journals
issn 1411-1772
2503-1899
language English
publishDate 2016-07-01
publisher Universitas Negeri Semarang
record_format Article
series Jurnal Teknik Sipil dan Perencanaan
spelling doaj-art-8646f9130e4e48f7919384415eba1aff2025-08-20T02:08:49ZengUniversitas Negeri SemarangJurnal Teknik Sipil dan Perencanaan1411-17722503-18992016-07-0118297106AIR SEBAGAI ALAT PENGENDALI IKLIM MIKRO DALAM BANGUNAN Studi Kasus : Taman Sari Royal Heritage Spa, Hotel Sheraton Mustika YogyakartaDyah Hendrawati0 Universitas Islam Indonesia (UII)Indonesia is a country with wet tropical climate has constraints in obtaining thermal comfort because of the high air temperature, high air humidity and lower air speed. Modification of the microclimate might be conducted by increasing the cooling effect in a passive manner. Water can be used as one of control strategy thermal to build the microclimate or to site. Water also played an important role in lowering temperature and raise humidity in a room in building.Taman Sari Royal Heritage Spa, which is located in Yogyakarta,is one of building that implementing water as thermal control by making pool in door. This research aims to understand the influence of water in controlling the micro climate and the anything influence it .This research uses the quantitative methods by conducting observation and measuring temperature and humidity directly to the research objects. Secondary data is needed in this research. There was also literature review on the stuff that supports research, and a literature study was also conducted. The research and analysis on the results shows that 1 .The room in Tamansari royal heritage spa still in comfort zone in thermal .2 .The volume of water affects temperatures and humidity room 3 .Distance is a significant factor.https://journal.unnes.ac.id/nju/index.php/jtsp/article/view/7477microclimatewaterthermalcomfort
spellingShingle Dyah Hendrawati
AIR SEBAGAI ALAT PENGENDALI IKLIM MIKRO DALAM BANGUNAN Studi Kasus : Taman Sari Royal Heritage Spa, Hotel Sheraton Mustika Yogyakarta
Jurnal Teknik Sipil dan Perencanaan
microclimate
water
thermalcomfort
title AIR SEBAGAI ALAT PENGENDALI IKLIM MIKRO DALAM BANGUNAN Studi Kasus : Taman Sari Royal Heritage Spa, Hotel Sheraton Mustika Yogyakarta
title_full AIR SEBAGAI ALAT PENGENDALI IKLIM MIKRO DALAM BANGUNAN Studi Kasus : Taman Sari Royal Heritage Spa, Hotel Sheraton Mustika Yogyakarta
title_fullStr AIR SEBAGAI ALAT PENGENDALI IKLIM MIKRO DALAM BANGUNAN Studi Kasus : Taman Sari Royal Heritage Spa, Hotel Sheraton Mustika Yogyakarta
title_full_unstemmed AIR SEBAGAI ALAT PENGENDALI IKLIM MIKRO DALAM BANGUNAN Studi Kasus : Taman Sari Royal Heritage Spa, Hotel Sheraton Mustika Yogyakarta
title_short AIR SEBAGAI ALAT PENGENDALI IKLIM MIKRO DALAM BANGUNAN Studi Kasus : Taman Sari Royal Heritage Spa, Hotel Sheraton Mustika Yogyakarta
title_sort air sebagai alat pengendali iklim mikro dalam bangunan studi kasus taman sari royal heritage spa hotel sheraton mustika yogyakarta
topic microclimate
water
thermalcomfort
url https://journal.unnes.ac.id/nju/index.php/jtsp/article/view/7477
work_keys_str_mv AT dyahhendrawati airsebagaialatpengendaliiklimmikrodalambangunanstudikasustamansariroyalheritagespahotelsheratonmustikayogyakarta