Improving respiratory rate monitoring in general wards following implementation of a rapid response system: a quality improvement initiative

Background Rapid response systems (RRSs) are widely implemented in hospitals to enhance patient safety. However, the successful activation of RRSs depends on the accurate identification of patient deterioration by ward nurses. Respiratory rate (RR) is a crucial vital sign for early detection of path...

Full description

Saved in:
Bibliographic Details
Main Authors: Noriko Sasaki, Yuichi Imanaka, Ayako Tsunemitsu, Osamu Hamada, Takahiko Tsutsumi
Format: Article
Language:English
Published: BMJ Publishing Group 2025-04-01
Series:BMJ Open Quality
Online Access:https://bmjopenquality.bmj.com/content/14/2/e003218.full
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850211478622175232
author Noriko Sasaki
Yuichi Imanaka
Ayako Tsunemitsu
Osamu Hamada
Takahiko Tsutsumi
author_facet Noriko Sasaki
Yuichi Imanaka
Ayako Tsunemitsu
Osamu Hamada
Takahiko Tsutsumi
author_sort Noriko Sasaki
collection DOAJ
description Background Rapid response systems (RRSs) are widely implemented in hospitals to enhance patient safety. However, the successful activation of RRSs depends on the accurate identification of patient deterioration by ward nurses. Respiratory rate (RR) is a crucial vital sign for early detection of pathological conditions, but it is often neglected or inaccurately recorded. This study aimed to improve RR measurement by nurses in general wards through a quality improvement (QI) project following the implementation of an RRS.Methods A QI project was conducted at a private acute care hospital in Japan from October 2022 to April 2024. The interventions were divided into three phases: (1) public announcements and educational activities, (2) implementation of an early warning system (EWS) and (3) modification of the inter-department handoff template. Interrupted time series analysis was used to evaluate the impact of the interventions on the daily proportion of RR measurements to total vital sign measurements (the total number of RR measurements/the total number of measurements of the traditional four vital signs: blood pressure, heart rate, body temperature and RR).Results A total of 14 864 patients were included in the study. The baseline proportion of RR measurements to total vital sign measurements was approximately 3%. The interventions led to a significant increase in RR measurement. In Phase 1, there was an immediate level change in the proportion of RR measurements to total vital sign measurements (incidence rate ratio (IRR) 1.148; 95% CI 1.075 to 1.226). In Phase 2, there was a further level change (IRR 2.113; 95% CI 1.963 to 2.275) and an increasing slope over time (IRR 1.002; 95% CI 1.002 to 1.003). In Phase 3, there was an additional level change (IRR 1.163; 95% CI 1.103 to 1.227) and an increasing slope (IRR 1.002; 95% CI 1.001 to 1.002).Conclusions A multifaceted approach, including educational activities, EWS integration and modification of inter-department handoff templates, significantly improved RR monitoring in general wards. The findings emphasise the importance of combining immediate educational interventions with long-term strategies such as behavioural nudges to sustain adherence to patient safety protocols.
format Article
id doaj-art-862f121eeed346f5ace5dd3a9ea9bd06
institution OA Journals
issn 2399-6641
language English
publishDate 2025-04-01
publisher BMJ Publishing Group
record_format Article
series BMJ Open Quality
spelling doaj-art-862f121eeed346f5ace5dd3a9ea9bd062025-08-20T02:09:33ZengBMJ Publishing GroupBMJ Open Quality2399-66412025-04-0114210.1136/bmjoq-2024-003218Improving respiratory rate monitoring in general wards following implementation of a rapid response system: a quality improvement initiativeNoriko Sasaki0Yuichi Imanaka1Ayako Tsunemitsu2Osamu Hamada3Takahiko Tsutsumi4Department of Healthcare Economics and Quality Management, Graduate School of Medicine, Kyoto University, Kyoto, JapanDepartment of Healthcare Economics and Quality Management, Graduate School of Medicine, Kyoto University, Kyoto, JapanDepartment of Healthcare Economics and Quality Management, Graduate School of Medicine, Kyoto University, Kyoto, JapanDepartment of General Internal Medicine, Aijinkai Inoue Hospital, Suita, JapanDepartment of Healthcare Economics and Quality Management, Graduate School of Medicine, Kyoto University, Kyoto, JapanBackground Rapid response systems (RRSs) are widely implemented in hospitals to enhance patient safety. However, the successful activation of RRSs depends on the accurate identification of patient deterioration by ward nurses. Respiratory rate (RR) is a crucial vital sign for early detection of pathological conditions, but it is often neglected or inaccurately recorded. This study aimed to improve RR measurement by nurses in general wards through a quality improvement (QI) project following the implementation of an RRS.Methods A QI project was conducted at a private acute care hospital in Japan from October 2022 to April 2024. The interventions were divided into three phases: (1) public announcements and educational activities, (2) implementation of an early warning system (EWS) and (3) modification of the inter-department handoff template. Interrupted time series analysis was used to evaluate the impact of the interventions on the daily proportion of RR measurements to total vital sign measurements (the total number of RR measurements/the total number of measurements of the traditional four vital signs: blood pressure, heart rate, body temperature and RR).Results A total of 14 864 patients were included in the study. The baseline proportion of RR measurements to total vital sign measurements was approximately 3%. The interventions led to a significant increase in RR measurement. In Phase 1, there was an immediate level change in the proportion of RR measurements to total vital sign measurements (incidence rate ratio (IRR) 1.148; 95% CI 1.075 to 1.226). In Phase 2, there was a further level change (IRR 2.113; 95% CI 1.963 to 2.275) and an increasing slope over time (IRR 1.002; 95% CI 1.002 to 1.003). In Phase 3, there was an additional level change (IRR 1.163; 95% CI 1.103 to 1.227) and an increasing slope (IRR 1.002; 95% CI 1.001 to 1.002).Conclusions A multifaceted approach, including educational activities, EWS integration and modification of inter-department handoff templates, significantly improved RR monitoring in general wards. The findings emphasise the importance of combining immediate educational interventions with long-term strategies such as behavioural nudges to sustain adherence to patient safety protocols.https://bmjopenquality.bmj.com/content/14/2/e003218.full
spellingShingle Noriko Sasaki
Yuichi Imanaka
Ayako Tsunemitsu
Osamu Hamada
Takahiko Tsutsumi
Improving respiratory rate monitoring in general wards following implementation of a rapid response system: a quality improvement initiative
BMJ Open Quality
title Improving respiratory rate monitoring in general wards following implementation of a rapid response system: a quality improvement initiative
title_full Improving respiratory rate monitoring in general wards following implementation of a rapid response system: a quality improvement initiative
title_fullStr Improving respiratory rate monitoring in general wards following implementation of a rapid response system: a quality improvement initiative
title_full_unstemmed Improving respiratory rate monitoring in general wards following implementation of a rapid response system: a quality improvement initiative
title_short Improving respiratory rate monitoring in general wards following implementation of a rapid response system: a quality improvement initiative
title_sort improving respiratory rate monitoring in general wards following implementation of a rapid response system a quality improvement initiative
url https://bmjopenquality.bmj.com/content/14/2/e003218.full
work_keys_str_mv AT norikosasaki improvingrespiratoryratemonitoringingeneralwardsfollowingimplementationofarapidresponsesystemaqualityimprovementinitiative
AT yuichiimanaka improvingrespiratoryratemonitoringingeneralwardsfollowingimplementationofarapidresponsesystemaqualityimprovementinitiative
AT ayakotsunemitsu improvingrespiratoryratemonitoringingeneralwardsfollowingimplementationofarapidresponsesystemaqualityimprovementinitiative
AT osamuhamada improvingrespiratoryratemonitoringingeneralwardsfollowingimplementationofarapidresponsesystemaqualityimprovementinitiative
AT takahikotsutsumi improvingrespiratoryratemonitoringingeneralwardsfollowingimplementationofarapidresponsesystemaqualityimprovementinitiative