Mechanical properties of GGBS-based polyethylene engineered cementitious composite (PE-ECC) at elevated temperature

Engineered Cementitious Composite (ECC) is known for its multiple cracking and significant strain-hardening behaviors. While polyethylene-based ECC (PE-ECC) has demonstrated superior structural performance at ambient temperature, its behavior under elevated temperature remains relatively underexplor...

Full description

Saved in:
Bibliographic Details
Main Authors: Fardin Mahmoudi, Jamal A. Abdalla, Rami A. Hawileh
Format: Article
Language:English
Published: Elsevier 2025-09-01
Series:Results in Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2590123025022315
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849717939596427264
author Fardin Mahmoudi
Jamal A. Abdalla
Rami A. Hawileh
author_facet Fardin Mahmoudi
Jamal A. Abdalla
Rami A. Hawileh
author_sort Fardin Mahmoudi
collection DOAJ
description Engineered Cementitious Composite (ECC) is known for its multiple cracking and significant strain-hardening behaviors. While polyethylene-based ECC (PE-ECC) has demonstrated superior structural performance at ambient temperature, its behavior under elevated temperature remains relatively underexplored. Additionally, ECC is characterized by high cement content. This study investigates the impact of both elevated temperatures and cement substitution with Ground Granulated Blast Furnace Slag (GGBS) at levels of 40 % and 60 % (denoted as G40 and G60, respectively) on the mechanical and micromechanical properties of GGBS-based High Strength and High Ductility (HSHD) PE-ECCs. Compression tests were conducted after heating up to 800 °C, while tensile and flexural tests were performed on specimens heated to 120 °C and 200 °C, respectively. The results indicated that the increase in GGBS from 40 % to 60 % correlated with a decrease in compressive strength. Specimens with 40 % GGBS replacement showed compressive strengths of 31.1 MPa and 23.2 MPa after temperature exposures of 600 °C and 800 °C, retaining 43.6 % and 32.5 % of the control samples’ strength, respectively. Additionally, empirical equations were derived to estimate the residual compressive strengths of PE-ECC specimens. All tensile samples heated up to 120 °C exhibited strain-hardening and multiple cracking behaviors, while those exposed to 200 °C failed brittlely after the first crack. In general, G40 showed higher tensile strength than G60, while G60 showed higher tensile strain at all temperatures. Prisms exhibited multiple cracking and deflection-hardening up to 120 °C. G40 specimens demonstrated higher flexural strengths across all temperature levels and exhibited greater deflection values than G60 at both room temperature and 120 °C.
format Article
id doaj-art-85e9367f437b43f78f4367b99aa8e158
institution DOAJ
issn 2590-1230
language English
publishDate 2025-09-01
publisher Elsevier
record_format Article
series Results in Engineering
spelling doaj-art-85e9367f437b43f78f4367b99aa8e1582025-08-20T03:12:31ZengElsevierResults in Engineering2590-12302025-09-012710615910.1016/j.rineng.2025.106159Mechanical properties of GGBS-based polyethylene engineered cementitious composite (PE-ECC) at elevated temperatureFardin Mahmoudi0Jamal A. Abdalla1Rami A. Hawileh2Department of Civil Engineering, American University of Sharjah, P.O. Box 26666, Sharjah, United Arab EmiratesCorresponding author.; Department of Civil Engineering, American University of Sharjah, P.O. Box 26666, Sharjah, United Arab EmiratesDepartment of Civil Engineering, American University of Sharjah, P.O. Box 26666, Sharjah, United Arab EmiratesEngineered Cementitious Composite (ECC) is known for its multiple cracking and significant strain-hardening behaviors. While polyethylene-based ECC (PE-ECC) has demonstrated superior structural performance at ambient temperature, its behavior under elevated temperature remains relatively underexplored. Additionally, ECC is characterized by high cement content. This study investigates the impact of both elevated temperatures and cement substitution with Ground Granulated Blast Furnace Slag (GGBS) at levels of 40 % and 60 % (denoted as G40 and G60, respectively) on the mechanical and micromechanical properties of GGBS-based High Strength and High Ductility (HSHD) PE-ECCs. Compression tests were conducted after heating up to 800 °C, while tensile and flexural tests were performed on specimens heated to 120 °C and 200 °C, respectively. The results indicated that the increase in GGBS from 40 % to 60 % correlated with a decrease in compressive strength. Specimens with 40 % GGBS replacement showed compressive strengths of 31.1 MPa and 23.2 MPa after temperature exposures of 600 °C and 800 °C, retaining 43.6 % and 32.5 % of the control samples’ strength, respectively. Additionally, empirical equations were derived to estimate the residual compressive strengths of PE-ECC specimens. All tensile samples heated up to 120 °C exhibited strain-hardening and multiple cracking behaviors, while those exposed to 200 °C failed brittlely after the first crack. In general, G40 showed higher tensile strength than G60, while G60 showed higher tensile strain at all temperatures. Prisms exhibited multiple cracking and deflection-hardening up to 120 °C. G40 specimens demonstrated higher flexural strengths across all temperature levels and exhibited greater deflection values than G60 at both room temperature and 120 °C.http://www.sciencedirect.com/science/article/pii/S2590123025022315Polyethylene (PE) fiberEngineered cementitious composites (ECC)Mechanical propertiesElevated temperatureGround granulated blast furnace slag (GGBS)
spellingShingle Fardin Mahmoudi
Jamal A. Abdalla
Rami A. Hawileh
Mechanical properties of GGBS-based polyethylene engineered cementitious composite (PE-ECC) at elevated temperature
Results in Engineering
Polyethylene (PE) fiber
Engineered cementitious composites (ECC)
Mechanical properties
Elevated temperature
Ground granulated blast furnace slag (GGBS)
title Mechanical properties of GGBS-based polyethylene engineered cementitious composite (PE-ECC) at elevated temperature
title_full Mechanical properties of GGBS-based polyethylene engineered cementitious composite (PE-ECC) at elevated temperature
title_fullStr Mechanical properties of GGBS-based polyethylene engineered cementitious composite (PE-ECC) at elevated temperature
title_full_unstemmed Mechanical properties of GGBS-based polyethylene engineered cementitious composite (PE-ECC) at elevated temperature
title_short Mechanical properties of GGBS-based polyethylene engineered cementitious composite (PE-ECC) at elevated temperature
title_sort mechanical properties of ggbs based polyethylene engineered cementitious composite pe ecc at elevated temperature
topic Polyethylene (PE) fiber
Engineered cementitious composites (ECC)
Mechanical properties
Elevated temperature
Ground granulated blast furnace slag (GGBS)
url http://www.sciencedirect.com/science/article/pii/S2590123025022315
work_keys_str_mv AT fardinmahmoudi mechanicalpropertiesofggbsbasedpolyethyleneengineeredcementitiouscompositepeeccatelevatedtemperature
AT jamalaabdalla mechanicalpropertiesofggbsbasedpolyethyleneengineeredcementitiouscompositepeeccatelevatedtemperature
AT ramiahawileh mechanicalpropertiesofggbsbasedpolyethyleneengineeredcementitiouscompositepeeccatelevatedtemperature